5TWX7048A1
5TWX7048A1 is in the certified data.
Its certified full-speed heating output at 5°F is 31,800–33,200 Btu/h9.32–9.73 kW, 72–74% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
Trane · central heat pump
5TWX7048A1 is in the certified data as of Sep 19, 2026. 5TWX7048A1 changed its certified COP at 5°F on 12 pairings in the certified data between August 2025 and September 2026. The new figure is lower on all 12.
- 42,000 Btu (3.5-ton)
- Central
- Two-stage
- US and Canada
Certified heating and cooling
Heating at 47°F
44,00012.90NR
No 47°F rating for this pairing.
29,2008.56NR at 17°F
32,2009.44NR at 5°F
Btu/hkW, certified
2.20NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 44,000 Btu/h12.90 kW of heat at 47°F, 29,200 Btu/h8.56 kW at 17°F, and 32,200 Btu/h9.44 kW at 5°F, 73% of its 47°F rating. It delivers 43,500 Btu/h12.75 kW of cooling at 95°F. At 5°F that is 800 Btu/h0.23 kW short of the example heating load of 33,000 Btu/h9.67 kW; at 95°F it is 26,500 Btu/h7.77 kW above the example cooling load of 17,000 Btu/h4.98 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at high stage; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,400 sq ft where winters reach 5°F: heating runs from 33,000 Btu/h9.67 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 17,000 Btu/h4.98 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 216764425 · listed by Trane · certified Apr 9, 2025 · 8 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 32,2009.44 kW | −2% | 2.20 | |
| 17°Ffull speed | 29,2008.56 kW | −6% | NR | |
| 47°Fhigh stage | 44,00012.90 kW | 0% | NR | |
| 95°Fcooling, full load | 43,50012.75 kW | — | NR |
EER2 12.0 in that test. SEER2 16.5 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 4.29kW
- Electrical input in the 95°F cooling test
- 3.63kW
- Seasonal average heating COP
- 2.64
These exclude backup resistance heat.
How it compares with other 42,000 Btu heat pumps
3.5-ton central models
- This pairing at 5°F
- 32,200 Btu/h9.44 kWNR
- This unit at 5°F median across its pairings
- 32,200 Btu/h9.44 kW
- Median of 3.5-ton central models at 5°F
- 33,000 Btu/h9.67 kW
- Models in this group
- 222
This unit is above 48% of them, at number 115 of 222 by heat at 5°F. The middle half of the group runs 20,000 to 40,000 Btu/h.
Closest models by heat at 5°F
- MOVC-60HDN10-M16GMidea · 33,000 Btu/h
- WFPU18Z483CFriedrich · 33,000 Btu/h
- 5TWR7048A1Trane · 32,200 Btu/h
- DZ6VSA481EADaikin · 31,000 Btu/h
- GZV7SA4210AGoodman · 31,000 Btu/h
- DZ6VSA421EADaikin · 30,600 Btu/h
Every 42,000 Btu (3.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for 5TWX7048A1
220 pairings · 220 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F high stage | 44,000 Btu/h12.90 kWNR | 43,500–45,500 Btu/h12.75–13.33 kW |
| Heat output at 17°F full speed | 29,200 Btu/h8.56 kWNR | 28,800–39,500 Btu/h8.44–11.58 kW |
| Heat output at 5°F full speed | 32,200 Btu/h9.44 kWNR | 31,800–33,200 Btu/h9.32–9.73 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 73%NR | |
| COP at 5°F full speed | 2.20NR | 2.10–2.23 |
| HSPF2 Region IV | 9.0NR | 8.5–9.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 43,500 Btu/h12.75 kWNR | 43,000–44,500 Btu/h12.60–13.04 kW |
| EER2 at 95°F | 12.0NR | 11.2–12.7 |
| SEER2 cooling season | 16.5NR | 15.2–17.1 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Two-stage | |
| Indoor unit | 5PX*C009AS3 | 32 indoor units |
| Furnace | S8X1C080M5PSC | 43 furnaces |
| Cold-climate designation EPA's designation, as published | NC | On some pairings |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On some pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | 5TWX7048A1 | |
Pairings, by indoor-unit class
32 indoor units · 220 certified pairings
One row per indoor unit certified with this outdoor unit.
Furnace paired · 6 indoor units
-
5TXCD010AS3 (the pairing on screen) brand not stated 32,200 Btu/h9.44 kWat 5°F, full speed
-
5PX*D008AS3 (the pairing on screen) brand not stated 32,800 Btu/h9.61 kWat 5°F, full speed
-
5TXCD008AS3 (the pairing on screen) brand not stated 32,800 Btu/h9.61 kWat 5°F, full speed
-
5PX*CD09AS3 (the pairing on screen) brand not stated 32,200 Btu/h9.44 kWat 5°F, full speed
-
5PX*DD10AS3 (the pairing on screen) brand not stated 32,600 Btu/h9.55 kWat 5°F, full speed
-
5TXCC007AS3 (the pairing on screen) brand not stated 32,800 Btu/h9.61 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · high stage | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| 5TXCD010AS3 (the pairing on screen) | — | 32,2009.44 | 44,00012.90 | 43,50012.75 | 73% | 2.20 | Yes | 33 |
| 5PX*D008AS3 (the pairing on screen) | — | 32,8009.61 | 44,50013.04 | 43,50012.75 | 73% | 2.20 | Yes | 25 |
| 5TXCD008AS3 (the pairing on screen) | — | 32,8009.61 | 44,50013.04 | 43,50012.75 | 73% | 2.20 | Yes | 25 |
| 5PX*CD09AS3 (the pairing on screen) | — | 32,2009.44 | 44,00012.90 | 43,50012.75 | 73% | 2.10 | Yes | 18 |
| 5PX*DD10AS3 (the pairing on screen) | — | 32,6009.55 | 44,50013.04 | 43,00012.60 | 73% | 2.10 | NC | 16 |
| 5TXCC007AS3 (the pairing on screen) | — | 32,8009.61 | 45,00013.19 | 43,00012.60 | 73% | 2.10 | Yes | 2 |
Air handler · 4 indoor units
-
5PX*D010AS3 (the pairing on screen) brand not stated 32,200 Btu/h9.44 kWat 5°F, full speed
-
5PX*C009AS3 (the pairing on screen) brand not stated 32,200 Btu/h9.44 kWat 5°F, full speed
-
5TXCC009AS3 (the pairing on screen) brand not stated 32,200 Btu/h9.44 kWat 5°F, full speed
-
5PX*C007AS3+P0V0C000M50SD (the pairing on screen) brand not stated 32,400 Btu/h9.50 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · high stage | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| 5PX*D010AS3 (the pairing on screen) | — | 32,2009.44 | 44,00012.90 | 43,50012.75 | 73% | 2.20 | Yes | 34 |
| 5PX*C009AS3 (the pairing on screen) | — | 32,2009.44 | 44,00012.90 | 43,50012.75 | 73% | 2.10 | Yes | 22 |
| 5TXCC009AS3 (the pairing on screen) | — | 32,2009.44 | 44,00012.90 | 43,50012.75 | 73% | 2.10 | Yes | 22 |
| 5PX*C007AS3+P0V0C000M50SD (the pairing on screen) | — | 32,4009.50 | 44,50013.04 | 43,00012.60 | 73% | 2.20 | NC | 1 |
Sold as, and units with identical certified values
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- 5TWX7048A1 changed its certified COP at 5°F on 12 pairings in the certified data between August 2025 and September 2026. The new figure is lower on all 12.
- 5TWX7048A1 first appeared in the certified data between February 2025 and March 2025.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Apr 9, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read