D5CMRAH48FAK
Airquest, Arcoaire + 9 more · mini-split heat pump
D5CMRAH48FAK is in the certified data as of Sep 19, 2026. D5CMRAH48FAK changed its certified heat output at 17°F on 33 pairings in the certified data between August 2025 and September 2026. The new figure is higher on all 33.
- 48,000 Btu (4-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
47,50013.92NR
No 47°F rating for this pairing.
39,50011.58NR at 17°F
37,00010.84NR at 5°F
Btu/hkW, certified
2.05NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 47,500 Btu/h13.92 kW of heat at 47°F, 39,500 Btu/h11.58 kW at 17°F, and 37,000 Btu/h10.84 kW at 5°F, 78% of its 47°F rating. It delivers 46,000 Btu/h13.48 kW of cooling at 95°F. At 5°F that is 5,000 Btu/h1.47 kW short of the example heating load of 42,000 Btu/h12.31 kW; at 95°F it is 25,000 Btu/h7.33 kW above the example cooling load of 21,000 Btu/h6.15 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,750 sq ft where winters reach 5°F: heating runs from 42,000 Btu/h12.31 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 21,000 Btu/h6.15 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 215357186 · listed by Arcoaire · certified May 6, 2026 · 11 pairings share these values
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 37,00010.84 kW | −12% | 2.05 | |
| 17°Ffull speed | 39,50011.58 kW | +4% | NR | |
| 47°Fnormal speed | 47,50013.92 kW | −3% | NR | |
| 95°Fcooling, full load | 46,00013.48 kW | — | NR |
EER2 12.25 in that test. SEER2 22.5 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 5.29kW
- Electrical input in the 95°F cooling test
- 3.76kW
- Seasonal average heating COP
- 3.08
These exclude backup resistance heat.
How it compares with other 48,000 Btu heat pumps
4-ton mini-split models
- This pairing at 5°F
- 37,000 Btu/h10.84 kWNR
- This unit at 5°F median across its pairings
- 37,000 Btu/h10.84 kW
- Median of 4-ton mini-split models at 5°F
- 42,000 Btu/h12.31 kW
- Models in this group
- 321
This unit is above 23% of them, at number 247 of 321 by heat at 5°F. The middle half of the group runs 37,000 to 47,500 Btu/h.
Closest models by heat at 5°F
- KUMXB481ALG · 37,800 Btu/h
- 37VMB048HDS3-1Bryant, Carrier + 1 more · 37,600 Btu/h
- KUSUB481ALG · 37,400 Btu/h
- GS5M48HP230V1MOGree · 37,000 Btu/h
- MULTI6-48HP230C-OMRCOOL · 37,000 Btu/h
- TM48D6MOTosot · 37,000 Btu/h
Every 48,000 Btu (4-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for D5CMRAH48FAK
33 pairings · 33 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 47,500 Btu/h13.92 kWNR | 47,000–48,000 Btu/h13.77–14.07 kW |
| Heat output at 17°F full speed | 39,500 Btu/h11.58 kWNR | 39,000–40,000 Btu/h11.43–11.72 kW |
| Heat output at 5°F full speed | 37,000 Btu/h10.84 kWNR | 36,000–38,000 Btu/h10.55–11.14 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 78%NR | |
| COP at 5°F full speed | 2.05NR | 2.00–2.10 |
| HSPF2 Region IV | 10.5NR | 10.4–10.6 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 46,000 Btu/h13.48 kWNR | 45,000–47,000 Btu/h13.19–13.77 kW |
| EER2 at 95°F | 12.25NR | 12.0–12.5 |
| SEER2 cooling season | 22.5NR | 20.5–24.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Variable speed | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | D5CMRAH48FAK | |
Pairings, by indoor-unit class
33 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor
-
None listed (the pairing on screen) AIRQUEST 37,000 Btu/h10.84 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | AIRQUEST | 37,00010.84 | 47,50013.92 | 46,00013.48 | 78% | 2.05 | Yes | 33 |
Sold as, and units with identical certified values
Brands listing this model number
- Airquest3 pairings
- Arcoaire3 pairings
- Comfortmaker3 pairings
- Day & Night3 pairings
- Heil3 pairings
- Keeprite3 pairings
- Kenmore3 pairings
- LPS Legacy3 pairings
- Midea3 pairings
- Smart Comfort3 pairings
- Tempstar3 pairings
Other brands that list these model numbers
- Are Airquest and Arcoaire heat pumps the same?174 shared model numbers
- Are Airquest and Heil heat pumps the same?174 shared model numbers
- Are Airquest and Keeprite heat pumps the same?152 shared model numbers
- Are Airquest and Comfortmaker heat pumps the same?151 shared model numbers
- Are Airquest and Day & Night heat pumps the same?151 shared model numbers
- Are Airquest and Tempstar heat pumps the same?151 shared model numbers
- Are Airquest and Kenmore heat pumps the same?135 shared model numbers
- Are Airquest and Smart Comfort heat pumps the same?107 shared model numbers
Model number as listed
- D5CMRAH48FAK 33 pairings
Variants of the same model number
2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- D5CMRAH48FAK changed its certified heat output at 17°F on 33 pairings in the certified data between August 2025 and September 2026. The new figure is higher on all 33.
- D5CMRAH48FAK changed its certified cooling capacity at 95°F on 12 pairings from 45,000 Btu/h to 46,000 Btu/h in the certified data between September 2024 and November 2024.
- D5CMRAH48FAK changed its certified heat output at 17°F on 12 pairings from 35,400 Btu/h to 37,400 Btu/h in the certified data between September 2024 and November 2024.
- D5CMRAH48FAK was in the certified data by September 2024.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- May 6, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read