Heat Pump List

Tools

DRU1H30S2A

DRU1H30S2A is in the certified data.

Its certified full-speed heating output at 5°F is 28,000–32,600 Btu/h, 90–107% of its 47°F rating (tests at different compressor speeds), depending on the pairing.

DuraSTAR · central heat pump

All 68 certified DuraSTAR models

DRU1H30S2A is in the certified data as of Sep 19, 2026.

49 certified pairings with 39 different figures. See all

Certified heating and cooling

Heating at 47°F

29,000

22,000 at 17°F

29,000 at 5°F

Btu/h, certified

1.80 COP at 5°F

Cooling at 95°F

29,000

Btu/h, certified

EER2 10.4 at 95°F

SEER2 15.5

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for DRU1H30S2A, by outdoor temperature Heating: 29,000 Btu/h at 5°F, 22,000 Btu/h at 17°F, 29,000 Btu/h at 47°F. Cooling: 29,000 Btu/h at 95°F. The bars start at zero. Median of 2.5-ton central models: 22,400 Btu/h at 5°F, 20,600 Btu/h at 17°F, 30,000 Btu/h at 47°F, 30,000 Btu/h at 95°F. 0 10,000 20,000 30,000 40,000 Btu/h 29,000 5°F 22,000 17°F 29,000 47°F 29,000 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 2.5-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 29,000 Btu/h of heat at 47°F, 22,000 Btu/h at 17°F, and 29,000 Btu/h at 5°F, 100% of its 47°F rating. It delivers 29,000 Btu/h of cooling at 95°F. At 5°F that is 6,500 Btu/h above the example heating load of 22,500 Btu/h; at 95°F it is 17,500 Btu/h above the example cooling load of 11,500 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 950 sq ft where winters reach 5°F: heating runs from 22,500 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 11,500 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 218071854 · listed by DuraSTAR · certified Mar 9, 2026 · 3 pairings share these values

Rebates where you live

Meets the recorded equipment thresholds of 49 programs in 30 states, provinces, or territories:Alabama (1), Arizona (1), California (3), Colorado (1), Connecticut (3), Idaho (2), Illinois (1), Kansas (1), Kentucky (1), Maryland (3), Massachusetts (3), Michigan (2), Minnesota (3), Mississippi (2), Nevada (1), New Hampshire (3), New Jersey (2), New York (4), North Carolina (1), Oregon (2), Rhode Island (3), South Carolina (1), Tennessee (1), Texas (1), Utah (1), Vermont (3), Washington (3), Wisconsin (1), British Columbia (3), Newfoundland and Labrador (1).

All 49 programs by state and province

Alabama

Arizona

California

Colorado

Connecticut

Idaho

Illinois

Kansas

Kentucky

Maryland

Massachusetts

Michigan

Minnesota

Mississippi

Nevada

New Hampshire

New Jersey

New York

North Carolina

Oregon

Rhode Island

South Carolina

Tennessee

Texas

Utah

Vermont

Washington

Wisconsin

British Columbia

Newfoundland and Labrador

Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 2.5-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 29,0008.50 kW +29% 1.80
17°Ffull speed 22,0006.45 kW +7% NR
47°Fnormal speed 29,0008.50 kW −3% NR
95°Fcooling, full load 29,0008.50 kW — NR

EER2 10.4 in that test. SEER2 15.5 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
4.72kW
Electrical input in the 95°F cooling test
2.79kW
Seasonal average heating COP
2.58

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 30,000 Btu heat pumps

2.5-ton central models

This pairing at 5°F
29,000 Btu/h
This unit at 5°F median across its pairings
29,000 Btu/h
Median of 2.5-ton central models at 5°F
22,400 Btu/h
Models in this group
288

This unit is above 73% of them, at number 79 of 288 by heat at 5°F. The middle half of the group runs 14,250 to 30,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Among 30,000 Btu central models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 27th of 288 (tied); HSPF2, 131st of 290 (tied). Models without that figure are left out.

Similar ratings at 47°F

These central models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.

  • CU-M30BAHU: The same 29,000 Btu/h rating at 47°F; 18,000 Btu/h at 5°F (this model: 29,000).
  • MVP-30-HP-C-230A00-O: The same 29,000 Btu/h rating at 47°F; 19,000 Btu/h at 5°F (this model: 29,000).
  • B5H6S30*K*AAA*: 28,800 Btu/h at 47°F (this model: 29,000); 13,500 Btu/h at 5°F (this model: 29,000).

Closest models by heat at 5°F

Every 30,000 Btu (2.5-ton) unit, ranked by cooling efficiency, then heating efficiency

Floor area at the cold test point

The median certified output of 29,000 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.

Floor area by climate band and house condition
Climate bandHouse conditionBtu/h per sq ftApproximate sq ft
MildDrafty, little insulation24–42690–1,210
MildTypical16–261,120–1,810
MildTight, well insulated10–181,610–2,900
ColdDrafty, little insulation28–52560–1,040
ColdTypical18–30970–1,610
ColdTight, well insulated12–221,320–2,420
Very coldDrafty, little insulation32–58500–910
Very coldTypical22–38760–1,320
Very coldTight, well insulated16–281,040–1,810

This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.

Certified values for DRU1H30S2A

49 pairings · 49 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for DRU1H30S2A
This pairingAll pairings
Heating
Heat output at 47°F normal speed 29,000 Btu/h 28,000–34,000 Btu/h
Heat output at 17°F full speed 22,000 Btu/h 22,000–25,000 Btu/h
Heat output at 5°F full speed 29,000 Btu/h 28,000–32,600 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 100%
COP at 5°F full speed 1.80 1.75–2.00
HSPF2 Region IV 8.8 8.1–10.2
Cooling
Cooling capacity at 95°F full-load test 29,000 Btu/h 28,000–30,000 Btu/h
EER2 at 95°F 10.4 10.0–11.7
SEER2 cooling season 15.5 15.2–17.5
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Variable speed
Indoor unit DRUC3617S2A 5 indoor units
FurnaceS9V2B060D3VS*** 44 furnaces
Cold-climate designation EPA's designation, as published Yes On every pairing
ENERGY STAR Most Efficient EPA's designation, as published No On some pairings
Where it is sold US and Canada US and Canada
Model string as certified DRU1H30S2A

Across 49 certified pairings with 5 indoor models: heat at 5°F 28,000 Btu/h with DRUC3617S2A to 32,600 Btu/h with DRUM3036S2A; HSPF2 8.1 with DRUC3621S2A to 10.2 with DRUF3022S2A; SEER2 15.2 with DRUC3621S2A to 17.5 with DRUF3022S2A. Endpoints name one indoor model where recorded; the furnace pairing can also change the figures.

Pairings, by indoor-unit class

5 indoor units · 49 certified pairings

One row per indoor unit certified with this outdoor unit.

Air handler · 5 indoor units

  1. DRUC3621S2A brand not stated 29,000 Btu/hat 5°F, full speed

    26 pairings, 25 with a furnace · 47°F 29,000 Btu/h · 95°F cooling 29,000 Btu/h · Cold output 100% · COP 1.75

  2. DRUC3617S2A (the pairing on screen) brand not stated 29,000 Btu/hat 5°F, full speed

    20 pairings, 19 with a furnace · 47°F 29,000 Btu/h · 95°F cooling 29,000 Btu/h · Cold output 100% · COP 1.75

  3. DRUC3614S2A brand not stated 30,400 Btu/hat 5°F, full speed

    1 pairing · 47°F 30,000 Btu/h · 95°F cooling 30,000 Btu/h · Cold output 101% · COP 1.80

  4. DRUF3022S2A brand not stated 32,000 Btu/hat 5°F, full speed

    1 pairing · 47°F 32,000 Btu/h · 95°F cooling 30,000 Btu/h · Cold output 100% · COP 2.00

  5. DRUM3036S2A brand not stated 32,600 Btu/hat 5°F, full speed

    1 pairing · 47°F 34,000 Btu/h · 95°F cooling 30,000 Btu/h · Cold output 96% · COP 1.96

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
DRUC3621S2A — 29,000 29,000 29,000 100% 1.75 Yes 26
DRUC3617S2A (the pairing on screen) — 29,000 29,000 29,000 100% 1.75 Yes 20
DRUC3614S2A — 30,400 30,000 30,000 101% 1.80 Yes 1
DRUF3022S2A — 32,000 32,000 30,000 100% 2.00 Yes 1
DRUM3036S2A — 32,600 34,000 30,000 96% 1.96 Yes 1

The share is heat output at 5°F divided by the 47°F rating.

Showing 5 of 5 indoor units All 49 certified pairings

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

History and definitions

Other DRU Series models by nominal cooling size: DRU1H18S2A (18,000 Btu), DRU1H24S2A (24,000 Btu), DRU1H36S2A (36,000 Btu), DRU1H42S2A (42,000 Btu), DRU1U48S2A (42,000 Btu), DRU1H49S2A (54,000 Btu).

History

First certified record
Most recent certified record
Measurements reported
Mar 9, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “DRU1H30S2A — certified heat output”. Certified figures dated , checked daily.