31 certified models, ranked by seasonal cooling efficiency (SEER2), then heating efficiency (HSPF2), highest first.

Filters

Filters HaxxAir

The list

  1. 1 HVHZ-09A2UHaxxAir
    12,200 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 12,200 Btu/h · Cold output 100% · HSPF2 11.8 · 1 pairing

  2. 2 HVHZ-12A2UHaxxAir
    12,200 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 12,200 Btu/h · Cold output 100% · HSPF2 11.8 · 1 pairing

  3. 3 HVHZ-15A2UHaxxAir
    15,200 Btu/hheating at 47°F 15,000 Btu/hcooling at 95°F

    15,000 Btu · Mini-split · 5°F 12,200 Btu/h · Cold output 80% · HSPF2 11.1 · 1 pairing

  4. 4 HVHZ-09V2DHaxxAir
    9,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 9,000 Btu/h · Cold output 100% · HSPF2 11.0 · 1 pairing

  5. 5 HVHZ-12V2DHaxxAir
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 11,000 Btu/h · Cold output 92% · HSPF2 10.0 · 1 pairing

  6. 6 HVHZ-24V2DHaxxAir
    24,000 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 19,800 Btu/h · Cold output 83% · HSPF2 9.5 · 1 pairing

  7. 7 HVH-18T2DHaxxAir
    18,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 12,700 Btu/h · Cold output 71% · HSPF2 8.6 · 1 pairing

  8. 8 HAH-09T2DHaxxAir
    9,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 6,300 Btu/h · Cold output 70% · HSPF2 9.0 · 1 pairing

  9. 9 HVH-09T2DHaxxAir
    9,000 Btu/hheating at 47°F 9,000 Btu/hcooling at 95°F

    9,000 Btu · Mini-split · 5°F 6,300 Btu/h · Cold output 70% · HSPF2 9.0 · 1 pairing

  10. 10 HVHM-24T2DHaxxAir
    24,000 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 24,000 Btu/h · Cold output 100% · HSPF2 8.8 · 3 pairings

  11. 11 HVHSC-18T2DHaxxAir
    18,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 13,200 Btu/h · Cold output 73–74% · HSPF2 9.8 · 2 pairings

  12. 12 HVHZ-18V2DHaxxAir
    18,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 18,000 Btu/h · Cold output 100% · HSPF2 10.0 · 1 pairing

  13. 13 HVH-12T2DHaxxAir
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 8,400 Btu/h · Cold output 70% · HSPF2 9.5 · 1 pairing

  14. 14 HVHSC-12T2DHaxxAir
    12,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 8,500 Btu/h · Cold output 71% · HSPF2 9.3 · 2 pairings

  15. 15 HVHMZ-36V2DHaxxAir
    36,000 Btu/hheating at 47°F 36,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Mini-split · 5°F 34,200 Btu/h · Cold output 90–100% · HSPF2 9.5 · 3 pairings

  16. 16 HVHMZ-27V2DHaxxAir
    27,000 Btu/hheating at 47°F 27,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 26,600 Btu/h · Cold output 98–100% · HSPF2 9.4 · 3 pairings

  17. 17 HAH-24T2DHaxxAir
    23,000 Btu/hheating at 47°F 23,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 18,000 Btu/h · Cold output 78% · HSPF2 8.6 · 1 pairing

  18. 18 HVH-24T2DHaxxAir
    23,000 Btu/hheating at 47°F 23,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 18,000 Btu/h · Cold output 78% · HSPF2 8.6 · 1 pairing

  19. 19 HVHM-36T2DHaxxAir
    32,000 Btu/hheating at 47°F 32,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Mini-split · 5°F 36,000 Btu/h · Cold output 113% · HSPF2 9.0 · 3 pairings

  20. 20 HVHM-18T2DHaxxAir
    18,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 18,000 Btu/h · Cold output 100% · HSPF2 9.5 · 5 pairings

  21. 21 HVHMZ-42V2DHaxxAir
    46,500 Btu/hheating at 47°F 42,000 Btu/hcooling at 95°F

    42,000 Btu (3.5-ton) · Mini-split · 5°F 35,000 Btu/h · Cold output 75–76% · HSPF2 9.2 · 3 pairings

  22. 22 HVHMZ-18V2DHaxxAir
    18,000 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 17,400 Btu/h · Cold output 94–100% · HSPF2 9.7 · 3 pairings

  23. 23 HVHM-42T2DHaxxAir
    41,000 Btu/hheating at 47°F 41,000 Btu/hcooling at 95°F

    42,000 Btu (3.5-ton) · Mini-split · 5°F 36,000 Btu/h · Cold output 86–88% · HSPF2 8.9 · 3 pairings

  24. 24 HVHSC-24T2DHaxxAir
    24,000 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 19,000 Btu/h · Cold output 79% · HSPF2 10.0 · 1 pairing

  25. 25 HVHD-36E2D2HaxxAir
    34,000 Btu/hheating at 47°F 34,000 Btu/hcooling at 95°F

    36,000 Btu (3-ton) · Central · 5°F 26,000 Btu/h · Cold output 76% · HSPF2 9.5 · 1 pairing

  26. 26 HVHDZ-36V2DHaxxAir
    34,000 Btu/hheating at 47°F 34,000 Btu/hcooling at 95°F

    30,000 Btu (2.5-ton) · Central · 5°F 27,000 Btu/h · Cold output 79–97% · HSPF2 9.4 · 2 pairings

  27. 27 HVHDZ-24V2DHaxxAir
    24,000 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Central · 5°F 20,800 Btu/h · Cold output 87–88% · HSPF2 9.1 · 2 pairings

  28. 28 HVHDZ-48V2DHaxxAir
    48,000 Btu/hheating at 47°F 48,000 Btu/hcooling at 95°F

    48,000 Btu (4-ton) · Central · 5°F 34,000 Btu/h · Cold output 71–77% · HSPF2 8.7 · 2 pairings

  29. 29 HVHDZ-60V2DHaxxAir
    54,000 Btu/hheating at 47°F 54,000 Btu/hcooling at 95°F

    54,000 Btu (4.5-ton) · Central · 5°F 38,000 Btu/h · Cold output 70–74% · HSPF2 8.6 · 2 pairings

  30. 30 HVHD-48E2D2HaxxAir
    47,000 Btu/hheating at 47°F 48,000 Btu/hcooling at 95°F

    48,000 Btu (4-ton) · Central · 5°F 33,000 Btu/h · Cold output 70% · HSPF2 8.5 · 1 pairing

  31. 31 HVHD-24E2D2HaxxAir
    22,000 Btu/hheating at 47°F 22,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Central · 5°F 16,900 Btu/h · Cold output 77% · HSPF2 9.0 · 1 pairing

HaxxAir heat pumps, ranked by seasonal cooling efficiency (SEER2), then heating efficiency (HSPF2)
# Model Brands Type Size At 5°FBtu/h · heating At 47°FBtu/h · heating At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed SEER2median pairing HSPF2Btu/Wh · median pairing Compressor Refrigerant Market Pairings
1 HVHZ-09A2U HaxxAir Mini-split 9,000 Btu12,200 12,200 9,000 100% 2.25 32.0 11.8 Variable R-454B CA 1
2 HVHZ-12A2U HaxxAir Mini-split 12,000 Btu (1-ton)12,200 12,200 12,000 100% 2.25 30.0 11.8 Variable R-454B CA 1
3 HVHZ-15A2U HaxxAir Mini-split 15,000 Btu12,200 15,200 15,000 80% 2.25 25.6 11.1 Variable R-454B CA 1
4 HVHZ-09V2D HaxxAir Mini-split 9,000 Btu9,000 9,000 9,000 100% 2.10 25.0 11.0 Variable R-454B CA 1
5 HVHZ-12V2D HaxxAir Mini-split 12,000 Btu (1-ton)11,000 12,000 12,000 92% 2.00 23.0 10.0 Variable R-454B CA 1
6 HVHZ-24V2D HaxxAir Mini-split 24,000 Btu (2-ton)19,800 24,000 24,000 83% 1.80 22.5 9.5 Variable R-454B CA 1
7 HVH-18T2D HaxxAir Mini-split 18,000 Btu (1.5-ton)12,700 18,000 18,000 71% 1.80 22.5 8.6 Variable R-410A CA 1
8 HAH-09T2D HaxxAir Mini-split 9,000 Btu6,300 9,000 9,000 70% 1.80 22.0 9.0 Variable R-410A CA 1
9 HVH-09T2D HaxxAir Mini-split 9,000 Btu6,300 9,000 9,000 70% 1.80 22.0 9.0 Variable R-410A CA 1
10 HVHM-24T2D HaxxAir Mini-split 24,000 Btu (2-ton)24,000 24,000 24,000 100% 1.84 21.5 8.8 Variable R-410A CA 3
11 HVHSC-18T2D HaxxAir Mini-split 18,000 Btu (1.5-ton)13,200 18,000 18,000 73–74% 2.33 21.3 9.8 Variable R-410A CA 2
12 HVHZ-18V2D HaxxAir Mini-split 18,000 Btu (1.5-ton)18,000 18,000 18,000 100% 1.90 21.0 10.0 Variable R-454B CA 1
13 HVH-12T2D HaxxAir Mini-split 12,000 Btu (1-ton)8,400 12,000 12,000 70% 1.75 21.0 9.5 Variable R-410A CA 1
14 HVHSC-12T2D HaxxAir Mini-split 12,000 Btu (1-ton)8,500 12,000 12,000 71% 2.09 21.0 9.3 Variable R-410A CA 2
15 HVHMZ-36V2D HaxxAir Mini-split 36,000 Btu (3-ton)34,200 36,000 36,000 90–100% 1.87 20.5 9.5 Variable R-454B CA 3
16 HVHMZ-27V2D HaxxAir Mini-split 24,000 Btu (2-ton)26,600 27,000 27,000 98–100% 1.82 20.5 9.4 Variable R-454B CA 3
17 HAH-24T2D HaxxAir Mini-split 24,000 Btu (2-ton)18,000 23,000 23,000 78% 1.75 20.5 8.6 Variable R-410A CA 1
18 HVH-24T2D HaxxAir Mini-split 24,000 Btu (2-ton)18,000 23,000 23,000 78% 1.75 20.5 8.6 Variable R-410A CA 1
19 HVHM-36T2D HaxxAir Mini-split 30,000 Btu (2.5-ton)36,000 32,000 32,000 113% 1.84 20.3 9.0 Variable R-410A CA 3
20 HVHM-18T2D HaxxAir Mini-split 18,000 Btu (1.5-ton)18,000 18,000 18,000 100% 1.84 20.0 9.5 Variable R-410A CA 5
21 HVHMZ-42V2D HaxxAir Mini-split 42,000 Btu (3.5-ton)35,000 46,500 42,000 75–76% 1.87 20.0 9.2 Variable R-454B CA 3
22 HVHMZ-18V2D HaxxAir Mini-split 18,000 Btu (1.5-ton)17,400 18,000 18,000 94–100% 1.96 19.8 9.7 Variable R-454B CA 3
23 HVHM-42T2D HaxxAir Mini-split 42,000 Btu (3.5-ton)36,000 41,000 41,000 86–88% 1.84 19.0 8.9 Variable R-410A CA 3
24 HVHSC-24T2D HaxxAir Mini-split 24,000 Btu (2-ton)19,000 24,000 24,000 79% 2.20 18.5 10.0 Variable R-410A CA 1
25 HVHD-36E2D2 HaxxAir Central 36,000 Btu (3-ton)26,000 34,000 34,000 76% 2.05 18.0 9.5 Variable R-410A CA 1
26 HVHDZ-36V2D HaxxAir Central 30,000 Btu (2.5-ton)27,000 34,000 34,000 79–97% 1.98 18.0 9.4 Variable R-454B CA 2
27 HVHDZ-24V2D HaxxAir Central 24,000 Btu (2-ton)20,800 24,000 24,000 87–88% 2.13 18.0 9.1 Variable R-454B CA 2
28 HVHDZ-48V2D HaxxAir Central 48,000 Btu (4-ton)34,000 48,000 48,000 71–77% 2.21 17.8 8.7 Variable R-454B CA 2
29 HVHDZ-60V2D HaxxAir Central 54,000 Btu (4.5-ton)38,000 54,000 54,000 70–74% 2.23 17.7 8.6 Variable R-454B CA 2
30 HVHD-48E2D2 HaxxAir Central 48,000 Btu (4-ton)33,000 47,000 48,000 70% 1.90 17.5 8.5 Variable R-410A CA 1
31 HVHD-24E2D2 HaxxAir Central 24,000 Btu (2-ton)16,900 22,000 22,000 77% 2.05 16.5 9.0 Variable R-410A CA 1

The share is heat output at 5°F divided by the 47°F rating. Tests use different compressor speeds.

31 of 31 units

Other sizes

Every size class, with how many units it holds and its median heat output at 5°F