CPP3-12CD(O)
CPP3-12CD(O) is in the certified data.
Its certified full-speed heating output at 5°F is 8,400–8,900 Btu/h2.46–2.61 kW, 70–74% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
ComfortStar · mini-split heat pump
CPP3-12CD(O) is in the certified data as of Sep 19, 2026. CPP3-12CD(O) changed its certified heat output at 17°F on AHRI certificate 216720885 from 9,600 Btu/h to 10,400 Btu/h in the certified data between August 2025 and September 2026.
- 12,000 Btu (1-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
12,0003.52NR
No 47°F rating for this pairing.
10,4003.05NR at 17°F
8,6002.52NR at 5°F
Btu/hkW, certified
2.35NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 12,000 Btu/h3.52 kW of heat at 47°F, 10,400 Btu/h3.05 kW at 17°F, and 8,600 Btu/h2.52 kW at 5°F, 72% of its 47°F rating. It delivers 12,000 Btu/h3.52 kW of cooling at 95°F. At 5°F that is 400 Btu/h0.12 kW short of the example heating load of 9,000 Btu/h2.64 kW; at 95°F it is 7,000 Btu/h2.05 kW above the example cooling load of 5,000 Btu/h1.47 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 400 sq ft where winters reach 5°F: heating runs from 9,000 Btu/h2.64 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 5,000 Btu/h1.47 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 216720885 · listed by ComfortStar · certified May 28, 2026 · 1 pairing carries these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 8,6002.52 kW | −7% | 2.35 | |
| 17°Ffull speed | 10,4003.05 kW | +6% | NR | |
| 47°Fnormal speed | 12,0003.52 kW | 0% | NR | |
| 95°Fcooling, full load | 12,0003.52 kW | — | NR |
EER2 12.2 in that test. SEER2 23.1 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 1.07kW
- Electrical input in the 95°F cooling test
- 0.98kW
- Seasonal average heating COP
- 3.37
These exclude backup resistance heat.
How it compares with other 12,000 Btu heat pumps
1-ton mini-split models
- This pairing at 5°F
- 8,600 Btu/h2.52 kWNR
- This unit at 5°F median across its pairings
- 8,600 Btu/h2.52 kW
- Median of 1-ton mini-split models at 5°F
- 9,200 Btu/h2.70 kW
- Models in this group
- 888
This unit is above 29% of them, at number 634 of 888 by heat at 5°F. The middle half of the group runs 8,400 to 11,300 Btu/h.
Closest models by heat at 5°F
- 37MARAQ12AA3Bryant, Carrier + 3 more · 8,600 Btu/h
- ACIQ-12ZS-HP230C1HVAC and ACiQ · 8,600 Btu/h
- CH-RES12-230VOCooper&Hunter · 8,600 Btu/h
- CU-YM12CBUCPanasonic · 8,600 Btu/h
- EDSO-12EEco Air · 8,600 Btu/h
- LEA12SZ26-ONovair · 8,600 Btu/h
Every 12,000 Btu (1-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for CPP3-12CD(O)
5 pairings · 5 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 12,000 Btu/h3.52 kWNR | 12,000 Btu/h3.52 kW |
| Heat output at 17°F full speed | 10,400 Btu/h3.05 kWNR | 8,500–10,400 Btu/h2.49–3.05 kW |
| Heat output at 5°F full speed | 8,600 Btu/h2.52 kWNR | 8,400–8,900 Btu/h2.46–2.61 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 72%NR | |
| COP at 5°F full speed | 2.35NR | 2.25–2.48 |
| HSPF2 Region IV | 11.5NR | 10.0–11.5 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 12,000 Btu/h3.52 kWNR | 11,500–12,000 Btu/h3.37–3.52 kW |
| EER2 at 95°F | 12.2NR | 11.7–12.5 |
| SEER2 cooling season | 23.1NR | 19.0–23.1 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Variable speed | |
| Indoor unit | CPP3-12CD(I) | 5 indoor units |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | CPP3-12CD(O) | |
Pairings, by indoor-unit class
5 indoor units · 5 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 5 indoor units
-
CPA3-12CD(I) (the pairing on screen) COMFORTSTAR 8,800 Btu/h2.58 kWat 5°F, full speed
-
CPA3H-12CD(I) (the pairing on screen) COMFORTSTAR 8,900 Btu/h2.61 kWat 5°F, full speed
-
CPP3-12CD(I) (the pairing on screen) COMFORTSTAR 8,600 Btu/h2.52 kWat 5°F, full speed
-
T1W3-12CD(I) (the pairing on screen) COMFORTSTAR 8,600 Btu/h2.52 kWat 5°F, full speed
-
TPA3-12CD(I) (the pairing on screen) COMFORTSTAR 8,400 Btu/h2.46 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| CPA3-12CD(I) (the pairing on screen) | COMFORTSTAR | 8,8002.58 | 12,0003.52 | 11,5003.37 | 73% | 2.25 | Yes | 1 |
| CPA3H-12CD(I) (the pairing on screen) | COMFORTSTAR | 8,9002.61 | 12,0003.52 | 12,0003.52 | 74% | 2.44 | Yes | 1 |
| CPP3-12CD(I) (the pairing on screen) | COMFORTSTAR | 8,6002.52 | 12,0003.52 | 12,0003.52 | 72% | 2.35 | Yes | 1 |
| T1W3-12CD(I) (the pairing on screen) | COMFORTSTAR | 8,6002.52 | 12,0003.52 | 12,0003.52 | 72% | 2.48 | Yes | 1 |
| TPA3-12CD(I) (the pairing on screen) | COMFORTSTAR | 8,4002.46 | 12,0003.52 | 12,0003.52 | 70% | 2.40 | Yes | 1 |
Sold as, and units with identical certified values
Brands listing this model number
Model number as listed
- CPP3-12CD(O) 5 pairings
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- CPP3-12CD(O) changed its certified heat output at 17°F on AHRI certificate 216720885 from 9,600 Btu/h to 10,400 Btu/h in the certified data between August 2025 and September 2026.
- CPP3-12CD(O) first appeared in the certified data between November 2024 and February 2025.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- May 28, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read