A5HP5048A1
A5HP5048A1 is in the certified data.
Its certified full-speed heating output at 5°F is 21,400–22,600 Btu/h6.27–6.62 kW, 50–52% of its 47°F rating, depending on the pairing.
Ameristar and RunTru · central heat pump
A5HP5048A1 is in the certified data as of Sep 19, 2026.
- 42,000 Btu (3.5-ton)
- Central
- Single stage
- US and Canada
Certified heating and cooling
Heating at 47°F
43,00012.60NR
No 47°F rating for this pairing.
28,6008.38NR at 17°F
22,2006.51NR at 5°F
Btu/hkW, certified
2.10NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 43,000 Btu/h12.60 kW of heat at 47°F, 28,600 Btu/h8.38 kW at 17°F, and 22,200 Btu/h6.51 kW at 5°F, 52% of its 47°F rating. It delivers 44,500 Btu/h13.04 kW of cooling at 95°F. At 5°F that is 10,800 Btu/h3.17 kW short of the example heating load of 33,000 Btu/h9.67 kW; at 95°F it is 27,500 Btu/h8.06 kW above the example cooling load of 17,000 Btu/h4.98 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at one speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,400 sq ft where winters reach 5°F: heating runs from 33,000 Btu/h9.67 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 17,000 Btu/h4.98 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 215575582 · listed by RunTru · certified Apr 9, 2025 · 8 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Fone compressor speed | 22,2006.51 kW | −33% | 2.10 | |
| 17°Fone compressor speed | 28,6008.38 kW | −8% | NR | |
| 47°Fone compressor speed | 43,00012.60 kW | −2% | NR | |
| 95°Fcooling, full load | 44,50013.04 kW | — | NR |
EER2 12.0 in that test. SEER2 15.2 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 3.10kW
- Electrical input in the 95°F cooling test
- 3.71kW
- Seasonal average heating COP
- 2.29
These exclude backup resistance heat.
How it compares with other 42,000 Btu heat pumps
3.5-ton central models
- This pairing at 5°F
- 22,200 Btu/h6.51 kWNR
- This unit at 5°F median across its pairings
- 22,200 Btu/h6.51 kW
- Median of 3.5-ton central models at 5°F
- 33,000 Btu/h9.67 kW
- Models in this group
- 222
This unit is above 43% of them, at number 127 of 222 by heat at 5°F. The middle half of the group runs 20,000 to 40,000 Btu/h.
Closest models by heat at 5°F
- GZV7SA4210AGoodman · 31,000 Btu/h
- DZ6VSA421EADaikin · 30,600 Btu/h
- GSZV904810AGoodman · 25,400 Btu/h
- N5HP5048A1American Standard and Trane · 22,200 Btu/h
- 5TWR5048A1Trane · 22,000 Btu/h
- 5TWR6048A1Trane · 22,000 Btu/h
Every 42,000 Btu (3.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for A5HP5048A1
156 pairings · 156 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F one speed | 43,000 Btu/h12.60 kWNR | 41,500–44,500 Btu/h12.16–13.04 kW |
| Heat output at 17°F full speed | 28,600 Btu/h8.38 kWNR | 27,600–29,400 Btu/h8.09–8.62 kW |
| Heat output at 5°F full speed | 22,200 Btu/h6.51 kWNR | 21,400–22,600 Btu/h6.27–6.62 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 52%NR | |
| COP at 5°F full speed | 2.10NR | 2.00–2.30 |
| HSPF2 Region IV | 7.8NR | 7.8–8.1 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 44,500 Btu/h13.04 kWNR | 43,000–45,500 Btu/h12.60–13.33 kW |
| EER2 at 95°F | 12.0NR | 11.7–12.0 |
| SEER2 cooling season | 15.2NR | 15.2–16.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Single stage | |
| Indoor unit | 5PX*C009AS3+TSTAT | 22 indoor units |
| Furnace | A801X100CM5SD | 21 furnaces |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On some pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | A5HP5048A1 | |
Pairings, by indoor-unit class
22 indoor units · 156 certified pairings
One row per indoor unit certified with this outdoor unit.
Furnace paired · 9 indoor units
-
5TXCD010AS3+TSTAT (the pairing on screen) brand not stated 21,800 Btu/h6.39 kWat 5°F, full speed
-
5PX*D010AS3+TSTAT (the pairing on screen) brand not stated 21,800 Btu/h6.39 kWat 5°F, full speed
-
5TXCC007AS3+TSTAT (the pairing on screen) brand not stated 22,400 Btu/h6.56 kWat 5°F, full speed
-
5PX*C009AS3+TSTAT (the pairing on screen) brand not stated 22,000 Btu/h6.45 kWat 5°F, full speed
-
5TXCC009AS3+TSTAT (the pairing on screen) brand not stated 22,000 Btu/h6.45 kWat 5°F, full speed
-
5TXCB006AS3+TSTAT (the pairing on screen) brand not stated 22,600 Btu/h6.62 kWat 5°F, full speed
-
5PX*C007AS3+TSTAT (the pairing on screen) brand not stated 22,600 Btu/h6.62 kWat 5°F, full speed
-
5PX*DD10AS3+TSTAT (the pairing on screen) brand not stated 22,200 Btu/h6.51 kWat 5°F, full speed
-
5PX*D008AS3+TSTAT (the pairing on screen) brand not stated 22,200 Btu/h6.51 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · one speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| 5TXCD010AS3+TSTAT (the pairing on screen) | — | 21,8006.39 | 42,00012.31 | 43,50012.75 | 51% | 2.10 | NC | 30 |
| 5PX*D010AS3+TSTAT (the pairing on screen) | — | 21,8006.39 | 42,00012.31 | 44,00012.90 | 52% | 2.10 | NC | 22 |
| 5TXCC007AS3+TSTAT (the pairing on screen) | — | 22,4006.56 | 44,00012.90 | 44,00012.90 | 51% | 2.10 | NC | 20 |
| 5PX*C009AS3+TSTAT (the pairing on screen) | — | 22,0006.45 | 43,00012.60 | 44,50013.04 | 52% | 2.10 | NC | 18 |
| 5TXCC009AS3+TSTAT (the pairing on screen) | — | 22,0006.45 | 43,00012.60 | 44,50013.04 | 52% | 2.10 | NC | 18 |
| 5TXCB006AS3+TSTAT (the pairing on screen) | — | 22,6006.62 | 43,75012.82 | 43,50012.75 | 51% | 2.00 | NC | 8 |
| 5PX*C007AS3+TSTAT (the pairing on screen) | — | 22,6006.62 | 44,00012.90 | 44,50013.04 | 51% | 2.10 | NC | 6 |
| 5PX*DD10AS3+TSTAT (the pairing on screen) | — | 22,2006.51 | 43,00012.60 | 44,00012.90 | 52% | 2.10 | NC | 6 |
| 5PX*D008AS3+TSTAT (the pairing on screen) | — | 22,2006.51 | 43,50012.75 | 44,00012.90 | 51% | 2.10 | NC | 2 |
Air handler · 1 indoor unit
-
5PX*C009AS3+TSTAT+P0V0C000M50SD (the pairing on screen) brand not stated 22,200 Btu/h6.51 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · one speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| 5PX*C009AS3+TSTAT+P0V0C000M50SD (the pairing on screen) | — | 22,2006.51 | 43,00012.60 | 45,50013.33 | 52% | 2.20 | NC | 2 |
Sold as, and units with identical certified values
Brands listing this model number
Other brands that list these model numbers
Model number as listed
- A5HP5048A1 156 pairings
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Apr 9, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read