5MXTH40AVJU
Daikin · mini-split heat pump
All 89 certified Daikin models
5MXTH40AVJU is in the certified data as of Sep 19, 2026.
- 42,000 Btu (3.5-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
40,50011.87NR
No 47°F rating for this pairing.
23,6006.92NR at 17°F
34,20010.02NR at 5°F
Btu/hkW, certified
1.85NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 40,500 Btu/h11.87 kW of heat at 47°F, 23,600 Btu/h6.92 kW at 17°F, and 34,200 Btu/h10.02 kW at 5°F, 84% of its 47°F rating. It delivers 41,500 Btu/h12.16 kW of cooling at 95°F. At 5°F that is 1,800 Btu/h0.53 kW short of the example heating load of 36,000 Btu/h10.55 kW; at 95°F it is 23,500 Btu/h6.89 kW above the example cooling load of 18,000 Btu/h5.28 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,500 sq ft where winters reach 5°F: heating runs from 36,000 Btu/h10.55 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 18,000 Btu/h5.28 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 218043346 · listed by Daikin · certified Jan 14, 2026 · 1 pairing carries these values
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 34,20010.02 kW | −5% | 1.85 | |
| 17°Ffull speed | 23,6006.92 kW | −26% | NR | |
| 47°Fnormal speed | 40,50011.87 kW | −8% | NR | |
| 95°Fcooling, full load | 41,50012.16 kW | — | NR |
EER2 10.1 in that test. SEER2 17.95 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 5.42kW
- Electrical input in the 95°F cooling test
- 4.11kW
- Seasonal average heating COP
- 2.60
These exclude backup resistance heat.
How it compares with other 42,000 Btu heat pumps
3.5-ton mini-split models
- This pairing at 5°F
- 34,200 Btu/h10.02 kWNR
- This unit at 5°F median across its pairings
- 34,200 Btu/h10.02 kW
- Median of 3.5-ton mini-split models at 5°F
- 36,000 Btu/h10.55 kW
- Models in this group
- 161
This unit is above 30% of them, at number 113 of 161 by heat at 5°F. The middle half of the group runs 33,000 to 37,000 Btu/h.
Among 42,000 Btu mini-split models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 57th of 161 (tied); HSPF2, 144th of 161 (tied). Models without that figure are left out.
Similar ratings at 47°F
These mini-split models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.
- RAV-BP421AT2P-UL: 42,000 Btu/h at 47°F (this model: 40,500); HSPF2 11.2 (this model: 8.86).
- AM5-H42/2DR3B: 42,000 Btu/h at 47°F (this model: 40,500); HSPF2 10.5 (this model: 8.86).
- ACIQ-42Z-E-HH-M5: 42,000 Btu/h at 47°F (this model: 40,500); HSPF2 10.25 (this model: 8.86).
Closest models by heat at 5°F
- FPHMR42A3DFriedrich, Rheem + 1 more · 35,000 Btu/h
- UMC48CN23STG1Coleman, Guardian + 1 more · 35,000 Btu/h
- ACIQ-42Z-E-HH-M5ACiQ · 34,400 Btu/h
- AM5-H42/2DR3BAUX · 34,000 Btu/h
- PAS-48BUFASDQ1-LACHitachi · 34,000 Btu/h
- RAV-BP421AT2P-ULToshiba Carrier · 33,400 Btu/h
Every 42,000 Btu (3.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Floor area at the cold test point
The median certified output of 34,200 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.
| Climate band | House condition | Btu/h per sq ft | Approximate sq ft |
|---|---|---|---|
| Mild | Drafty, little insulation | 24–42 | 810–1,430 |
| Mild | Typical | 16–26 | 1,320–2,140 |
| Mild | Tight, well insulated | 10–18 | 1,900–3,420 |
| Cold | Drafty, little insulation | 28–52 | 660–1,220 |
| Cold | Typical | 18–30 | 1,140–1,900 |
| Cold | Tight, well insulated | 12–22 | 1,550–2,850 |
| Very cold | Drafty, little insulation | 32–58 | 590–1,070 |
| Very cold | Typical | 22–38 | 900–1,550 |
| Very cold | Tight, well insulated | 16–28 | 1,220–2,140 |
This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.
Certified values for 5MXTH40AVJU
3 pairings · 3 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 40,500 Btu/h11.87 kWNR | 40,000–41,000 Btu/h11.72–12.02 kW |
| Heat output at 17°F full speed | 23,600 Btu/h6.92 kWNR | 23,200–23,800 Btu/h6.80–6.98 kW |
| Heat output at 5°F full speed | 34,200 Btu/h10.02 kWNR | 30,400–38,000 Btu/h8.91–11.14 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 84%NR | |
| COP at 5°F full speed | 1.85NR | 1.80–1.90 |
| HSPF2 Region IV | 8.9NR | 8.2–9.5 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 41,500 Btu/h12.16 kWNR | 40,000–43,000 Btu/h11.72–12.60 kW |
| EER2 at 95°F | 10.1NR | 8.5–11.7 |
| SEER2 cooling season | 17.95NR | 15.9–20.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-32 | |
| Compressor | Variable speed | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On some pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | 5MXTH40AVJU* | |
Pairings, by indoor-unit class
3 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor
-
None listed (the pairing on screen) DAIKIN 34,200 Btu/h10.02 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | DAIKIN | 34,20010.02 | 40,50011.87 | 41,50012.16 | 84% | 1.85 | Yes | 3 |
Sold as, and units with identical certified values
Variants of the same model number
2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
Other model numbers with identical certified values
2 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
Other AURORA Multi models by nominal cooling size: 2MXT18AVJU8 (18,000 Btu), 3MXT24AVJU (24,000 Btu), 3MXTH24AVJU (24,000 Btu), 4MXT36AVJU (36,000 Btu), 5MXT40AVJU (42,000 Btu).
History
- First certified record
- Most recent certified record
- Measurements reported
- Jan 14, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read