FPHMR27A3D
FPHMR27A3D is in the certified data.
Its certified full-speed heating output at 5°F is 26,400–27,000 Btu/h7.74–7.91 kW, 98–100% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
Friedrich, Rheem + 1 more · mini-split heat pump
FPHMR27A3D is in the certified data as of Sep 19, 2026.
- 24,000 Btu (2-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
27,0007.91NR
No 47°F rating for this pairing.
18,0005.28NR at 17°F
26,6007.80NR at 5°F
Btu/hkW, certified
1.82NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 27,000 Btu/h7.91 kW of heat at 47°F, 18,000 Btu/h5.28 kW at 17°F, and 26,600 Btu/h7.80 kW at 5°F, 99% of its 47°F rating. It delivers 27,000 Btu/h7.91 kW of cooling at 95°F. At 5°F that is 7,600 Btu/h2.23 kW above the example heating load of 19,000 Btu/h5.57 kW; at 95°F it is 17,500 Btu/h5.13 kW above the example cooling load of 9,500 Btu/h2.78 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 800 sq ft where winters reach 5°F: heating runs from 19,000 Btu/h5.57 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 9,500 Btu/h2.78 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 215792841 · listed by Friedrich · certified Feb 17, 2025 · 3 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 26,6007.80 kW | +40% | 1.82 | |
| 17°Ffull speed | 18,0005.28 kW | −10% | NR | |
| 47°Fnormal speed | 27,0007.91 kW | +8% | NR | |
| 95°Fcooling, full load | 27,0007.91 kW | — | NR |
EER2 12.2 in that test. SEER2 20.5 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 4.28kW
- Electrical input in the 95°F cooling test
- 2.21kW
- Seasonal average heating COP
- 2.75
These exclude backup resistance heat.
How it compares with other 24,000 Btu heat pumps
2-ton mini-split models
- This pairing at 5°F
- 26,600 Btu/h7.80 kWNR
- This unit at 5°F median across its pairings
- 26,600 Btu/h7.80 kW
- Median of 2-ton mini-split models at 5°F
- 19,000 Btu/h5.57 kW
- Models in this group
- 917
This unit is above 96% of them, at number 39 of 917 by heat at 5°F. The middle half of the group runs 18,000 to 23,000 Btu/h.
Closest models by heat at 5°F
- M3OK-27HFN1-MMDV · 27,000 Btu/h
- MST273G22MHAAGoodman · 27,000 Btu/h
- ZRUN024GSS0LG · 27,000 Btu/h
- ARUN024GSS4LG · 26,200 Btu/h
- PAS-24BLFASDQ1Hitachi · 26,200 Btu/h
- YPAS24BLFASDQ1York · 26,200 Btu/h
Every 24,000 Btu (2-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for FPHMR27A3D
9 pairings · 9 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 27,000 Btu/h7.91 kWNR | 27,000 Btu/h7.91 kW |
| Heat output at 17°F full speed | 18,000 Btu/h5.28 kWNR | 17,600–18,200 Btu/h5.16–5.33 kW |
| Heat output at 5°F full speed | 26,600 Btu/h7.80 kWNR | 26,400–27,000 Btu/h7.74–7.91 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 99%NR | |
| COP at 5°F full speed | 1.82NR | 1.82–1.84 |
| HSPF2 Region IV | 9.4NR | 8.8–10.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 27,000 Btu/h7.91 kWNR | 27,000 Btu/h7.91 kW |
| EER2 at 95°F | 12.2NR | 11.5–12.85 |
| SEER2 cooling season | 20.5NR | 18.0–23.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Variable speed | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | FPHMR27A3D | |
Pairings, by indoor-unit class
9 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor
-
None listed (the pairing on screen) Friedrich 26,600 Btu/h7.80 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | Friedrich | 26,6007.80 | 27,0007.91 | 27,0007.91 | 99% | 1.82 | Yes | 9 |
Sold as, and units with identical certified values
Brands listing this model number
Other brands that list these model numbers
- Are Friedrich and Rheem heat pumps the same?43 shared model numbers
- Are Friedrich and Ruud heat pumps the same?43 shared model numbers
- Are Rheem and Ruud heat pumps the same?85 shared model numbers
Model number as listed
- FPHMR27A3D 9 pairings
Variants of the same model number
9 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- AMO3-27U3T25UHisense
- AMW3-27U3TQAHisense
- HBEFLM3-OD27Endura
- HVHMZ-27V2DHaxxAir
- QOM27H2BM3AInnovair
- UMC24CN23STG1Coleman · Guardian · Luxaire
- VMTCUHC27VTS25Voltas
- ZE-527M325Zephyr
8 of 9 shown.
Other model numbers with identical certified values
2 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- FPHMR27A3D first appeared in the certified data between March 2025 and May 2025.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Feb 17, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read