D5CMHAH30EAK
Airquest, Arcoaire + 10 more · mini-split heat pump
D5CMHAH30EAK is in the certified data as of Sep 19, 2026. D5CMHAH30EAK changed its certified heat output at 17°F on 36 pairings in the certified data between August 2025 and September 2026. The new figure is higher on all 36.
- 30,000 Btu (2.5-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
31,0009.09NR
No 47°F rating for this pairing.
34,0009.96NR at 17°F
36,00010.55NR at 5°F
Btu/hkW, certified
1.95NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 31,000 Btu/h9.09 kW of heat at 47°F, 34,000 Btu/h9.96 kW at 17°F, and 36,000 Btu/h10.55 kW at 5°F, 116% of its 47°F rating. It delivers 30,000 Btu/h8.79 kW of cooling at 95°F. At 5°F that is 11,000 Btu/h3.22 kW above the example heating load of 25,000 Btu/h7.33 kW; at 95°F it is 17,500 Btu/h5.13 kW above the example cooling load of 12,500 Btu/h3.66 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,050 sq ft where winters reach 5°F: heating runs from 25,000 Btu/h7.33 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 12,500 Btu/h3.66 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 215357143 · listed by Arcoaire · certified May 6, 2026 · 12 pairings share these values
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 36,00010.55 kW | +44% | 1.95 | |
| 17°Ffull speed | 34,0009.96 kW | +33% | NR | |
| 47°Fnormal speed | 31,0009.09 kW | +3% | NR | |
| 95°Fcooling, full load | 30,0008.79 kW | — | NR |
EER2 12.5 in that test. SEER2 19.5 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 5.41kW
- Electrical input in the 95°F cooling test
- 2.40kW
- Seasonal average heating COP
- 3.08
These exclude backup resistance heat.
How it compares with other 30,000 Btu heat pumps
2.5-ton mini-split models
- This pairing at 5°F
- 36,000 Btu/h10.55 kWNR
- This unit at 5°F median across its pairings
- 36,000 Btu/h10.55 kW
- Median of 2.5-ton mini-split models at 5°F
- 25,000 Btu/h7.33 kW
- Models in this group
- 405
This unit is above 94% of them, at number 25 of 405 by heat at 5°F. The middle half of the group runs 20,000 to 27,000 Btu/h.
Closest models by heat at 5°F
- AR36DXFUMGMXSamsung · 36,000 Btu/h
- AZ-36M422SCOAzur · 36,000 Btu/h
- CA4-36UMTOComfiAire · 36,000 Btu/h
- QOS36H2BH0AInnovair · 36,000 Btu/h
- 37MAHAQ33AA3Bryant, Carrier + 3 more · 35,000 Btu/h
- CH-RHP33-230VOCooper&Hunter · 35,000 Btu/h
Every 30,000 Btu (2.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for D5CMHAH30EAK
36 pairings · 36 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 31,000 Btu/h9.09 kWNR | 31,000 Btu/h9.09 kW |
| Heat output at 17°F full speed | 34,000 Btu/h9.96 kWNR | 34,000–35,000 Btu/h9.96–10.26 kW |
| Heat output at 5°F full speed | 36,000 Btu/h10.55 kWNR | 36,000 Btu/h10.55 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 116%NR | |
| COP at 5°F full speed | 1.95NR | 1.95–2.00 |
| HSPF2 Region IV | 10.5NR | 10.5–10.7 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 30,000 Btu/h8.79 kWNR | 30,000 Btu/h8.79 kW |
| EER2 at 95°F | 12.5NR | 12.5–13.2 |
| SEER2 cooling season | 19.5NR | 19.5–24.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Variable speed | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | D5CMHAH30EAK | |
Pairings, by indoor-unit class
36 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor
-
None listed (the pairing on screen) AIRQUEST 36,000 Btu/h10.55 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | AIRQUEST | 36,00010.55 | 31,0009.09 | 30,0008.79 | 116% | 1.98 | Yes | 36 |
Sold as, and units with identical certified values
Brands listing this model number
- Airquest3 pairings
- Arcoaire3 pairings
- Comfortmaker3 pairings
- Day & Night3 pairings
- Heil3 pairings
- Keeprite3 pairings
- Kenmore3 pairings
- LPS Legacy3 pairings
- Midea3 pairings
- Smart Comfort3 pairings
- Tempstar3 pairings
- Viessmann3 pairings
Other brands that list these model numbers
- Are Airquest and Arcoaire heat pumps the same?174 shared model numbers
- Are Airquest and Heil heat pumps the same?174 shared model numbers
- Are Airquest and Keeprite heat pumps the same?152 shared model numbers
- Are Airquest and Comfortmaker heat pumps the same?151 shared model numbers
- Are Airquest and Day & Night heat pumps the same?151 shared model numbers
- Are Airquest and Tempstar heat pumps the same?151 shared model numbers
- Are Airquest and Kenmore heat pumps the same?135 shared model numbers
- Are Airquest and Smart Comfort heat pumps the same?107 shared model numbers
Model number as listed
- D5CMHAH30EAK 36 pairings
Variants of the same model number
3 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
2 of 3 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- D5CMHAH30EAK changed its certified heat output at 17°F on 36 pairings in the certified data between August 2025 and September 2026. The new figure is higher on all 36.
- D5CMHAH30EAK first appeared in the certified data between September 2024 and November 2024.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- May 6, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read