Heat Pump List

Tools

27VNA048A*030*

27VNA048A*030* is in the certified data.

Its certified full-speed heating output at 5°F is 33,000–37,600 Btu/h, 70–75% of its 47°F rating (tests at different compressor speeds), depending on the pairing.

Carrier · central heat pump

27VNA048A*030* is in the certified data as of Sep 19, 2026. 27VNA048A*030* changed its certified SEER2 on AHRI certificate 215662627 from 19.0 to 18.5 in the certified data between August 2025 and September 2026.

376 certified pairings with 141 different figures. See all

Certified heating and cooling

Heating at 47°F

50,000

45,500 at 17°F

36,400 at 5°F

Btu/h, certified

2.00 COP at 5°F

Cooling at 95°F

47,000

Btu/h, certified

EER2 10.0 at 95°F

SEER2 18.5

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for 27VNA048A*030*, by outdoor temperature Heating: 36,400 Btu/h at 5°F, 45,500 Btu/h at 17°F, 50,000 Btu/h at 47°F. Cooling: 47,000 Btu/h at 95°F. The bars start at zero. Median of 4-ton central models: 36,400 Btu/h at 5°F, 35,000 Btu/h at 17°F, 48,000 Btu/h at 47°F, 48,000 Btu/h at 95°F. 0 10,000 20,000 30,000 40,000 50,000 Btu/h 36,400 5°F 45,500 17°F 50,000 47°F 47,000 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 4-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 50,000 Btu/h of heat at 47°F, 45,500 Btu/h at 17°F, and 36,400 Btu/h at 5°F, 73% of its 47°F rating. It delivers 47,000 Btu/h of cooling at 95°F. At 5°F that is 100 Btu/h short of the example heating load of 36,500 Btu/h; at 95°F it is 29,000 Btu/h above the example cooling load of 18,000 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 1,500 sq ft where winters reach 5°F: heating runs from 36,500 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 18,000 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 215675363 · listed by Carrier · certified May 1, 2026 · 16 pairings share these values

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 4-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 36,40010.67 kW 0% 2.00
17°Ffull speed 45,50013.33 kW +30% NR
47°Fnormal speed 50,00014.65 kW +4% NR
95°Fcooling, full load 47,00013.77 kW — NR

EER2 10.0 in that test. SEER2 18.5 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
5.33kW
Electrical input in the 95°F cooling test
4.70kW
Seasonal average heating COP
2.64

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 48,000 Btu heat pumps

4-ton central models

This pairing at 5°F
36,400 Btu/h
This unit at 5°F median across its pairings
36,400 Btu/h
Median of 4-ton central models at 5°F
36,400 Btu/h
Models in this group
408

This unit is above 50% of them, at number 205 of 408 by heat at 5°F. The middle half of the group runs 25,350 to 46,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Closest models by heat at 5°F

Every 48,000 Btu (4-ton) unit, ranked by cooling efficiency, then heating efficiency

Certified values for 27VNA048A*030*

376 pairings · 376 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for 27VNA048A*030*
This pairingAll pairings
Heating
Heat output at 47°F normal speed 50,000 Btu/h 47,000–50,000 Btu/h
Heat output at 17°F full speed 45,500 Btu/h 41,000–47,500 Btu/h
Heat output at 5°F full speed 36,400 Btu/h 33,000–37,600 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 73%
COP at 5°F full speed 2.00 1.92–2.20
HSPF2 Region IV 9.0 8.5–9.5
Cooling
Cooling capacity at 95°F full-load test 47,000 Btu/h 43,500–49,000 Btu/h
EER2 at 95°F 10.0 9.0–10.5
SEER2 cooling season 18.5 15.5–19.5
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Variable speed
Indoor unit CVAMA4821XMA*+UI 20 indoor units
Furnace58CU*A080C21**20 30 furnaces
Cold-climate designation EPA's designation, as published Yes On every pairing
ENERGY STAR Most Efficient EPA's designation, as published Yes On some pairings
Where it is sold US and Canada US and Canada
Model string as certified 27VNA048A*030*

Pairings, by indoor-unit class

20 indoor units · 376 certified pairings

One row per indoor unit certified with this outdoor unit.

Furnace paired · 10 indoor units

  1. CSAH*6012AM*+UI brand not stated 33,800 Btu/hat 5°F, full speed

    29 pairings, 29 with a furnace · 47°F 48,000 Btu/h · 95°F cooling 45,500 Btu/h · Cold output 70% · COP 2.06

  2. CVAMA6021XMA*+UI brand not stated 36,800 Btu/hat 5°F, full speed

    26 pairings, 26 with a furnace · 47°F 50,000 Btu/h · 95°F cooling 48,000 Btu/h · Cold output 74% · COP 2.00

  3. CVAVA6021XMA*+UI brand not stated 36,800 Btu/hat 5°F, full speed

    26 pairings, 26 with a furnace · 47°F 50,000 Btu/h · 95°F cooling 48,000 Btu/h · Cold output 74% · COP 2.00

  4. CVAMA4921XMA*+UI brand not stated 36,800 Btu/hat 5°F, full speed

    25 pairings, 25 with a furnace · 47°F 50,000 Btu/h · 95°F cooling 48,000 Btu/h · Cold output 74% · COP 2.00

  5. CAA**4821AM*+UI brand not stated 34,200 Btu/hat 5°F, full speed

    24 pairings, 24 with a furnace · 47°F 48,500 Btu/h · 95°F cooling 44,000 Btu/h · Cold output 71% · COP 2.04

  6. CAA**6121AM*+UI brand not stated 33,800 Btu/hat 5°F, full speed

    24 pairings, 24 with a furnace · 47°F 48,000 Btu/h · 95°F cooling 46,000 Btu/h · Cold output 71% · COP 2.07

  7. CVAVA6121XMA*+UI brand not stated 36,800 Btu/hat 5°F, full speed

    24 pairings, 24 with a furnace · 47°F 50,000 Btu/h · 95°F cooling 48,500 Btu/h · Cold output 74% · COP 2.00

  8. CAA**6024AM*+UI brand not stated 33,600 Btu/hat 5°F, full speed

    20 pairings, 20 with a furnace · 47°F 47,500 Btu/h · 95°F cooling 45,000 Btu/h · Cold output 71% · COP 2.06

  9. CAA**6124AM*+UI brand not stated 33,600 Btu/hat 5°F, full speed

    20 pairings, 20 with a furnace · 47°F 47,500 Btu/h · 95°F cooling 46,000 Btu/h · Cold output 71% · COP 2.08

  10. CVAMA4821XMA*+UI (the pairing on screen) brand not stated 36,400 Btu/hat 5°F, full speed

    20 pairings, 20 with a furnace · 47°F 50,000 Btu/h · 95°F cooling 47,000 Btu/h · Cold output 73% · COP 2.00

Indoor units in the furnace paired class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
CSAH*6012AM*+UI — 33,800 48,000 45,500 70% 2.06 Yes 29
CVAMA6021XMA*+UI — 36,800 50,000 48,000 74% 2.00 Yes 26
CVAVA6021XMA*+UI — 36,800 50,000 48,000 74% 2.00 Yes 26
CVAMA4921XMA*+UI — 36,800 50,000 48,000 74% 2.00 Yes 25
CAA**4821AM*+UI — 34,200 48,500 44,000 71% 2.04 Yes 24
CAA**6121AM*+UI — 33,800 48,000 46,000 71% 2.07 Yes 24
CVAVA6121XMA*+UI — 36,800 50,000 48,500 74% 2.00 Yes 24
CAA**6024AM*+UI — 33,600 47,500 45,000 71% 2.06 Yes 20
CAA**6124AM*+UI — 33,600 47,500 46,000 71% 2.08 Yes 20
CVAMA4821XMA*+UI (the pairing on screen) — 36,400 50,000 47,000 73% 2.00 Yes 20

The share is heat output at 5°F divided by the 47°F rating.

Showing 10 of 20 indoor units All 376 certified pairings

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

Variants of the same model number

7 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.

6 of 7 shown.

Other model numbers with identical certified values

4 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.

3 of 4 shown.

Product history

  • 27VNA048A*030* changed its certified SEER2 on AHRI certificate 215662627 from 19.0 to 18.5 in the certified data between August 2025 and September 2026.
  • 27VNA048A*030* changed its certified HSPF2 on AHRI certificate 215662627 from 9.0 to 9.5 in the certified data between August 2025 and September 2026.
  • 27VNA048A*030* changed its certified COP at 5°F on AHRI certificate 215662627 from 2.10 to 2.14 in the certified data between August 2025 and September 2026.
  • 27VNA048A*030* first appeared in the certified data between February 2025 and March 2025.

History and definitions

History

First certified record
Most recent certified record
Measurements reported
May 1, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “27VNA048A*030* — certified heat output”. Certified figures dated , checked daily.