GUD36W2/NHE-D(U)
AC Pro and Gree · central heat pump
GUD36W2/NHE-D(U) is in the certified data as of Sep 19, 2026. GUD36W2/NHE-D(U) changed its certified SEER2 on AHRI certificate 217120760 from 18.0 to 18.2 in the certified data between August 2025 and September 2026.
- 24,000 Btu (2-ton)
- Central
This unit's certified figures are identical to GFU36HP230V1R32AO (Gree). See the full figures, the performance chart, and a comparison with other units here:
GFU36HP230V1R32AO (main listing for GUD36W2/NHE-D(U))
Certified pairings and AHRI numbers
8 certified pairings · 6 indoor units
| AHRI certificate | Indoor unit | Furnace | Certified | At 5°FBtu/h | At 47°FBtu/h | At 95°FBtu/h · cooling |
|---|---|---|---|---|---|---|
| 214568826 | GUD36AH2/E-D(U) | No furnace | Sep 16, 2026 | 34,000 | 34,000 | 34,000 |
| 216621482 | GUD24AH2/E-D(U) | No furnace | Sep 16, 2026 | 24,000 | 25,000 | 24,000 |
| 216765692 | GCAC36F/NHA | No furnace | Jun 9, 2026 | 32,000 | 35,000 | 32,000 |
| 216768109 | GCAC24F/NHA | No furnace | Jun 9, 2026 | 24,000 | 24,000 | 23,000 |
| 217120759 | GUD24AH2/G-D(U) | No furnace | Aug 19, 2026 | 24,000 | 25,000 | 24,000 |
| 217120760 | GUD36AH2/G-D(U) | No furnace | Aug 19, 2026 | 34,000 | 34,000 | 34,000 |
| 217656861 | GUD36AH2/E-D(U) | No furnace | Sep 16, 2026 | 34,000 | 34,000 | 34,000 |
| 217656863 | GUD24AH2/E-D(U) | No furnace | Sep 16, 2026 | 24,000 | 25,000 | 24,000 |
Brands listing this model number
Product history
- GUD36W2/NHE-D(U) changed its certified SEER2 on AHRI certificate 217120760 from 18.0 to 18.2 in the certified data between August 2025 and September 2026.
- GUD36W2/NHE-D(U) changed its certified EER2 on 4 pairings in the certified data between August 2025 and September 2026. The new figure is lower on all 4.
- GUD36W2/NHE-D(U) changed its certified heat output at 5°F on 2 pairings in the certified data between August 2025 and September 2026. The new figure is higher on all 2.
- GUD36W2/NHE-D(U) changed its certified heat output at 17°F on 2 pairings in the certified data between August 2025 and September 2026. The new figure is higher on all 2.
- GUD36W2/NHE-D(U) changed its certified SEER2 on AHRI certificate 214568826 from 16.5 to 18.0 in the certified data between November 2024 and February 2025.
- GUD36W2/NHE-D(U) changed its certified HSPF2 on AHRI certificate 214568826 from 9.5 to 10.0 in the certified data between November 2024 and February 2025.
- GUD36W2/NHE-D(U) changed its certified EER2 on AHRI certificate 214568826 from 11.7 to 12.0 in the certified data between November 2024 and February 2025.
- GUD36W2/NHE-D(U) changed its certified COP at 5°F on AHRI certificate 214568826 from 1.80 to 2.00 in the certified data between November 2024 and February 2025.
- GUD36W2/NHE-D(U) changed its certified heat output at 5°F on AHRI certificate 214568826 from 32,000 Btu/h to 34,000 Btu/h in the certified data between November 2024 and February 2025.
- GUD36W2/NHE-D(U) changed its certified heat output at 17°F on AHRI certificate 214568826 from 27,000 Btu/h to 28,200 Btu/h in the certified data between November 2024 and February 2025.
- GUD36W2/NHE-D(U) was in the certified data by September 2024.