AR70H15CAEBX
Samsung · mini-split heat pump
AR70H15CAEBX is in the certified data as of Oct 3, 2026.
- 15,000 Btu
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
15,0004.40NR
No 47°F rating for this pairing.
13,5003.96NR at 17°F
17,3005.07NR at 5°F
Btu/hkW, certified
2.10NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 15,000 Btu/h4.40 kW of heat at 47°F, 13,500 Btu/h3.96 kW at 17°F, and 17,300 Btu/h5.07 kW at 5°F, 115% of its 47°F rating. It delivers 15,000 Btu/h4.40 kW of cooling at 95°F. At 5°F that is 3,300 Btu/h0.97 kW above the example heating load of 14,000 Btu/h4.10 kW; at 95°F it is 8,000 Btu/h2.34 kW above the example cooling load of 7,000 Btu/h2.05 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 15,000 Btu mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 600 sq ft where winters reach 5°F: heating runs from 14,000 Btu/h4.10 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 7,000 Btu/h2.05 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 218691719 · listed by Samsung · certified Jul 29, 2026 · 2 pairings on 2 certificates share these values
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 17,3005.07 kW | +24% | 2.10 | |
| 17°Ffull speed | 13,5003.96 kW | +13% | NR | |
| 47°Fnormal speed | 15,0004.40 kW | −6% | NR | |
| 95°Fcooling, full load | 15,0004.40 kW | — | NR |
EER2 14.55 in that test. SEER2 23.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 2.41kW
- Electrical input in the 95°F cooling test
- 1.03kW
- Seasonal average heating COP
- 3.28
These exclude backup resistance heat.
How it compares with other 15,000 Btu heat pumps
15,000 Btu mini-split models
- This pairing at 5°F
- 17,300 Btu/h5.07 kWNR
- This unit at 5°F median across its pairings
- 17,300 Btu/h5.07 kW
- Median of 15,000 Btu mini-split models at 5°F
- 14,000 Btu/h4.10 kW
- Models in this group
- 98
This unit is above 69% of them, at number 30 of 98 by heat at 5°F. The middle half of the group runs 12,300 to 17,500 Btu/h.
Closest models by heat at 5°F
- MO1HS-H15B-2AMidea · 17,500 Btu/h
- MOX430-15HFN10-M1XMDV · 17,500 Btu/h
- NDHAS26BA-18-ONapoleon · 17,500 Btu/h
- SUZ-AA15NLHZMitsubishi Electric · 17,000 Btu/h
- SUZ-KA15NAHZMitsubishi Electric · 16,400 Btu/h
- DM18HOS25230E3AMoovAir · 16,000 Btu/h
Every 15,000 Btu unit, ranked by cooling efficiency, then heating efficiency
Certified values for AR70H15CAEBX
2 pairings · 2 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 15,000 Btu/h4.40 kWNR | 15,000 Btu/h4.40 kW |
| Heat output at 17°F full speed | 13,500 Btu/h3.96 kWNR | 13,500 Btu/h3.96 kW |
| Heat output at 5°F full speed | 17,300 Btu/h5.07 kWNR | 17,300 Btu/h5.07 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 115%NR | |
| COP at 5°F full speed | 2.10NR | 2.10 |
| HSPF2 Region IV | 11.2NR | 11.2 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 15,000 Btu/h4.40 kWNR | 15,000 Btu/h4.40 kW |
| EER2 at 95°F | 14.55NR | 14.55 |
| SEER2 cooling season | 23.0NR | 23.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-32 | |
| Compressor | Variable speed | |
| Indoor unit | AR70H15CAEBN | 2 indoor units |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | AR70H15CAEBX | |
Pairings, by indoor-unit class
2 indoor units · 2 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 2 indoor units
-
AR70H15CACWN (the pairing on screen) SAMSUNG 17,300 Btu/h5.07 kWat 5°F, full speed
-
AR70H15CAEBN (the pairing on screen) SAMSUNG 17,300 Btu/h5.07 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| AR70H15CACWN (the pairing on screen) | SAMSUNG | 17,3005.07 | 15,0004.40 | 15,0004.40 | 115% | 2.10 | Yes | 1 |
| AR70H15CAEBN (the pairing on screen) | SAMSUNG | 17,3005.07 | 15,0004.40 | 15,0004.40 | 115% | 2.10 | Yes | 1 |
Sold as, and units with identical certified values
Variants of the same model number
4 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
3 of 4 shown.
Other model numbers with identical certified values
4 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- AR70H15CACWXidentical certified values
- MWLE015S6S-1Pidentical certified values
- MWPE015S6S-1Pidentical certified values
3 of 4 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- AR70H15CAEBX first appeared in the certified data between Oct 2, 2026 and Oct 3, 2026.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jul 29, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read