AO-09U3R26E2
Hisense · mini-split heat pump
AO-09U3R26E2 is in the certified data as of Sep 19, 2026.
- 9,000 Btu
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
9,0002.64NR
No 47°F rating for this pairing.
6,5001.90NR at 17°F
5,4001.58NR at 5°F
Btu/hkW, certified
2.10NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 9,000 Btu/h2.64 kW of heat at 47°F, 6,500 Btu/h1.90 kW at 17°F, and 5,400 Btu/h1.58 kW at 5°F, 60% of its 47°F rating. It delivers 9,000 Btu/h2.64 kW of cooling at 95°F. At 5°F that is 2,100 Btu/h0.62 kW short of the example heating load of 7,500 Btu/h2.20 kW; at 95°F it is 5,500 Btu/h1.61 kW above the example cooling load of 3,500 Btu/h1.03 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 9,000 Btu mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 300 sq ft where winters reach 5°F: heating runs from 7,500 Btu/h2.20 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 3,500 Btu/h1.03 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 218270907 · listed by Hisense · certified Mar 26, 2026 · 1 pairing carries these values
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 5,4001.58 kW | −30% | 2.10 | |
| 17°Ffull speed | 6,5001.90 kW | −19% | NR | |
| 47°Fnormal speed | 9,0002.64 kW | −10% | NR | |
| 95°Fcooling, full load | 9,0002.64 kW | — | NR |
EER2 12.5 in that test. SEER2 22.5 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 0.75kW
- Electrical input in the 95°F cooling test
- 0.72kW
- Seasonal average heating COP
- 2.64
These exclude backup resistance heat.
How it compares with other 9,000 Btu heat pumps
9,000 Btu mini-split models
- This pairing at 5°F
- 5,400 Btu/h1.58 kWNR
- This unit at 5°F median across its pairings
- 5,400 Btu/h1.58 kW
- Median of 9,000 Btu mini-split models at 5°F
- 7,700 Btu/h2.26 kW
- Models in this group
- 894
This unit is above 1% of them, at number 887 of 894 by heat at 5°F. The middle half of the group runs 7,000 to 9,500 Btu/h.
Closest models by heat at 5°F
- RX09BXVJUDaikin · 5,800 Btu/h
- AO-09U3R25SSHisense · 5,700 Btu/h
- AST-09UW3RGE00Hisense · 5,700 Btu/h
- AO-09U3R26SSHisense · 5,400 Btu/h
- ZE-09CB22OZephyr · 5,400 Btu/h
- NTXSKS09A112AATrane / Mitsubishi Electric · 5,200 Btu/h
Every 9,000 Btu unit, ranked by cooling efficiency, then heating efficiency
Certified values for AO-09U3R26E2
1 pairing · 1 AHRI certificate
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 9,000 Btu/h2.64 kWNR | 9,000 Btu/h2.64 kW |
| Heat output at 17°F full speed | 6,500 Btu/h1.90 kWNR | 6,500 Btu/h1.90 kW |
| Heat output at 5°F full speed | 5,400 Btu/h1.58 kWNR | 5,400 Btu/h1.58 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 60%NR | |
| COP at 5°F full speed | 2.10NR | 2.10 |
| HSPF2 Region IV | 9.0NR | 9.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 9,000 Btu/h2.64 kWNR | 9,000 Btu/h2.64 kW |
| EER2 at 95°F | 12.5NR | 12.5 |
| SEER2 cooling season | 22.5NR | 22.5 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-32 | |
| Compressor | Variable speed | |
| Indoor unit | AS-09U3RHB25E | 1 indoor unit |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | AO-09U3R26E2 | |
Pairings, by indoor-unit class
1 indoor unit · 1 certified pairing
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 1 indoor unit
-
AS-09U3RHB25E (the pairing on screen) HISENSE 5,400 Btu/h1.58 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| AS-09U3RHB25E (the pairing on screen) | HISENSE | 5,4001.58 | 9,0002.64 | 9,0002.64 | 60% | 2.10 | NC | 1 |
Sold as, and units with identical certified values
Variants of the same model number
6 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- AO-09U3R25EHisense
- AST-09UW3RGU00Hisense
- CU-VST09HC-WIFIDR25Voltas
- DIRH3-09HP21-DKODirect Air
- WHS09SZB21SWestinghouse
5 of 6 shown.
Other model numbers with identical certified values
6 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- AO-09U3R25Eidentical certified values
- AST-09UW3RGU00identical certified values
- CU-VST09HC-WIFIDR25identical certified values
- DIRH3-09HP21-DKOidentical certified values
- WHS09SZB21Sidentical certified values
5 of 6 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Mar 26, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read