37MBRAQ48AA3
37MBRAQ48AA3 is in the certified data.
Its certified full-speed heating output at 5°F is 35,200–40,500 Btu/h10.32–11.87 kW, 70–81% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
Bryant, Carrier + 3 more · mini-split heat pump
37MBRAQ48AA3 is in the certified data as of Sep 19, 2026.
- 48,000 Btu (4-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
50,00014.65NR
No 47°F rating for this pairing.
39,00011.43NR at 17°F
38,00011.14NR at 5°F
Btu/hkW, certified
2.00NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 50,000 Btu/h14.65 kW of heat at 47°F, 39,000 Btu/h11.43 kW at 17°F, and 38,000 Btu/h11.14 kW at 5°F, 76% of its 47°F rating. It delivers 48,000 Btu/h14.07 kW of cooling at 95°F. At 5°F that is 4,000 Btu/h1.17 kW short of the example heating load of 42,000 Btu/h12.31 kW; at 95°F it is 27,000 Btu/h7.91 kW above the example cooling load of 21,000 Btu/h6.15 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,750 sq ft where winters reach 5°F: heating runs from 42,000 Btu/h12.31 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 21,000 Btu/h6.15 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 215323855 · listed by Carrier · certified Mar 4, 2025 · 5 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 38,00011.14 kW | −10% | 2.00 | |
| 17°Ffull speed | 39,00011.43 kW | +3% | NR | |
| 47°Fnormal speed | 50,00014.65 kW | +2% | NR | |
| 95°Fcooling, full load | 48,00014.07 kW | — | NR |
EER2 10.0 in that test. SEER2 17.2 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 5.57kW
- Electrical input in the 95°F cooling test
- 4.80kW
- Seasonal average heating COP
- 2.87
These exclude backup resistance heat.
How it compares with other 48,000 Btu heat pumps
4-ton mini-split models
- This pairing at 5°F
- 38,000 Btu/h11.14 kWNR
- This unit at 5°F median across its pairings
- 38,000 Btu/h11.14 kW
- Median of 4-ton mini-split models at 5°F
- 42,000 Btu/h12.31 kW
- Models in this group
- 321
This unit is above 35% of them, at number 208 of 321 by heat at 5°F. The middle half of the group runs 37,000 to 47,500 Btu/h.
Closest models by heat at 5°F
- AOUH48KUAS1Fujitsu · 38,500 Btu/h
- MCY-MAP0487HS-ULToshiba Carrier · 38,500 Btu/h
- YN048GMSI20RUGPioneer · 38,500 Btu/h
- ALC24-48H1BApooDr and AproDr · 38,000 Btu/h
- AM048FCMDCGSamsung · 38,000 Btu/h
- CH-R48LCU-230VOCooper&Hunter · 38,000 Btu/h
Every 48,000 Btu (4-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for 37MBRAQ48AA3
20 pairings · 20 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 50,000 Btu/h14.65 kWNR | 50,000 Btu/h14.65 kW |
| Heat output at 17°F full speed | 39,000 Btu/h11.43 kWNR | 36,600–40,000 Btu/h10.73–11.72 kW |
| Heat output at 5°F full speed | 38,000 Btu/h11.14 kWNR | 35,200–40,500 Btu/h10.32–11.87 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 76%NR | |
| COP at 5°F full speed | 2.00NR | 1.90–2.11 |
| HSPF2 Region IV | 9.8NR | 9.8–10.2 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 48,000 Btu/h14.07 kWNR | 48,000 Btu/h14.07 kW |
| EER2 at 95°F | 10.0NR | 9.5–10.0 |
| SEER2 cooling season | 17.2NR | 17.2–19.9 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Variable speed | |
| Indoor unit | 45MBDAQ48XH3 | 4 indoor units |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On some pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | 37MBRAQ48AA3 | |
Pairings, by indoor-unit class
4 indoor units · 20 certified pairings
One row per indoor unit certified with this outdoor unit.
Air handler · 1 indoor unit
-
45MBAAQ48XA3 (the pairing on screen) brand not stated 35,200 Btu/h10.32 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| 45MBAAQ48XA3 (the pairing on screen) | — | 35,20010.32 | 50,00014.65 | 48,00014.07 | 70% | 1.90 | Yes | 5 |
Ductless indoor · 3 indoor units
-
45MBCAQ48XA3 (the pairing on screen) BRYANT 40,500 Btu/h11.87 kWat 5°F, full speed
-
45MBDAQ48XH3 (the pairing on screen) BRYANT 38,000 Btu/h11.14 kWat 5°F, full speed
-
45MCFAQ48XA3 (the pairing on screen) BRYANT 38,500 Btu/h11.28 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| 45MBCAQ48XA3 (the pairing on screen) | BRYANT | 40,50011.87 | 50,00014.65 | 48,00014.07 | 81% | 2.11 | Yes | 5 |
| 45MBDAQ48XH3 (the pairing on screen) | BRYANT | 38,00011.14 | 50,00014.65 | 48,00014.07 | 76% | 2.00 | Yes | 5 |
| 45MCFAQ48XA3 (the pairing on screen) | BRYANT | 38,50011.28 | 50,00014.65 | 48,00014.07 | 77% | 1.95 | Yes | 5 |
Sold as, and units with identical certified values
Brands listing this model number
Other brands that list these model numbers
- Are Bryant and Carrier heat pumps the same?127 shared model numbers
- Are Bryant and Midea heat pumps the same?108 shared model numbers
- Are Bryant and WeatherMaker heat pumps the same?108 shared model numbers
- Are Bryant and Payne heat pumps the same?107 shared model numbers
Model number as listed
- 37MBRAQ48AA3 20 pairings
Variants of the same model number
2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Mar 4, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read