ACK09N3H1
ACK09N3H1 is in the certified data.
Its certified full-speed heating output at 5°F is 5,900 Btu/h1.73 kW, 72% of its 47°F rating (tests at different compressor speeds) across its certified pairings.
Ephoca and Innova · central heat pump
All 190 certified Ephoca models · All 189 certified Innova models
ACK09N3H1 is in the certified data as of Sep 19, 2026.
Certified heating and cooling
Heating at 47°F
8,2002.40NR
No 47°F rating for this pairing.
7,8002.29NR at 17°F
5,9001.73NR at 5°F
Btu/hkW, certified
1.75NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 8,200 Btu/h2.40 kW of heat at 47°F, 7,800 Btu/h2.29 kW at 17°F, and 5,900 Btu/h1.73 kW at 5°F, 72% of its 47°F rating. It delivers 6,100 Btu/h1.79 kW of cooling at 95°F. At 5°F that is 100 Btu/h0.03 kW short of the example heating load of 6,000 Btu/h1.76 kW; at 95°F it is 3,100 Btu/h0.91 kW above the example cooling load of 3,000 Btu/h0.88 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 6,000 Btu central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 250 sq ft where winters reach 5°F: heating runs from 6,000 Btu/h1.76 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 3,000 Btu/h0.88 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 218330553 · listed by Innova · certified Mar 26, 2026 · 2 pairings on 2 certificates share these values
Rebates where you live
Meets the recorded equipment thresholds of 51 programs in 31 states, provinces, or territories:Alabama (1), Arizona (1), California (3), Colorado (1), Connecticut (3), Idaho (2), Illinois (1), Kansas (1), Kentucky (1), Maryland (3), Massachusetts (3), Michigan (2), Minnesota (3), Mississippi (2), Nevada (1), New Hampshire (3), New Jersey (2), New York (4), North Carolina (1), Oregon (2), Pennsylvania (1), Rhode Island (3), South Carolina (1), Tennessee (1), Texas (2), Utah (1), Vermont (3), Washington (3), Wisconsin (1), British Columbia (3), Newfoundland and Labrador (1).
All 51 programs by state and province
Alabama
Arizona
California
- California Home Electrification and Appliance Rebates
- LADWP Consumer Rebate Program
- SMUD Heating and Cooling Rebate
Colorado
Connecticut
- Energize CT Residential Air Source Heat Pump Rebate · Eversource · United Illuminating
- Energize CT Residential Energy Optimization Heat Pump Rebate · Eversource · United Illuminating
- New England Heat Pump Accelerator
Idaho
Illinois
Kansas
Kentucky
Maryland
- BGE Smart Energy Savers Heating and Cooling
- Delmarva Power Maryland HVAC Efficiency Program
- Pepco Maryland HVAC Efficiency Program
Massachusetts
- Mass Save Air Source Heat Pump Rebates · Cape Light Compact · Eversource · National Grid · Unitil · Berkshire Gas · Liberty
- Mass Save Enhanced Heat Pump Rebates · Cape Light Compact · Eversource · National Grid · Unitil · Berkshire Gas · Liberty
- New England Heat Pump Accelerator
Michigan
Minnesota
- Save Energy Minnesota
- Wright-Hennepin Air Source Heat Pump Rebate · Wright-Hennepin Cooperative Electric Association
- Xcel Energy Minnesota Air Source Heat Pump Rebates
Mississippi
- EnergyRight Home Energy Rebates · TVA EnergyRight · EPB
- Entergy Mississippi Residential Heating and Cooling
Nevada
New Hampshire
- NHEC Heat Pump Incentives · New Hampshire Electric Cooperative
- NHSaves Air-Source Heat Pump Rebates · Eversource · Liberty · Unitil
- New England Heat Pump Accelerator
New Jersey
New York
- EmPower+
- NYS Clean Heat: Central Hudson, NYSEG, RG&E, and O&R · Orange & Rockland
- NYS Clean Heat: Con Edison
- NYS Clean Heat: National Grid
North Carolina
Oregon
- Energy Trust of Oregon Heat Pump Incentives · Portland General Electric (PGE) · Pacific Power
- Idaho Power Heating and Cooling Efficiency Program
Pennsylvania
Rhode Island
- Clean Heat Rhode Island Low to Moderate Income Incentive · Rhode Island Energy · Clear River Electric & Water District · Block Island Power Company
- New England Heat Pump Accelerator
- Rhode Island Energy Heat Pump Rebates
South Carolina
Tennessee
Texas
- Austin Energy Air Conditioning and Heat Pump Rebate
- CenterPoint Residential Standard Offer Program · CenterPoint Energy
Utah
Vermont
- Burlington Electric Heat Pump Rebates · Burlington Electric Department
- Efficiency Vermont Heat Pump Discounts
- Green Mountain Power Income-Eligible Heat Pump Rebate
Washington
- Avista Heat Pump Rebates
- PSE Gas-to-Heat-Pump Conversion Rebate · Puget Sound Energy
- Seattle City Light Heat Pump Rebates
Wisconsin
British Columbia
- Home Renovation Rebate: Heat Pump Replacing Electric Heat · BC Hydro · FortisBC · Grand Forks · Penticton · Summerland · Nelson Hydro
- Home Renovation Rebate: Northern Dual Fuel Heat Pump · BC Hydro · Pacific Northern Gas
- Home Renovation Rebate: Northern Fuel Switch · BC Hydro · Pacific Northern Gas · FortisBC (gas)
Newfoundland and Labrador
Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.
A utility program is for that utility's customers.
Choose location
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 5,9001.73 kW | 0% | 1.75 | |
| 17°Ffull speed | 7,8002.29 kW | 0% | NR | |
| 47°Fnormal speed | 8,2002.40 kW | 0% | NR | |
| 95°Fcooling, full load | 6,1001.79 kW | — | NR |
EER2 11.56 in that test. SEER2 15.3 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 0.99kW
- Electrical input in the 95°F cooling test
- 0.53kW
- Seasonal average heating COP
- 2.70
These exclude backup resistance heat.
How it compares with other 6,000 Btu heat pumps
6,000 Btu central models
- This pairing at 5°F
- 5,900 Btu/h1.73 kWNR
- This unit at 5°F median across its pairings
- 5,900 Btu/h1.73 kW
- Median of 6,000 Btu central models at 5°F
- 5,900 Btu/h1.73 kW
- Models in this group
- 134
This unit is above 30% of them, at number 94 of 134 by heat at 5°F. The middle half of the group runs 4,500 to 5,900 Btu/h.
Among 6,000 Btu central models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 33rd of 134 (tied); HSPF2, 33rd of 134 (tied). Models without that figure are left out.
Similar ratings at 47°F
These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.
Closest models by heat at 5°F
Every 6,000 Btu unit, ranked by cooling efficiency, then heating efficiency
Floor area at the cold test point
The median certified output of 5,900 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.
| Climate band | House condition | Btu/h per sq ft | Approximate sq ft |
|---|---|---|---|
| Mild | Drafty, little insulation | 24–42 | 140–250 |
| Mild | Typical | 16–26 | 230–370 |
| Mild | Tight, well insulated | 10–18 | 330–590 |
| Cold | Drafty, little insulation | 28–52 | 110–210 |
| Cold | Typical | 18–30 | 200–330 |
| Cold | Tight, well insulated | 12–22 | 270–490 |
| Very cold | Drafty, little insulation | 32–58 | 100–180 |
| Very cold | Typical | 22–38 | 160–270 |
| Very cold | Tight, well insulated | 16–28 | 210–370 |
This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.
Certified values for ACK09N3H1
2 pairings · 2 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 8,200 Btu/h2.40 kWNR | 8,200 Btu/h2.40 kW |
| Heat output at 17°F full speed | 7,800 Btu/h2.29 kWNR | 7,800 Btu/h2.29 kW |
| Heat output at 5°F full speed | 5,900 Btu/h1.73 kWNR | 5,900 Btu/h1.73 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 72%NR | |
| COP at 5°F full speed | 1.75NR | 1.75 |
| HSPF2 Region IV | 9.2NR | 9.2 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 6,100 Btu/h1.79 kWNR | 6,100 Btu/h1.79 kW |
| EER2 at 95°F | 11.56NR | 11.56 |
| SEER2 cooling season | 15.3NR | 15.3 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-32 | |
| Compressor | Variable speed | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | ACK09N3H1 | |
Pairings, by indoor-unit class
2 certified pairings
One row per indoor unit certified with this outdoor unit.
Unspecified
-
None listed (the pairing on screen) brand not stated 5,900 Btu/h1.73 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | — | 5,9001.73 | 8,2002.40 | 6,1001.79 | 72% | 1.75 | Yes | 2 |
Sold as, and units with identical certified values
Brands listing this model number
Other brands that list these model numbers
Model number as listed
- ACK09N3H1 2 pairings
Variants of the same model number
62 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- ACK09N3H2Ephoca · Innova
- ACK09R3H1Ephoca · Innova
- ACK09R3H2Ephoca · Innova
- ACU09N3H1Ephoca · Innova
- ACU09N3H2Ephoca · Innova
- ACU09R3H1Ephoca · Innova
- ACU09R3H2Ephoca · Innova
- ACV09N3H1Ephoca · Innova
- ACV09N3H2Ephoca · Innova
- ACV09R3H1Ephoca · Innova
- ACV09R3H2Ephoca · Innova
- ADE09N3H1Ephoca · Innova
- ADE09N3H2Ephoca · Innova
- ADE09N4H2Ephoca · Innova
- ADE09R3H1Ephoca · Innova
- ADE09R3H2Ephoca · Innova
- ADE09R4H2Ephoca · Innova
- ADK09N3H1Ephoca · Innova
- ADK09N3H2Ephoca · Innova
- ADK09N4H2Ephoca · Innova
- ADK09R3H1Ephoca · Innova
- ADK09R3H2Ephoca · Innova
- ADK09R4H2Ephoca · Innova
- ADL09N3H1Ephoca · Innova
- ADL09N3H2Ephoca · Innova
- ADL09R3H1Ephoca · Innova
- ADL09R3H2Ephoca · Innova
- ADP09N3H1Ephoca · Innova
- ADP09N3H2Ephoca · Innova
- ADP09N4H1Ephoca · Innova
- ADP09N4H2Ephoca · Innova
- ADP09R3H1Ephoca · Innova
- ADP09R3H2Ephoca · Innova
- ADP09R4H1Ephoca · Innova
- ADP09R4H2Ephoca · Innova
- ADU09N3H1Ephoca · Innova
- ADU09N3H2Ephoca · Innova
- ADU09R3H1Ephoca · Innova
- ADU09R3H2Ephoca · Innova
- ADV09N3H1Ephoca · Innova
- ADV09N3H2Ephoca · Innova
- ADV09R3H1Ephoca · Innova
- ADV09R3H2Ephoca · Innova
- ASE09N3H1Ephoca · Innova
- ASE09N3H2Ephoca · Innova
- ASE09N4H2Ephoca · Innova
- ASE09R3H2Ephoca · Innova
- ASE09R4H2Ephoca · Innova
- ASK09H4H2Ephoca · Innova
- ASK09N3H1Ephoca · Innova
- ASK09N3H2Ephoca · Innova
- ASK09R3H2Ephoca · Innova
- ASK09R4H2Ephoca · Innova
- ASP09N3H1Ephoca · Innova
- ASP09N3H2Ephoca · Innova
- ASP09N4H1Ephoca · Innova
- ASP09N4H2Ephoca · Innova
- ASP09R3H1Ephoca · Innova
- ASP09R3H2Ephoca · Innova
- ASP09R4H1Ephoca · Innova
- ASP09R4H2Ephoca · Innova
61 of 62 shown.
Other model numbers with identical certified values
62 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- ACK09N3H2identical certified values
- ACK09R3H1identical certified values
- ACK09R3H2identical certified values
- ACU09N3H1identical certified values
- ACU09N3H2identical certified values
- ACU09R3H1identical certified values
- ACU09R3H2identical certified values
- ACV09N3H1identical certified values
- ACV09N3H2identical certified values
- ACV09R3H1identical certified values
- ACV09R3H2identical certified values
- ADE09N3H1identical certified values
- ADE09N3H2identical certified values
- ADE09N4H2identical certified values
- ADE09R3H1identical certified values
- ADE09R3H2identical certified values
- ADE09R4H2identical certified values
- ADK09N3H1identical certified values
- ADK09N3H2identical certified values
- ADK09N4H2identical certified values
- ADK09R3H1identical certified values
- ADK09R3H2identical certified values
- ADK09R4H2identical certified values
- ADL09N3H1identical certified values
- ADL09N3H2identical certified values
- ADL09R3H1identical certified values
- ADL09R3H2identical certified values
- ADP09N3H1identical certified values
- ADP09N3H2identical certified values
- ADP09N4H1identical certified values
- ADP09N4H2identical certified values
- ADP09R3H1identical certified values
- ADP09R3H2identical certified values
- ADP09R4H1identical certified values
- ADP09R4H2identical certified values
- ADU09N3H1identical certified values
- ADU09N3H2identical certified values
- ADU09R3H1identical certified values
- ADU09R3H2identical certified values
- ADV09N3H1identical certified values
- ADV09N3H2identical certified values
- ADV09R3H1identical certified values
- ADV09R3H2identical certified values
- ASE09N3H1identical certified values
- ASE09N3H2identical certified values
- ASE09N4H2identical certified values
- ASE09R3H2identical certified values
- ASE09R4H2identical certified values
- ASK09H4H2identical certified values
- ASK09N3H1identical certified values
- ASK09N3H2identical certified values
- ASK09R3H2identical certified values
- ASK09R4H2identical certified values
- ASP09N3H1identical certified values
- ASP09N3H2identical certified values
- ASP09N4H1identical certified values
- ASP09N4H2identical certified values
- ASP09R3H1identical certified values
- ASP09R3H2identical certified values
- ASP09R4H1identical certified values
- ASP09R4H2identical certified values
61 of 62 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Mar 26, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read