AVM19N4H2
Ephoca and Innova · central heat pump
AVM19N4H2 is in the certified data as of Sep 19, 2026.
- 12,000 Btu (1-ton)
- Central
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
14,2004.16NR
No 47°F rating for this pairing.
10,2002.99NR at 17°F
8,2002.40NR at 5°F
Btu/hkW, certified
2.30NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 14,200 Btu/h4.16 kW of heat at 47°F, 10,200 Btu/h2.99 kW at 17°F, and 8,200 Btu/h2.40 kW at 5°F, 58% of its 47°F rating. It delivers 11,600 Btu/h3.40 kW of cooling at 95°F. At 5°F that is 200 Btu/h0.06 kW above the example heating load of 8,000 Btu/h2.34 kW; at 95°F it is 7,600 Btu/h2.23 kW above the example cooling load of 4,000 Btu/h1.17 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 350 sq ft where winters reach 5°F: heating runs from 8,000 Btu/h2.34 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 4,000 Btu/h1.17 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 217650533 · listed by Ephoca · certified Jan 20, 2026 · 2 pairings on 2 certificates share these values
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 8,2002.40 kW | 0% | 2.30 | |
| 17°Ffull speed | 10,2002.99 kW | 0% | NR | |
| 47°Fnormal speed | 14,2004.16 kW | 0% | NR | |
| 95°Fcooling, full load | 11,6003.40 kW | — | NR |
EER2 11.7 in that test. SEER2 15.4 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 1.04kW
- Electrical input in the 95°F cooling test
- 0.99kW
- Seasonal average heating COP
- 2.70
These exclude backup resistance heat.
How it compares with other 12,000 Btu heat pumps
1-ton central models
- This pairing at 5°F
- 8,200 Btu/h2.40 kWNR
- This unit at 5°F median across its pairings
- 8,200 Btu/h2.40 kW
- Median of 1-ton central models at 5°F
- 8,200 Btu/h2.40 kW
- Models in this group
- 36
This unit is above 0% of them, at number 36 of 36 by heat at 5°F. The middle half of the group runs 8,200 to 8,625 Btu/h.
Closest models by heat at 5°F
- KUSXA121ALG · 15,000 Btu/h
- ACIQ-12-EHPD1HVAC and ACiQ · 11,200 Btu/h
- ACIQ-12-EHPB1HVAC, ACiQ + 3 more · 11,000 Btu/h
- GZV6SA121MAGoodman · 11,000 Btu/h
- 12SPV0-HP-X-DMulti MFG · 9,000 Btu/h
- CU-E12SD3UAPanasonic · 8,500 Btu/h
Every 12,000 Btu (1-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for AVM19N4H2
2 pairings · 2 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 14,200 Btu/h4.16 kWNR | 14,200 Btu/h4.16 kW |
| Heat output at 17°F full speed | 10,200 Btu/h2.99 kWNR | 10,200 Btu/h2.99 kW |
| Heat output at 5°F full speed | 8,200 Btu/h2.40 kWNR | 8,200 Btu/h2.40 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 58%NR | |
| COP at 5°F full speed | 2.30NR | 2.30 |
| HSPF2 Region IV | 9.2NR | 9.2 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 11,600 Btu/h3.40 kWNR | 11,600 Btu/h3.40 kW |
| EER2 at 95°F | 11.7NR | 11.7 |
| SEER2 cooling season | 15.4NR | 15.4 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-32 | |
| Compressor | Variable speed | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | AVM19N4H2 | |
Pairings, by indoor-unit class
2 certified pairings
One row per indoor unit certified with this outdoor unit.
Unspecified
-
None listed (the pairing on screen) brand not stated 8,200 Btu/h2.40 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | — | 8,2002.40 | 14,2004.16 | 11,6003.40 | 58% | 2.30 | Yes | 2 |
Sold as, and units with identical certified values
Brands listing this model number
Other brands that list these model numbers
Model number as listed
- AVM19N4H2 2 pairings
Variants of the same model number
26 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- AVK19N3H2Ephoca · Innova
- AVK19N4H2Ephoca · Innova
- AVK19R3H2Ephoca · Innova
- AVK19R4H2Ephoca · Innova
- AVM19N3H2Ephoca · Innova
- AVM19R3H2Ephoca · Innova
- AVM19R4H2Ephoca · Innova
- AVP19N3H1Ephoca · Innova
- AVP19N3H2Ephoca · Innova
- AVP19N4H1Ephoca · Innova
- AVP19N4H2Ephoca · Innova
- AVP19R3H1Ephoca · Innova
- AVP19R3H2Ephoca · Innova
- AVP19R4H1Ephoca · Innova
- AVP19R4H2Ephoca · Innova
- AXM19N3H2Ephoca · Innova
- AXM19R3H2Ephoca · Innova
- AXP19N3H2Ephoca · Innova
- AXP19R3H2Ephoca · Innova
- AXT19N3H2Ephoca · Innova
- AXT19R3H2Ephoca · Innova
- AXW19N3H2Ephoca · Innova
- AXW19R3H2Ephoca · Innova
- AXY19N3H2Ephoca · Innova
- AXY19R3H2Ephoca · Innova
25 of 26 shown.
Other model numbers with identical certified values
26 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- AVK19N3H2identical certified values
- AVK19N4H2identical certified values
- AVK19R3H2identical certified values
- AVK19R4H2identical certified values
- AVM19N3H2identical certified values
- AVM19R3H2identical certified values
- AVM19R4H2identical certified values
- AVP19N3H1identical certified values
- AVP19N3H2identical certified values
- AVP19N4H1identical certified values
- AVP19N4H2identical certified values
- AVP19R3H1identical certified values
- AVP19R3H2identical certified values
- AVP19R4H1identical certified values
- AVP19R4H2identical certified values
- AXM19N3H2identical certified values
- AXM19R3H2identical certified values
- AXP19N3H2identical certified values
- AXP19R3H2identical certified values
- AXT19N3H2identical certified values
- AXT19R3H2identical certified values
- AXW19N3H2identical certified values
- AXW19R3H2identical certified values
- AXY19N3H2identical certified values
- AXY19R3H2identical certified values
25 of 26 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jan 20, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read