Heat Pump List

Tools

Coast Air heat pumps

9 certified models, ranked by seasonal cooling efficiency (SEER2), then heating efficiency (HSPF2), highest first.

Filters

Filters Coast Air

The list

  1. 1 A-CAD09-0ACoast Air
    9,900 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 6,400 Btu/h · Cold output 65% · HSPF2 10.8 · 1 pairing

  2. 2 A-CAD09-0BCoast Air
    10,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 7,300 Btu/h · Cold output 73% · HSPF2 11.5 · 1 pairing

  3. 3 A-CAD12-0BCoast Air
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 8,400 Btu/h · Cold output 70% · HSPF2 10.2 · 1 pairing

  4. 4 A-CAD18-1ACoast Air
    18,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 11,700 Btu/h · Cold output 65% · HSPF2 9.8 · 1 pairing

  5. 5 A-CAD24-1BCoast Air
    24,000 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 16,100 Btu/h · Cold output 67% · HSPF2 9.5 · 1 pairing

  6. 6 A-CAD18-1BCoast Air
    18,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 12,800 Btu/h · Cold output 71% · HSPF2 11.5 · 1 pairing

  7. 7 A-CAD12-0ACoast Air
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 6,400 Btu/h · Cold output 53% · HSPF2 9.0 · 1 pairing

  8. 8 A-CAD12-0Coast Air
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 46,000 Btu/h · Cold output 383% · HSPF2 7.7 · 1 pairing

  9. 9 A-CAD24-1ACoast Air
    25,000 Btu/hheating at 47°F 23,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 15,500 Btu/h · Cold output 62% · HSPF2 9.2 · 1 pairing

Coast Air heat pumps, ranked by seasonal cooling efficiency (SEER2), then heating efficiency (HSPF2)
# Model Brands Type Size At 5°FBtu/h · heating At 47°FBtu/h · heating At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed SEER2median pairing HSPF2Btu/Wh · median pairing Compressor Refrigerant Market Pairings
1 A-CAD09-0A Coast Air Mini-split 9,000 Btu6,400 9,900 9,000 65% 1.96 25.0 10.8 Variable R-410A US CA 1
2 A-CAD09-0B Coast Air Mini-split 9,000 Btu7,300 10,000 9,000 73% 2.17 23.6 11.5 Variable R-454B US CA 1
3 A-CAD12-0B Coast Air Mini-split 12,000 Btu (1-ton)8,400 12,000 12,000 70% 2.08 23.5 10.2 Variable R-454B US CA 1
4 A-CAD18-1A Coast Air Mini-split 18,000 Btu (1.5-ton)11,700 18,000 18,000 65% 2.05 22.7 9.8 Variable R-410A US CA 1
5 A-CAD24-1B Coast Air Mini-split 24,000 Btu (2-ton)16,100 24,000 24,000 67% 2.00 22.7 9.5 Variable R-454B US CA 1
6 A-CAD18-1B Coast Air Mini-split 18,000 Btu (1.5-ton)12,800 18,000 18,000 71% 2.44 22.5 11.5 Variable R-454B US CA 1
7 A-CAD12-0A Coast Air Mini-split 12,000 Btu (1-ton)6,400 12,000 12,000 53% 1.96 22.5 9.0 Variable R-410A US CA 1
8 A-CAD12-0 Coast Air Mini-split 12,000 Btu (1-ton)46,000 12,000 12,000 383% 2.02 20.9 7.7 Variable R-410A US CA 1
9 A-CAD24-1A Coast Air Mini-split 24,000 Btu (2-ton)15,500 25,000 23,000 62% 2.04 20.5 9.2 Variable R-410A US CA 1

The share is heat output at 5°F divided by the 47°F rating. Tests use different compressor speeds.

9 of 9 units

Other sizes

Every size class, with how many units it holds and its median heat output at 5°F