Heat Pump List

Tools

DRU1H18S2A: every certified pairing

The 43 certified pairings of DRU1H18S2A, with the AHRI certificate number, the indoor unit, and the certified figures.

Back to DRU1H18S2A

Every certified pairing

Each certified record is an outdoor unit together with a named indoor unit, and a furnace where one is in the pairing. Change the indoor unit and the certified figures change.

Certified pairings of DRU1H18S2A
AHRI reference Indoor unit Furnace 5°FBtu/h 17°FBtu/h 47°FBtu/h 95°FBtu/h · cooling COPat 5°F Cold output% of 47°F rating
215374884 DRUM1824S2A — 18,000 15,000 19,000 18,000 2.00 95%
217465406 DRUF1820S2A — 19,600 15,300 19,000 18,000 2.10 103%
217493430 DRUC2414S2A — 18,000 15,200 19,000 18,000 2.06 95%
217493432 DRUC2417S2A — 18,000 15,200 19,000 18,000 2.06 95%
218071720 DRUC2417S2A RG19060B12MPS1 19,000 15,000 18,000 18,000 1.80 106%
218071735 DRUC2417S2A MGV96U060B3C 18,000 14,000 19,000 18,000 1.90 95%
218071736 DRUC2417S2A MGV96U080B3C 18,000 14,000 19,000 18,000 1.90 95%
218071766 DRUC2414S2A MGV80M040A3A 18,000 14,000 19,000 18,000 1.80 95%
218071767 DRUC2414S2A MGV80M060A3A 18,000 14,000 19,000 18,000 1.80 95%
218071769 DRUC2417S2A MGV80M080B4A 18,000 14,000 19,000 18,000 1.80 95%
218071817 DRUC2417S2A S9V2B040D3VS*** 18,000 13,000 19,000 18,000 1.80 95%
218071818 DRUC2417S2A S9V2B040U3VS*** 18,000 13,000 19,000 18,000 1.75 95%
218071819 DRUC2417S2A S9V2B060D3VS*** 18,000 13,000 19,000 18,000 1.80 95%
218071820 DRUC2417S2A S9V2B060U4VS*** 18,000 13,000 19,000 18,000 1.75 95%
218071821 DRUC2417S2A S9V2B080D4VS*** 18,000 13,000 19,000 18,000 1.80 95%
218071822 DRUC2417S2A S9V2B080U4VS*** 18,000 13,000 19,000 18,000 1.80 95%
218071825 DRUC2417S2A S9X1B040D3PSB** 18,000 14,000 19,000 18,000 1.80 95%
218071826 DRUC2417S2A S9X1B040U3PSB** 18,000 14,000 19,000 18,000 1.80 95%
218071827 DRUC2417S2A S9X1B060D3PSB** 18,000 14,000 19,000 18,000 1.80 95%
218071939 DRUC2417S2A S9X2B040D3PSB** 18,000 14,000 19,000 18,000 1.80 95%
218071940 DRUC2417S2A S9X2B040U3PSB** 18,000 14,000 19,000 18,000 1.80 95%
218071941 DRUC2417S2A S9X2B060D3PSB** 18,000 14,000 19,000 18,000 1.80 95%
218072005 DRUC2414S2A RG19040A10MPS1 18,000 14,000 19,000 18,000 1.80 95%
218072006 DRUC2414S2A RG19060A10MPS1 18,000 14,000 19,000 18,000 1.80 95%
218072007 DRUC2417S2A RG19080B12MPS1 19,000 14,000 19,000 18,000 1.90 100%
218072062 DRUC2414S2A RL18040A12MPS1 18,000 14,000 19,000 18,000 1.80 95%
218072063 DRUC2414S2A RL18060A12MPS1 18,000 14,000 19,000 18,000 1.80 95%
218072064 DRUC2417S2A RL18080B12MPS1 19,000 14,000 19,000 18,000 1.90 100%
218072260 DRUC2417S2A ML193DF045XE36B* 18,000 14,000 19,000 18,000 1.80 95%
218072261 DRUC2417S2A ML193DF070XE36B* 18,000 14,000 19,000 18,000 1.80 95%
218072262 DRUC2417S2A ML193UH030XE36B* 17,000 13,000 19,000 18,000 1.70 89%
218072263 DRUC2417S2A ML193UH045XE36B* 18,000 14,000 19,000 18,000 1.80 95%
218072264 DRUC2417S2A ML193UH070XE36B* 18,000 14,000 19,000 18,000 1.80 95%
218072270 DRUC2417S2A ML196DF045XE36B* 18,000 14,000 19,000 18,000 1.80 95%
218072271 DRUC2417S2A ML196DF070XE48B* 18,000 14,000 19,000 18,000 1.80 95%
218072272 DRUC2417S2A ML196UH030XE36B* 18,000 14,000 19,000 18,000 1.80 95%
218072273 DRUC2417S2A ML196UH045XE36B* 18,000 14,000 19,000 18,000 1.80 95%
218072274 DRUC2417S2A ML196UH070XE36B* 18,000 14,000 19,000 18,000 1.80 95%
218072278 DRUC2417S2A ML296DF045XV36B* 18,000 14,000 19,000 18,000 1.80 95%
218072279 DRUC2417S2A ML296UH045XV36B* 18,000 14,000 19,000 18,000 1.80 95%
218072280 DRUC2417S2A ML296UH070XV36B* 19,000 14,000 19,000 18,000 1.80 100%
218679562 DRUC2417S2A DR95M4AT0401317S 18,000 14,000 19,000 18,000 1.80 95%
218679563 DRUC2417S2A DR95M4AT0601317S 19,000 14,000 19,000 18,000 1.90 100%

The share is heat output at 5°F divided by the 47°F rating. Tests use different compressor speeds.

43 of 43 certified pairings