Central heat pumps
2,996 certified units by size, with the heat each size is certified to deliver at 5°F. Pick the size on your quote.
Central means ducted: split systems and packaged units.
By size
| Btunominal size · cooling | Tons | Units | Median heat at 47°FBtu/hkW · heating | Median heat at 5°FBtu/hkW · full speed | Median cold output% of 47°F rating |
|---|---|---|---|---|---|
| 6,000 | 0.5 | 134 | 8,2002.40 | 5,9001.73 | 72% |
| 9,000 | 0.75 | 35 | 9,0002.64 | 5,6001.64 | 62% |
| 12,000 | 1 | 40 | 14,2004.16 | 8,2002.40 | 58% |
| 18,000 | 1.5 | 339 | 18,0005.28 | 13,0003.81 | 72% |
| 24,000 | 2 | 674 | 24,0007.03 | 19,4005.69 | 77% |
| 30,000 | 2.5 | 399 | 30,0008.79 | 21,3506.26 | 70% |
| 36,000 | 3 | 601 | 35,40010.37 | 27,0007.91 | 76% |
| 42,000 | 3.5 | 291 | 44,00012.90 | 33,0009.67 | 70% |
| 48,000 | 4 | 588 | 48,00014.07 | 38,00011.14 | 75% |
| 54,000whole class | 4.5 | 484 | 56,00016.41 | 40,00011.72 | 72% |
| 60,000 | 5 | 36 | 56,00016.41 | 28,7008.41 | 52% |