CHF3-12CD(O)
CHF3-12CD(O) is in the certified data.
Its certified full-speed heating output at 5°F is 11,500–11,800 Btu/h3.37–3.46 kW, 94–96% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
ComfortStar · mini-split heat pump
All 81 certified ComfortStar models
CHF3-12CD(O) is in the certified data as of Sep 19, 2026. CHF3-12CD(O) changed its certified heat output at 17°F on AHRI certificate 217138370 from 10,000 Btu/h to 12,000 Btu/h in the certified data between August 2025 and September 2026.
- 12,000 Btu (1-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
12,0003.52NR
No 47°F rating for this pairing.
12,0003.52NR at 17°F
11,5003.37NR at 5°F
Btu/hkW, certified
1.80NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 12,000 Btu/h3.52 kW of heat at 47°F, 12,000 Btu/h3.52 kW at 17°F, and 11,500 Btu/h3.37 kW at 5°F, 96% of its 47°F rating. It delivers 12,000 Btu/h3.52 kW of cooling at 95°F. At 5°F that is 2,500 Btu/h0.73 kW above the example heating load of 9,000 Btu/h2.64 kW; at 95°F it is 7,000 Btu/h2.05 kW above the example cooling load of 5,000 Btu/h1.47 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 400 sq ft where winters reach 5°F: heating runs from 9,000 Btu/h2.64 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 5,000 Btu/h1.47 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 217138370 · listed by ComfortStar · certified May 28, 2026 · 1 pairing carries these values
Rebates where you live
Meets the recorded equipment thresholds of 67 programs in 35 states, provinces, or territories:Alabama (1), Arizona (1), California (3), Colorado (2), Connecticut (3), Delaware (2), Idaho (2), Illinois (1), Kentucky (1), Maine (2), Maryland (3), Massachusetts (3), Michigan (2), Minnesota (2), Mississippi (2), Nevada (1), New Hampshire (3), New Jersey (7), New York (4), Oregon (2), Pennsylvania (4), Rhode Island (3), Tennessee (1), Texas (2), Utah (1), Vermont (3), Washington (2), Wisconsin (1), British Columbia (3), Manitoba (1), New Brunswick (1), Newfoundland and Labrador (1), Nova Scotia (2), Ontario (1), Yukon (2).
All 67 programs by state and province
Alabama
Arizona
California
- California Home Electrification and Appliance Rebates
- LADWP Consumer Rebate Program
- SMUD Heating and Cooling Rebate
Colorado
Connecticut
- Energize CT Residential Air Source Heat Pump Rebate · Eversource · United Illuminating
- Energize CT Residential Energy Optimization Heat Pump Rebate · Eversource · United Illuminating
- New England Heat Pump Accelerator
Delaware
- Delaware Electric Cooperative High Efficiency Heat Pump Grant
- Energize Delaware Home Performance · Delmarva Power · Delaware Electric Cooperative · Delaware Municipal Electric Corporation · City of Dover · Chesapeake Utilities
Idaho
Illinois
Kentucky
Maine
- Efficiency Maine Low-Income Supplemental Heat Pump Rebate
- Efficiency Maine Whole-Home Heat Pump Rebates
Maryland
- BGE Smart Energy Savers Heating and Cooling
- Delmarva Power Maryland HVAC Efficiency Program
- Pepco Maryland HVAC Efficiency Program
Massachusetts
- Mass Save Air Source Heat Pump Rebates · Cape Light Compact · Eversource · National Grid · Unitil · Berkshire Gas · Liberty
- Mass Save Enhanced Heat Pump Rebates · Cape Light Compact · Eversource · National Grid · Unitil · Berkshire Gas · Liberty
- New England Heat Pump Accelerator
Michigan
Minnesota
Mississippi
- EnergyRight Home Energy Rebates · TVA EnergyRight · EPB
- Entergy Mississippi Residential Heating and Cooling
Nevada
New Hampshire
- NHEC Heat Pump Incentives · New Hampshire Electric Cooperative
- NHSaves Air-Source Heat Pump Rebates · Eversource · Liberty · Unitil
- New England Heat Pump Accelerator
New Jersey
- Atlantic City Electric Building Decarbonization
- Atlantic City Electric HVAC Efficiency Program
- JCP&L Residential HVAC Rebates
- PSE&G HVAC Instant Rebates
- PSE&G Residential Building Decarbonization
- Rockland Electric Clean Heat
- SAVEGREEN Hybrid Heat · New Jersey Natural Gas
New York
- EmPower+
- NYS Clean Heat: Central Hudson, NYSEG, RG&E, and O&R · Orange & Rockland
- NYS Clean Heat: Con Edison
- NYS Clean Heat: National Grid
Oregon
- Energy Trust of Oregon Heat Pump Incentives · Portland General Electric (PGE) · Pacific Power
- Idaho Power Heating and Cooling Efficiency Program
Pennsylvania
- Duquesne Light Instant Discount
- PECO Home Rebates for Heat Pumps
- PPL Electric Utilities Heat Pump Rebates
- Penn Energy Savers
Rhode Island
- Clean Heat Rhode Island Low to Moderate Income Incentive · Rhode Island Energy · Clear River Electric & Water District · Block Island Power Company
- New England Heat Pump Accelerator
- Rhode Island Energy Heat Pump Rebates
Tennessee
Texas
Utah
Vermont
- Burlington Electric Heat Pump Rebates · Burlington Electric Department
- Efficiency Vermont Heat Pump Discounts
- Green Mountain Power Income-Eligible Heat Pump Rebate
Washington
Wisconsin
British Columbia
- CleanBC Energy Savings Program · BC Hydro · FortisBC · municipal utilities
- Home Renovation Rebate: Heat Pump Replacing Electric Heat · BC Hydro · FortisBC · Grand Forks · Penticton · Summerland · Nelson Hydro
- Home Renovation Rebate: Northern Fuel Switch · BC Hydro · Pacific Northern Gas · FortisBC (gas)
Manitoba
New Brunswick
Newfoundland and Labrador
Nova Scotia
- Home Energy Assessment: Heat Pump Rebates · Nova Scotia Power
- Moderate Income Rebate · Nova Scotia Power
Ontario
Yukon
Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.
A utility program is for that utility's customers.
Choose location
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 11,5003.37 kW | +25% | 1.80 | |
| 17°Ffull speed | 12,0003.52 kW | +22% | NR | |
| 47°Fnormal speed | 12,0003.52 kW | 0% | NR | |
| 95°Fcooling, full load | 12,0003.52 kW | — | NR |
EER2 13.2 in that test. SEER2 24.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 1.87kW
- Electrical input in the 95°F cooling test
- 0.91kW
- Seasonal average heating COP
- 3.08
These exclude backup resistance heat.
How it compares with other 12,000 Btu heat pumps
1-ton mini-split models
- This pairing at 5°F
- 11,500 Btu/h3.37 kWNR
- This unit at 5°F median across its pairings
- 11,500 Btu/h3.37 kW
- Median of 1-ton mini-split models at 5°F
- 9,200 Btu/h2.70 kW
- Models in this group
- 888
This unit is above 76% of them, at number 216 of 888 by heat at 5°F. The middle half of the group runs 8,400 to 11,300 Btu/h.
Among 12,000 Btu mini-split models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 200th of 887 (tied); HSPF2, 286th of 895 (tied). Models without that figure are left out.
Similar ratings at 47°F
These mini-split models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.
- BM12YDIY22C: The same 12,000 Btu/h rating at 47°F; 46,000 Btu/h at 5°F (this model: 11,500).
- AOUG12LZAH1: The same 12,000 Btu/h rating at 47°F; 16,600 Btu/h at 5°F (this model: 11,500).
- DIY-12-HP-C-115C: The same 12,000 Btu/h rating at 47°F; 6,400 Btu/h at 5°F (this model: 11,500).
Closest models by heat at 5°F
- 500004492Convectair · 11,500 Btu/h
- CDHAS26BA-12-OContinental · 11,500 Btu/h
- CH-RHP12-230VOCooper&Hunter · 11,500 Btu/h
- CPPB-H12A-OCapella · 11,500 Btu/h
- DIRM4-12HXPRO28-1ZDirect Air · 11,500 Btu/h
- EDSO-12HEco Air · 11,500 Btu/h
Every 12,000 Btu (1-ton) unit, ranked by cooling efficiency, then heating efficiency
Floor area at the cold test point
The median certified output of 11,500 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.
| Climate band | House condition | Btu/h per sq ft | Approximate sq ft |
|---|---|---|---|
| Mild | Drafty, little insulation | 24–42 | 270–480 |
| Mild | Typical | 16–26 | 440–720 |
| Mild | Tight, well insulated | 10–18 | 640–1,150 |
| Cold | Drafty, little insulation | 28–52 | 220–410 |
| Cold | Typical | 18–30 | 380–640 |
| Cold | Tight, well insulated | 12–22 | 520–960 |
| Very cold | Drafty, little insulation | 32–58 | 200–360 |
| Very cold | Typical | 22–38 | 300–520 |
| Very cold | Tight, well insulated | 16–28 | 410–720 |
This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.
Certified values for CHF3-12CD(O)
2 pairings · 2 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 12,000 Btu/h3.52 kWNR | 12,000–12,500 Btu/h3.52–3.66 kW |
| Heat output at 17°F full speed | 12,000 Btu/h3.52 kWNR | 9,600–12,000 Btu/h2.81–3.52 kW |
| Heat output at 5°F full speed | 11,500 Btu/h3.37 kWNR | 11,500–11,800 Btu/h3.37–3.46 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 96%NR | |
| COP at 5°F full speed | 1.80NR | 1.80–1.90 |
| HSPF2 Region IV | 10.5NR | 10.0–10.5 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 12,000 Btu/h3.52 kWNR | 12,000 Btu/h3.52 kW |
| EER2 at 95°F | 13.2NR | 12.0–13.2 |
| SEER2 cooling season | 24.0NR | 20.0–24.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Variable speed | |
| Indoor unit | CPP3-12CD(I) | 2 indoor units |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | CHF3-12CD(O) | |
Across 2 certified pairings with 2 indoor models: heat at 5°F 11,500 Btu/h with CPP3-12CD(I) to 11,800 Btu/h with CPA3-12CD(I); HSPF2 10.0 with CPA3-12CD(I) to 10.5 with CPP3-12CD(I); SEER2 20.0 with CPA3-12CD(I) to 24.0 with CPP3-12CD(I). Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.
Pairings, by indoor-unit class
2 indoor units · 2 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 2 indoor units
-
CPA3-12CD(I) (the pairing on screen) COMFORTSTAR 11,800 Btu/h3.46 kWat 5°F, full speed
-
CPP3-12CD(I) (the pairing on screen) COMFORTSTAR 11,500 Btu/h3.37 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| CPA3-12CD(I) (the pairing on screen) | COMFORTSTAR | 11,8003.46 | 12,5003.66 | 12,0003.52 | 94% | 1.90 | Yes | 1 |
| CPP3-12CD(I) (the pairing on screen) | COMFORTSTAR | 11,5003.37 | 12,0003.52 | 12,0003.52 | 96% | 1.80 | Yes | 1 |
Sold as, and units with identical certified values
Brands listing this model number
Model number as listed
- CHF3-12CD(O) 2 pairings
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- CHF3-12CD(O) changed its certified heat output at 17°F on AHRI certificate 217138370 from 10,000 Btu/h to 12,000 Btu/h in the certified data between August 2025 and September 2026.
- CHF3-12CD(O) first appeared in the certified data between March 2025 and May 2025.
History and definitions
Other CHF Series models by nominal cooling size: CHF3-09CD(O) (9,000 Btu), CHF3-18CD(O) (18,000 Btu), CHF3-24CD(O) (24,000 Btu).
History
- First certified record
- Most recent certified record
- Measurements reported
- May 28, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read