AT2239 CA
AT2239 CA is in the certified data.
Its certified ratings are 8.3 HSPF2 and 23.9 SEER2.
Atomi Smart · central heat pump
All 4 certified Atomi Smart models
AT2239 CA is in the certified data as of Sep 19, 2026.
- 12,000 Btu (1-ton)
- Central
- Variable speed
- Canada
Certified heating and cooling
Heating at 47°F
12,7493.74NR
No 47°F rating for this pairing.
6,7221.97NR at 17°F
——NRNR at 5°F
Btu/hkW, certified
—NRNR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 12,749 Btu/h3.74 kW of heat at 47°F and 6,722 Btu/h1.97 kW at 17°F. It delivers 12,000 Btu/h3.52 kW of cooling at 95°F. At 95°F that is 8,000 Btu/h2.34 kW above the example cooling load of 4,000 Btu/h1.17 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 350 sq ft where winters reach 5°F: heating runs from 8,000 Btu/h2.34 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 4,000 Btu/h1.17 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate · listed by Atomi Smart · certified Dec 3, 2024 · 1 pairing carries these values
Rebates where you live
Meets the recorded equipment thresholds of 1 program in 1 states, provinces, or territories:Newfoundland and Labrador (1).
All 1 programs by state and province
Newfoundland and Labrador
Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.
A utility program is for that utility's customers.
Choose location
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | NR— kW | NR | NR | |
| 17°Ffull speed | 6,7221.97 kW | −34% | NR | |
| 47°Fnormal speed | 12,7493.74 kW | −10% | NR | |
| 95°Fcooling, full load | 12,0003.52 kW | — | NR |
EER2 13.05 in that test. SEER2 23.9 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- NRkW
- Electrical input in the 95°F cooling test
- 0.92kW
- Seasonal average heating COP
- 2.42
These exclude backup resistance heat.
How it compares with other 12,000 Btu heat pumps
1-ton central models
- This pairing at 5°F
- — Btu/h— kWNRNR
- This unit at 5°F median across its pairings
- NR
- Median of 1-ton central models at 5°F
- 8,200 Btu/h2.40 kW
- Models in this group
- 36
Among 12,000 Btu central models, each by its median certified pairing, highest first: HSPF2, 38th of 39 (tied). Models without that figure are left out.
Similar ratings at 47°F
These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.
- ACIQ-12-EHPD: 13,000 Btu/h at 47°F (this model: 12,749); HSPF2 10.0 (this model: 8.25).
- ACIQ-12-EHPB: 13,000 Btu/h at 47°F (this model: 12,749); HSPF2 9.0 (this model: 8.25).
- ECO-12K: 12,000 Btu/h at 47°F (this model: 12,749); HSPF2 9.7 (this model: 8.25).
Every 12,000 Btu (1-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for AT2239 CA
1 pairing · 0 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 12,749 Btu/h3.74 kWNR | 12,749 Btu/h3.74 kW |
| Heat output at 17°F full speed | 6,722 Btu/h1.97 kWNR | 6,722 Btu/h1.97 kW |
| Heat output at 5°F full speed | — Btu/h— kWNRNR | NR |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | —%NRNR | NR |
| COP at 5°F full speed | —NRNR | — |
| HSPF2 Region IV | 8.3NR | 8.3 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 12,000 Btu/h3.52 kWNR | 12,000 Btu/h3.52 kW |
| EER2 at 95°F | 13.05NR | 13.05 |
| SEER2 cooling season | 23.9NR | 23.9 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-32 | |
| Compressor | Variable speed | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | Canada | Canada |
| Model string as certified | AT2239 CA | |
Pairings, by indoor-unit class
1 certified pairing
One row per indoor unit certified with this outdoor unit.
Unspecified
-
None listed (the pairing on screen) brand not stated NRat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | — | NR | 12,7493.74 | 12,0003.52 | NR | — | NC | 1 |
Sold as, and units with identical certified values
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- AT2239 CA first appeared in the certified data between March 2025 and May 2025.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Dec 3, 2024
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read