APP10N4H2

Ephoca and Innova · central heat pump

APP10N4H2 is in the certified data as of Sep 19, 2026.

Certified heating and cooling

Heating at 47°F

9,000

7,600 at 17°F

5,600 at 5°F

Btu/h, certified

1.76 COP at 5°F

Cooling at 95°F

9,000

Btu/h, certified

EER2 11.23 at 95°F

SEER2 15.75

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for APP10N4H2, by outdoor temperature Heating: 5,600 Btu/h at 5°F, 7,600 Btu/h at 17°F, 9,000 Btu/h at 47°F. Cooling: 9,000 Btu/h at 95°F. The bars start at zero. Median of 9,000 Btu central models: 5,600 Btu/h at 5°F, 7,600 Btu/h at 17°F, 9,000 Btu/h at 47°F, 9,000 Btu/h at 95°F. 0 2,500 5,000 7,500 10,000 Btu/h 5,600 5°F 7,600 17°F 9,000 47°F 9,000 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 9,000 Btu central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 9,000 Btu/h of heat at 47°F, 7,600 Btu/h at 17°F, and 5,600 Btu/h at 5°F, 62% of its 47°F rating. It delivers 9,000 Btu/h of cooling at 95°F. At 5°F that is 100 Btu/h above the example heating load of 5,500 Btu/h; at 95°F it is 6,000 Btu/h above the example cooling load of 3,000 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 9,000 Btu central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 250 sq ft where winters reach 5°F: heating runs from 5,500 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 3,000 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 217607131 · listed by Ephoca · certified Jan 20, 2026 · 3 pairings on 3 certificates share these values

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 9,000 Btu central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 5,6001.64 kW 0% 1.76
17°Ffull speed 7,6002.23 kW 0% NR
47°Fnormal speed 9,0002.64 kW 0% NR
95°Fcooling, full load 9,0002.64 kW — NR

EER2 11.23 in that test. SEER2 15.75 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
0.93kW
Electrical input in the 95°F cooling test
0.80kW
Seasonal average heating COP
2.51

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 9,000 Btu heat pumps

9,000 Btu central models

This pairing at 5°F
5,600 Btu/h
This unit at 5°F median across its pairings
5,600 Btu/h
Median of 9,000 Btu central models at 5°F
5,600 Btu/h
Models in this group
35

This unit is above 0% of them, at number 35 of 35 by heat at 5°F. The middle half of the group runs 5,600 to 5,600 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Closest models by heat at 5°F

Every 9,000 Btu unit, ranked by cooling efficiency, then heating efficiency

Certified values for APP10N4H2

3 pairings · 3 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for APP10N4H2
This pairingAll pairings
Heating
Heat output at 47°F normal speed 9,000 Btu/h 9,000 Btu/h
Heat output at 17°F full speed 7,600 Btu/h 7,600 Btu/h
Heat output at 5°F full speed 5,600 Btu/h 5,600 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 62%
COP at 5°F full speed 1.76 1.76
HSPF2 Region IV 8.6 8.6
Cooling
Cooling capacity at 95°F full-load test 9,000 Btu/h 9,000 Btu/h
EER2 at 95°F 11.23 11.23
SEER2 cooling season 15.75 15.75
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-32
Compressor Variable speed
Indoor unit None listed None
FurnaceNo furnace None
Cold-climate designation EPA's designation, as published Yes On every pairing
ENERGY STAR Most Efficient EPA's designation, as published No On no pairings
Where it is sold US and Canada US and Canada
Model string as certified APP10N4H2

Pairings, by indoor-unit class

3 certified pairings

One row per indoor unit certified with this outdoor unit.

Unspecified

  1. None listed (the pairing on screen) brand not stated 5,600 Btu/hat 5°F, full speed

    3 pairings · 47°F 9,000 Btu/h · 95°F cooling 9,000 Btu/h · Cold output 62% · COP 1.76

Indoor units in the unspecified class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
None listed (the pairing on screen) — 5,600 9,000 9,000 62% 1.76 Yes 3

The share is heat output at 5°F divided by the 47°F rating.

Sold as, and units with identical certified values

Brands listing this model number

Other brands that list these model numbers

Model number as listed

Variants of the same model number

33 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.

32 of 33 shown.

Other model numbers with identical certified values

20 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.

19 of 20 shown.

History and definitions

History

First certified record
Most recent certified record
Measurements reported
Jan 20, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read