FH09QCA3DI-20US
FH09QCA3DI-20US is in the certified data.
Its certified full-speed heating output at 5°F is 6,700 Btu/h1.96 kW, 71% of its 47°F rating (tests at different compressor speeds) in its certified pairing.
Aufit · mini-split heat pump
FH09QCA3DI-20US is in the certified data as of Sep 19, 2026.
- 9,000 Btu
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
9,5002.78NR
No 47°F rating for this pairing.
6,0001.76NR at 17°F
6,7001.96NR at 5°F
Btu/hkW, certified
1.91NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 9,500 Btu/h2.78 kW of heat at 47°F, 6,000 Btu/h1.76 kW at 17°F, and 6,700 Btu/h1.96 kW at 5°F, 71% of its 47°F rating. It delivers 9,100 Btu/h2.67 kW of cooling at 95°F. At 5°F that is 800 Btu/h0.23 kW short of the example heating load of 7,500 Btu/h2.20 kW; at 95°F it is 5,600 Btu/h1.64 kW above the example cooling load of 3,500 Btu/h1.03 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 9,000 Btu mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 300 sq ft where winters reach 5°F: heating runs from 7,500 Btu/h2.20 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 3,500 Btu/h1.03 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 218156741 · listed by AUFIT · certified Mar 27, 2026 · 1 pairing carries these values
Rebates where you live
Meets the recorded equipment thresholds of 25 programs in 18 states, provinces, or territories:Arizona (1), California (3), Delaware (1), Idaho (1), Maryland (3), Massachusetts (2), Michigan (2), Minnesota (1), Mississippi (1), Oregon (1), Pennsylvania (1), Texas (1), Manitoba (1), New Brunswick (1), Newfoundland and Labrador (1), Nova Scotia (2), Ontario (1), Yukon (2).
All 25 programs by state and province
Arizona
California
- California Home Electrification and Appliance Rebates
- LADWP Consumer Rebate Program
- SMUD Heating and Cooling Rebate
Delaware
Idaho
Maryland
- BGE Smart Energy Savers Heating and Cooling
- Delmarva Power Maryland HVAC Efficiency Program
- Pepco Maryland HVAC Efficiency Program
Massachusetts
- Mass Save Air Source Heat Pump Rebates · Cape Light Compact · Eversource · National Grid · Unitil · Berkshire Gas · Liberty
- Mass Save Enhanced Heat Pump Rebates · Cape Light Compact · Eversource · National Grid · Unitil · Berkshire Gas · Liberty
Michigan
Minnesota
Mississippi
Oregon
Pennsylvania
Texas
Manitoba
New Brunswick
Newfoundland and Labrador
Nova Scotia
- Home Energy Assessment: Heat Pump Rebates · Nova Scotia Power
- Moderate Income Rebate · Nova Scotia Power
Ontario
Yukon
Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.
A utility program is for that utility's customers.
Choose location
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 6,7001.96 kW | −13% | 1.91 | |
| 17°Ffull speed | 6,0001.76 kW | −25% | NR | |
| 47°Fnormal speed | 9,5002.78 kW | −5% | NR | |
| 95°Fcooling, full load | 9,1002.67 kW | — | NR |
EER2 11.0 in that test. SEER2 22.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 1.03kW
- Electrical input in the 95°F cooling test
- 0.83kW
- Seasonal average heating COP
- 2.34
These exclude backup resistance heat.
How it compares with other 9,000 Btu heat pumps
9,000 Btu mini-split models
- This pairing at 5°F
- 6,700 Btu/h1.96 kWNR
- This unit at 5°F median across its pairings
- 6,700 Btu/h1.96 kW
- Median of 9,000 Btu mini-split models at 5°F
- 7,700 Btu/h2.26 kW
- Models in this group
- 894
This unit is above 13% of them, at number 781 of 894 by heat at 5°F. The middle half of the group runs 7,000 to 9,500 Btu/h.
Among 9,000 Btu mini-split models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 662nd of 894 (tied); HSPF2, 906th of 909 (tied). Models without that figure are left out.
Similar ratings at 47°F
These mini-split models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.
- YRACXJ09WHAA: The same 9,500 Btu/h rating at 47°F; 9,000 Btu/h at 5°F (this model: 6,700).
- H09SUH25XGC: The same 9,500 Btu/h rating at 47°F; 9,500 Btu/h at 5°F (this model: 6,700).
- DWA4-09KR2(US): The same 9,500 Btu/h rating at 47°F; HSPF2 10.5 (this model: 8.0).
Closest models by heat at 5°F
- ODUMOX230-09HFN1-BW0WKepler · 6,800 Btu/h
- TSH09HDI1NAN0T23TCL · 6,800 Btu/h
- AOUH09LPAS1Fujitsu · 6,700 Btu/h
- MOX230-09HFN1-BW0WMDV and Midea · 6,700 Btu/h
- MOX230-09HFN1-BW0W-9KMidea · 6,700 Btu/h
- YRACDJ09WHAAYork · 6,700 Btu/h
Every 9,000 Btu unit, ranked by cooling efficiency, then heating efficiency
Floor area at the cold test point
The median certified output of 6,700 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.
| Climate band | House condition | Btu/h per sq ft | Approximate sq ft |
|---|---|---|---|
| Mild | Drafty, little insulation | 24–42 | 160–280 |
| Mild | Typical | 16–26 | 260–420 |
| Mild | Tight, well insulated | 10–18 | 370–670 |
| Cold | Drafty, little insulation | 28–52 | 130–240 |
| Cold | Typical | 18–30 | 220–370 |
| Cold | Tight, well insulated | 12–22 | 300–560 |
| Very cold | Drafty, little insulation | 32–58 | 120–210 |
| Very cold | Typical | 22–38 | 180–300 |
| Very cold | Tight, well insulated | 16–28 | 240–420 |
This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.
Certified values for FH09QCA3DI-20US
1 pairing · 1 AHRI certificate
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 9,500 Btu/h2.78 kWNR | 9,500 Btu/h2.78 kW |
| Heat output at 17°F full speed | 6,000 Btu/h1.76 kWNR | 6,000 Btu/h1.76 kW |
| Heat output at 5°F full speed | 6,700 Btu/h1.96 kWNR | 6,700 Btu/h1.96 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 71%NR | |
| COP at 5°F full speed | 1.91NR | 1.91 |
| HSPF2 Region IV | 8.0NR | 8.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 9,100 Btu/h2.67 kWNR | 9,100 Btu/h2.67 kW |
| EER2 at 95°F | 11.0NR | 11.0 |
| SEER2 cooling season | 22.0NR | 22.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-32 | |
| Compressor | Variable speed | |
| Indoor unit | FWH09QCA3DI-20US | 1 indoor unit |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | FH09QCA3DI-20US | |
Pairings, by indoor-unit class
1 indoor unit · 1 certified pairing
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 1 indoor unit
-
FWH09QCA3DI-20US (the pairing on screen) AUFIT 6,700 Btu/h1.96 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| FWH09QCA3DI-20US (the pairing on screen) | AUFIT | 6,7001.96 | 9,5002.78 | 9,1002.67 | 71% | 1.91 | Yes | 1 |
Sold as, and units with identical certified values
Variants of the same model number
2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
Other model numbers with identical certified values
2 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
Other Q Series models by nominal cooling size: FH12QCA3DI-20US (12,000 Btu), FH18QCA2DI-20US (18,000 Btu).
History
- First certified record
- Most recent certified record
- Measurements reported
- Mar 27, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read