GWH09ATCXB-A6DNA1B/O
GWH09ATCXB-A6DNA1B/O is in the certified data.
Its certified full-speed heating output at 5°F is 7,700 Btu/h2.26 kW, 79% of its 47°F rating (tests at different compressor speeds) across its certified pairings.
Gree · mini-split heat pump
GWH09ATCXB-A6DNA1B/O is in the certified data as of Sep 19, 2026. GWH09ATCXB-A6DNA1B/O changed its certified heat output at 17°F on 2 pairings from 6,000 Btu/h to 8,200 Btu/h in the certified data between March 2025 and May 2025.
- 9,000 Btu
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
9,7002.84NR
No 47°F rating for this pairing.
8,2002.40NR at 17°F
7,7002.26NR at 5°F
Btu/hkW, certified
1.90NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 9,700 Btu/h2.84 kW of heat at 47°F, 8,200 Btu/h2.40 kW at 17°F, and 7,700 Btu/h2.26 kW at 5°F, 79% of its 47°F rating. It delivers 9,100 Btu/h2.67 kW of cooling at 95°F. At 5°F that is 200 Btu/h0.06 kW above the example heating load of 7,500 Btu/h2.20 kW; at 95°F it is 5,600 Btu/h1.64 kW above the example cooling load of 3,500 Btu/h1.03 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 9,000 Btu mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 300 sq ft where winters reach 5°F: heating runs from 7,500 Btu/h2.20 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 3,500 Btu/h1.03 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 214855373 · listed by GREE · certified Mar 17, 2026 · 2 pairings on 2 certificates share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 7,7002.26 kW | 0% | 1.90 | |
| 17°Ffull speed | 8,2002.40 kW | +3% | NR | |
| 47°Fnormal speed | 9,7002.84 kW | −3% | NR | |
| 95°Fcooling, full load | 9,1002.67 kW | — | NR |
EER2 12.3 in that test. SEER2 22.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 1.19kW
- Electrical input in the 95°F cooling test
- 0.74kW
- Seasonal average heating COP
- 2.70
These exclude backup resistance heat.
How it compares with other 9,000 Btu heat pumps
9,000 Btu mini-split models
- This pairing at 5°F
- 7,700 Btu/h2.26 kWNR
- This unit at 5°F median across its pairings
- 7,700 Btu/h2.26 kW
- Median of 9,000 Btu mini-split models at 5°F
- 7,700 Btu/h2.26 kW
- Models in this group
- 894
This unit is above 49% of them, at number 452 of 894 by heat at 5°F. The middle half of the group runs 7,000 to 9,500 Btu/h.
Closest models by heat at 5°F
- AUW-09U3SSHisense · 7,800 Btu/h
- EHH-O09BBEco AC · 7,800 Btu/h
- KWSM-09IR410AHS24MVKANIONco · 7,800 Btu/h
- GWH09ATCXB-D6DNA1B/OGree · 7,700 Btu/h
- KUSAC091ALG · 7,700 Btu/h
- KUSAD091ALG · 7,700 Btu/h
Every 9,000 Btu unit, ranked by cooling efficiency, then heating efficiency
Certified values for GWH09ATCXB-A6DNA1B/O
2 pairings · 2 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 9,700 Btu/h2.84 kWNR | 9,700 Btu/h2.84 kW |
| Heat output at 17°F full speed | 8,200 Btu/h2.40 kWNR | 8,200 Btu/h2.40 kW |
| Heat output at 5°F full speed | 7,700 Btu/h2.26 kWNR | 7,700 Btu/h2.26 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 79%NR | |
| COP at 5°F full speed | 1.90NR | 1.90 |
| HSPF2 Region IV | 9.2NR | 9.2 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 9,100 Btu/h2.67 kWNR | 9,100 Btu/h2.67 kW |
| EER2 at 95°F | 12.3NR | 12.3 |
| SEER2 cooling season | 22.0NR | 22.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-32 | |
| Compressor | Variable speed | |
| Indoor unit | GWH09ATCXB-A6DN***/I | 2 indoor units |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | GWH09ATCXB-A6DNA1B/O | |
Pairings, by indoor-unit class
2 indoor units · 2 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 2 indoor units
-
GWH09ATCXB-A6DN***/I (the pairing on screen) GREE 7,700 Btu/h2.26 kWat 5°F, full speed
-
GWH09AWCXB-A6DN***/I (the pairing on screen) GREE 7,700 Btu/h2.26 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| GWH09ATCXB-A6DN***/I (the pairing on screen) | GREE | 7,7002.26 | 9,7002.84 | 9,1002.67 | 79% | 1.90 | Yes | 1 |
| GWH09AWCXB-A6DN***/I (the pairing on screen) | GREE | 7,7002.26 | 9,7002.84 | 9,1002.67 | 79% | 1.90 | Yes | 1 |
Sold as, and units with identical certified values
Brands listing this model number
Model number as listed
- GWH09ATCXB-A6DNA1B/O 2 pairings
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- GWH09ATCXB-A6DNA1B/O changed its certified heat output at 17°F on 2 pairings from 6,000 Btu/h to 8,200 Btu/h in the certified data between March 2025 and May 2025.
- GWH09ATCXB-A6DNA1B/O first appeared in the certified data between September 2024 and November 2024.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Mar 17, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read