Classic heat pumps
18 certified models, ranked by seasonal cooling efficiency (SEER2), then heating efficiency (HSPF2), highest first.
Filters
Filters
Classic
The list
-
1 MC4VHC18SClassic20,000 Btu/h5.86 kWheating at 47°F 18,000 Btu/h5.28 kWcooling at 95°F
-
2 MMRSHC27AS3Classic28,000 Btu/h8.21 kWheating at 47°F 27,400 Btu/h8.03 kWcooling at 95°F
-
3 GRH32IC18ASClassic18,500 Btu/h5.42 kWheating at 47°F 18,000 Btu/h5.28 kWcooling at 95°F
-
4 GRH32IC12ASClassic12,000 Btu/h3.52 kWheating at 47°F 12,000 Btu/h3.52 kWcooling at 95°F
-
5 GRH32IC12ASAClassic12,000 Btu/h3.52 kWheating at 47°F 12,000 Btu/h3.52 kWcooling at 95°F
-
6 MRSVHC24ASClassic25,000 Btu/h7.33 kWheating at 47°F 24,000 Btu/h7.03 kWcooling at 95°F
-
7 MMRSHC48AS5Classic48,000 Btu/h14.07 kWheating at 47°F 48,000 Btu/h14.07 kWcooling at 95°F
-
8 GRH32IC36ASClassic34,000 Btu/h9.96 kWheating at 47°F 33,600 Btu/h9.85 kWcooling at 95°F
-
9 MRPOC30ASClassic30,000 Btu/h8.79 kWheating at 47°F 30,000 Btu/h8.79 kWcooling at 95°F
-
10 MRSVHC18ASClassic20,000 Btu/h5.86 kWheating at 47°F 17,000 Btu/h4.98 kWcooling at 95°F
-
11 MMRSHC18AS2Classic19,000 Btu/h5.57 kWheating at 47°F 18,000 Btu/h5.28 kWcooling at 95°F
-
12 MMRSHC36AS4Classic37,000 Btu/h10.84 kWheating at 47°F 36,000 Btu/h10.55 kWcooling at 95°F
-
13 MRSVHC12ASClassic12,000 Btu/h3.52 kWheating at 47°F 11,500 Btu/h3.37 kWcooling at 95°F
-
14 GMRSHC42AS5Classic42,000 Btu/h12.31 kWheating at 47°F 42,000 Btu/h12.31 kWcooling at 95°F
-
15 GMRSHC36AS4Classic36,000 Btu/h10.55 kWheating at 47°F 36,000 Btu/h10.55 kWcooling at 95°F
-
16 GMRSHC24AS3Classic24,000 Btu/h7.03 kWheating at 47°F 24,000 Btu/h7.03 kWcooling at 95°F
-
17 GMRSHC18AS2Classic18,000 Btu/h5.28 kWheating at 47°F 18,000 Btu/h5.28 kWcooling at 95°F
-
18 MRSVHC48ASClassic50,000 Btu/h14.65 kWheating at 47°F 48,000 Btu/h14.07 kWcooling at 95°F
| # | Model | Brands | Type | Size | At 5°FBtu/hkW · heating | At 47°FBtu/hkW · heating | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | SEER2median pairing | HSPF2Btu/Wh · median pairing | Compressor | Refrigerant | Market | Pairings |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | MC4VHC18S | Classic | Mini-split | 18,000 Btu (1.5-ton) | 13,0003.81 | 20,0005.86 | 18,0005.28 | 65% | 2.08 | 23.0 | 10.0 | Variable | R-410A | US CA | 1 |
| 2 | MMRSHC27AS3 | Classic | Mini-split | 30,000 Btu (2.5-ton) | 18,8005.51 | 28,0008.21 | 27,4008.03 | 67–68% | 2.00 | 22.3 | 9.2 | Variable | R-410A | US CA | 3 |
| 3 | GRH32IC18AS | Classic | Mini-split | 18,000 Btu (1.5-ton) | 13,0003.81 | 18,5005.42 | 18,0005.28 | 70% | 1.90 | 21.5 | 8.5 | Variable | R-32 | US CA | 1 |
| 4 | GRH32IC12AS | Classic | Mini-split | 12,000 Btu (1-ton) | 9,4002.75 | 12,0003.52 | 12,0003.52 | 78% | 1.90 | 21.5 | 8.5 | Variable | R-32 | US CA | 1 |
| 5 | GRH32IC12ASA | Classic | Mini-split | 12,000 Btu (1-ton) | 8,5002.49 | 12,0003.52 | 12,0003.52 | 71% | 1.90 | 21.5 | 8.5 | Variable | R-32 | US CA | 1 |
| 6 | MRSVHC24AS | Classic | Mini-split | 24,000 Btu (2-ton) | 18,5005.42 | 25,0007.33 | 24,0007.03 | 74–80% | 2.20 | 21.2 | 10.3 | Variable | R-410A | US CA | 3 |
| 7 | MMRSHC48AS5 | Classic | Mini-split | 48,000 Btu (4-ton) | 33,0009.67 | 48,00014.07 | 48,00014.07 | 69% | 1.80 | 21.1 | 9.5 | Variable | R-410A | US CA | 1 |
| 8 | GRH32IC36AS | Classic | Mini-split | 36,000 Btu (3-ton) | 23,4006.86 | 34,0009.96 | 33,6009.85 | 69–72% | 1.85 | 21.0 | 8.5 | Variable | R-32 | US CA | 2 |
| 9 | MRPOC30AS | Classic | Mini-split | 30,000 Btu (2.5-ton) | 18,4005.39 | 30,0008.79 | 30,0008.79 | 61% | 1.86 | 21.0 | 8.2 | Variable | R-410A | US CA | 2 |
| 10 | MRSVHC18AS | Classic | Mini-split | 18,000 Btu (1.5-ton) | 13,0003.81 | 20,0005.86 | 17,0004.98 | 65–67% | 2.40 | 20.0 | 10.6 | Variable | R-410A | US CA | 3 |
| 11 | MMRSHC18AS2 | Classic | Mini-split | 18,000 Btu (1.5-ton) | 12,9003.78 | 19,0005.57 | 18,0005.28 | 66–70% | 2.00 | 20.0 | 10.0 | Variable | R-410A | US CA | 3 |
| 12 | MMRSHC36AS4 | Classic | Mini-split | 36,000 Btu (3-ton) | 24,0007.03 | 37,00010.84 | 36,00010.55 | 65% | 1.68 | 20.0 | 9.2 | Variable | R-410A | US CA | 1 |
| 13 | MRSVHC12AS | Classic | Mini-split | 12,000 Btu (1-ton) | 8,4002.46 | 12,0003.52 | 11,5003.37 | 67–70% | 2.26 | 19.0 | 10.3 | Variable | R-410A | US CA | 3 |
| 14 | GMRSHC42AS5 | Classic | Mini-split | 42,000 Btu (3.5-ton) | 37,00010.84 | 42,00012.31 | 42,00012.31 | 86–90% | 1.90 | 19.0 | 9.0 | Variable | R-32 | US CA | 3 |
| 15 | GMRSHC36AS4 | Classic | Mini-split | 36,000 Btu (3-ton) | 34,0009.96 | 36,00010.55 | 36,00010.55 | 92–100% | 1.90 | 19.0 | 9.0 | Variable | R-32 | US CA | 3 |
| 16 | GMRSHC24AS3 | Classic | Mini-split | 24,000 Btu (2-ton) | 21,6006.33 | 24,0007.03 | 24,0007.03 | 90% | 1.86 | 19.0 | 9.0 | Variable | R-32 | US CA | 3 |
| 17 | GMRSHC18AS2 | Classic | Mini-split | 18,000 Btu (1.5-ton) | 13,7004.02 | 18,0005.28 | 18,0005.28 | 76–77% | 1.86 | 19.0 | 9.0 | Variable | R-32 | US CA | 3 |
| 18 | MRSVHC48AS | Classic | Mini-split | 48,000 Btu (4-ton) | 35,00010.26 | 50,00014.65 | 48,00014.07 | 70% | 1.85 | 18.9 | 10.0 | Variable | R-410A | US CA | 1 |
18 of 18 units
Other sizes
Every size class, with how many units it holds and its median heat output at 5°F