DIYHH-12-HP-C-230D25-O is in the certified data.
Its certified full-speed heating output at 5°F is 11,000–11,500 Btu/h3.22–3.37 kW, 92% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
MRCOOL · mini-split heat pump
DIYHH-12-HP-C-230D25-O is in the certified data as of Sep 19, 2026.
- 12,000 Btu (1-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
12,0003.52NR
No 47°F rating for this pairing.
8,9002.61NR at 17°F
11,0003.22NR at 5°F
Btu/hkW, certified
1.80NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 12,000 Btu/h3.52 kW of heat at 47°F, 8,900 Btu/h2.61 kW at 17°F, and 11,000 Btu/h3.22 kW at 5°F, 92% of its 47°F rating. It delivers 12,000 Btu/h3.52 kW of cooling at 95°F. At 5°F that is 2,000 Btu/h0.59 kW above the example heating load of 9,000 Btu/h2.64 kW; at 95°F it is 7,000 Btu/h2.05 kW above the example cooling load of 5,000 Btu/h1.47 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 400 sq ft where winters reach 5°F: heating runs from 9,000 Btu/h2.64 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 5,000 Btu/h1.47 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 216032549 · listed by MRCOOL · certified Mar 4, 2025 · 1 pairing carries these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 11,0003.22 kW | +20% | 1.80 | |
| 17°Ffull speed | 8,9002.61 kW | −9% | NR | |
| 47°Fnormal speed | 12,0003.52 kW | 0% | NR | |
| 95°Fcooling, full load | 12,0003.52 kW | — | NR |
EER2 12.8 in that test. SEER2 23.5 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 1.79kW
- Electrical input in the 95°F cooling test
- 0.94kW
- Seasonal average heating COP
- 2.93
These exclude backup resistance heat.
How it compares with other 12,000 Btu heat pumps
1-ton mini-split models
- This pairing at 5°F
- 11,000 Btu/h3.22 kWNR
- This unit at 5°F median across its pairings
- 11,000 Btu/h3.22 kW
- Median of 1-ton mini-split models at 5°F
- 9,200 Btu/h2.70 kW
- Models in this group
- 888
This unit is above 70% of them, at number 265 of 888 by heat at 5°F. The middle half of the group runs 8,400 to 11,300 Btu/h.
Closest models by heat at 5°F
- MSH123G22MCAAGoodman · 11,300 Btu/h
- MMLD012S6S-1PLennox · 11,200 Btu/h
- BDS3A12UC0Blueridge · 11,000 Btu/h
- EHH-O12KBBEco AC · 11,000 Btu/h
- EHP-O12BBEco AC · 11,000 Btu/h
- FPHSR12A3DFriedrich, Rheem + 1 more · 11,000 Btu/h
Every 12,000 Btu (1-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for DIYHH-12-HP-C-230D25-O
2 pairings · 2 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 12,000 Btu/h3.52 kWNR | 12,000–12,500 Btu/h3.52–3.66 kW |
| Heat output at 17°F full speed | 8,900 Btu/h2.61 kWNR | 8,900–11,900 Btu/h2.61–3.49 kW |
| Heat output at 5°F full speed | 11,000 Btu/h3.22 kWNR | 11,000–11,500 Btu/h3.22–3.37 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 92%NR | |
| COP at 5°F full speed | 1.80NR | 1.80–2.10 |
| HSPF2 Region IV | 10.0NR | 10.0–10.8 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 12,000 Btu/h3.52 kWNR | 12,000 Btu/h3.52 kW |
| EER2 at 95°F | 12.8NR | 12.5–12.8 |
| SEER2 cooling season | 23.5NR | 22.2–23.5 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Variable speed | |
| Indoor unit | DIY-12-HP-WMAH-230D25-O | 2 indoor units |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | DIYHH-12-HP-C-230D25-O | |
Pairings, by indoor-unit class
2 indoor units · 2 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 2 indoor units
-
DIY-12-HP-WMAH-230D25-O (the pairing on screen) MRCOOL 11,000 Btu/h3.22 kWat 5°F, full speed
-
DIYCASSETTE12HP-230D25-O (the pairing on screen) MRCOOL 11,500 Btu/h3.37 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| DIY-12-HP-WMAH-230D25-O (the pairing on screen) | MRCOOL | 11,0003.22 | 12,0003.52 | 12,0003.52 | 92% | 1.80 | Yes | 1 |
| DIYCASSETTE12HP-230D25-O (the pairing on screen) | MRCOOL | 11,5003.37 | 12,5003.66 | 12,0003.52 | 92% | 2.10 | Yes | 1 |
Sold as, and units with identical certified values
Brands listing this model number
Model number as listed
- DIYHH-12-HP-C-230D25-O 2 pairings
Variants of the same model number
2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
Other model numbers with identical certified values
2 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- DIYHH-12-HP-C-230D25-O first appeared in the certified data between September 2024 and November 2024.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Mar 4, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read