Heat Pump List

Tools

Sharp heat pumps

17 certified models, ranked by seasonal cooling efficiency (SEER2), then heating efficiency (HSPF2), highest first.

Filters

Filters Sharp

The list

  1. 1 AE-X18CHUSharp
    21,600 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 19,500 Btu/h · Cold output 90% · HSPF2 11.5 · 1 pairing

  2. 2 AE-X18ZHUSharp
    21,600 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 19,500 Btu/h · Cold output 90% · HSPF2 11.5 · 1 pairing

  3. 3 AE-X12CHUSharp
    16,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 16,000 Btu/h · Cold output 100% · HSPF2 11.0 · 2 pairings

  4. 4 AE-X12ZHU1Sharp
    16,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 16,000 Btu/h · Cold output 100% · HSPF2 11.0 · 1 pairing

  5. 16,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Central · 5°F 16,000 Btu/h · Cold output 100% · HSPF2 11.0 · 1 pairing

  6. 6 AE-X3M24BUSharp
    26,000 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 21,200 Btu/h · Cold output 82% · HSPF2 11.5 · 1 pairing

  7. 7 AE-X3M24CUSharp

    Same as AE-X3M24BU

    26,000 Btu/hheating at 47°F 24,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 21,200 Btu/h · Cold output 82% · HSPF2 11.5 · 1 pairing

  8. 8 AE-X18CUSharp
    21,600 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 19,000 Btu/h · Cold output 88% · HSPF2 11.0 · 2 pairings

  9. 9 AE-X18ZU1Sharp
    21,600 Btu/hheating at 47°F 18,000 Btu/hcooling at 95°F

    18,000 Btu (1.5-ton) · Mini-split · 5°F 18,000 Btu/h · Cold output 83% · HSPF2 11.0 · 2 pairings

  10. 10 AE-X12DWUSharp
    16,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 15,500 Btu/h · Cold output 97% · HSPF2 11.0 · 1 pairing

  11. 11 AE-X15CUSharp
    18,000 Btu/hheating at 47°F 15,000 Btu/hcooling at 95°F

    15,000 Btu · Mini-split · 5°F 15,300 Btu/h · Cold output 85% · HSPF2 11.0 · 2 pairings

  12. 12 AE-X15ZU1Sharp
    18,000 Btu/hheating at 47°F 15,000 Btu/hcooling at 95°F

    15,000 Btu · Mini-split · 5°F 15,300 Btu/h · Cold output 85% · HSPF2 11.0 · 2 pairings

  13. 13 AE-X24CUSharp
    24,000 Btu/hheating at 47°F 22,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 19,000 Btu/h · Cold output 79% · HSPF2 11.0 · 1 pairing

  14. 14 AE-X24ZU1Sharp
    24,000 Btu/hheating at 47°F 22,000 Btu/hcooling at 95°F

    24,000 Btu (2-ton) · Mini-split · 5°F 19,000 Btu/h · Cold output 79% · HSPF2 11.0 · 1 pairing

  15. 15 AE-X12CUSharp
    14,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 12,700 Btu/h · Cold output 91% · HSPF2 11.0 · 1 pairing

  16. 16 AE-X12ZU1Sharp
    14,000 Btu/hheating at 47°F 12,000 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 12,000 Btu/h · Cold output 86% · HSPF2 11.0 · 1 pairing

  17. 17 AE-X12CPUSharp
    14,000 Btu/hheating at 47°F 12,500 Btu/hcooling at 95°F

    12,000 Btu (1-ton) · Mini-split · 5°F 12,500 Btu/h · Cold output 89% · HSPF2 10.5 · 1 pairing

Sharp heat pumps, ranked by seasonal cooling efficiency (SEER2), then heating efficiency (HSPF2)
# Model Brands Type Size At 5°FBtu/h · heating At 47°FBtu/h · heating At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed SEER2median pairing HSPF2Btu/Wh · median pairing Compressor Refrigerant Market Pairings
1 AE-X18CHU Sharp Mini-split 18,000 Btu (1.5-ton)19,500 21,600 18,000 90% 2.20 25.0 11.5 Variable R-32 US CA 1
2 AE-X18ZHU Sharp Mini-split 18,000 Btu (1.5-ton)19,500 21,600 18,000 90% 2.20 25.0 11.5 Variable R-32 CA 1
3 AE-X12CHU Sharp Mini-split 12,000 Btu (1-ton)16,000 16,000 12,000 100% 2.10 25.0 11.0 Variable R-32 US CA 2
4 AE-X12ZHU1 Sharp Mini-split 12,000 Btu (1-ton)16,000 16,000 12,000 100% 2.10 25.0 11.0 Variable R-32 US CA 1
5 AY-XP12ZHU1: AE-X12ZHU1 Sharp Central 12,000 Btu (1-ton)16,000 16,000 12,000 100% 2.10 25.0 11.0 Variable R-32 US 1
6 AE-X3M24BU Sharp Mini-split 24,000 Btu (2-ton)21,200 26,000 24,000 82% 2.30 24.0 11.5 Variable R-32 US CA 1
7 AE-X3M24CUSame as AE-X3M24BU Sharp Mini-split 24,000 Btu (2-ton)21,200 26,000 24,000 82% 2.30 24.0 11.5 Variable R-32 US CA 1
8 AE-X18CU Sharp Mini-split 18,000 Btu (1.5-ton)19,000 21,600 18,000 88% 2.20 24.0 11.0 Variable R-32 US CA 2
9 AE-X18ZU1 Sharp Mini-split 18,000 Btu (1.5-ton)18,000 21,600 18,000 83% 2.20 24.0 11.0 Variable R-32 US CA 2
10 AE-X12DWU Sharp Mini-split 12,000 Btu (1-ton)15,500 16,000 12,000 97% 1.90 24.0 11.0 Variable R-32 US CA 1
11 AE-X15CU Sharp Mini-split 15,000 Btu15,300 18,000 15,000 85% 2.10 24.0 11.0 Variable R-32 US CA 2
12 AE-X15ZU1 Sharp Mini-split 15,000 Btu15,300 18,000 15,000 85% 2.10 24.0 11.0 Variable R-32 US CA 2
13 AE-X24CU Sharp Mini-split 24,000 Btu (2-ton)19,000 24,000 22,000 79% 2.20 22.0 11.0 Variable R-32 US CA 1
14 AE-X24ZU1 Sharp Mini-split 24,000 Btu (2-ton)19,000 24,000 22,000 79% 2.20 22.0 11.0 Variable R-32 US CA 1
15 AE-X12CU Sharp Mini-split 12,000 Btu (1-ton)12,700 14,000 12,000 91% 2.10 22.0 11.0 Variable R-32 US CA 1
16 AE-X12ZU1 Sharp Mini-split 12,000 Btu (1-ton)12,000 14,000 12,000 86% 2.10 22.0 11.0 Variable R-32 US CA 1
17 AE-X12CPU Sharp Mini-split 12,000 Btu (1-ton)12,500 14,000 12,500 89% 2.10 21.0 10.5 Variable R-32 US CA 1

The share is heat output at 5°F divided by the 47°F rating. Tests use different compressor speeds.

17 of 17 units

Other sizes

Every size class, with how many units it holds and its median heat output at 5°F