KEENUMHP12AA
KEENUMHP12AA is in the certified data.
Its certified full-speed heating output at 5°F is 11,500 Btu/h3.37 kW, 92% of its 47°F rating (tests at different compressor speeds) in its certified pairing.
KEEN Home · mini-split heat pump
KEENUMHP12AA is in the certified data as of Sep 19, 2026.
- 12,000 Btu (1-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
12,5003.66NR
No 47°F rating for this pairing.
9,6002.81NR at 17°F
11,5003.37NR at 5°F
Btu/hkW, certified
2.00NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 12,500 Btu/h3.66 kW of heat at 47°F, 9,600 Btu/h2.81 kW at 17°F, and 11,500 Btu/h3.37 kW at 5°F, 92% of its 47°F rating. It delivers 12,000 Btu/h3.52 kW of cooling at 95°F. At 5°F that is 2,500 Btu/h0.73 kW above the example heating load of 9,000 Btu/h2.64 kW; at 95°F it is 7,000 Btu/h2.05 kW above the example cooling load of 5,000 Btu/h1.47 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 400 sq ft where winters reach 5°F: heating runs from 9,000 Btu/h2.64 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 5,000 Btu/h1.47 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 217596900 · listed by KEEN Home · certified Mar 24, 2026 · 1 pairing carries these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 11,5003.37 kW | +25% | 2.00 | |
| 17°Ffull speed | 9,6002.81 kW | −2% | NR | |
| 47°Fnormal speed | 12,5003.66 kW | +4% | NR | |
| 95°Fcooling, full load | 12,0003.52 kW | — | NR |
EER2 13.0 in that test. SEER2 23.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 1.69kW
- Electrical input in the 95°F cooling test
- 0.92kW
- Seasonal average heating COP
- 2.93
These exclude backup resistance heat.
How it compares with other 12,000 Btu heat pumps
1-ton mini-split models
- This pairing at 5°F
- 11,500 Btu/h3.37 kWNR
- This unit at 5°F median across its pairings
- 11,500 Btu/h3.37 kW
- Median of 1-ton mini-split models at 5°F
- 9,200 Btu/h2.70 kW
- Models in this group
- 888
This unit is above 76% of them, at number 216 of 888 by heat at 5°F. The middle half of the group runs 8,400 to 11,300 Btu/h.
Closest models by heat at 5°F
- CPPB-H12A-OCapella · 11,500 Btu/h
- DIRM4-12HXPRO28-1ZDirect Air · 11,500 Btu/h
- EDSO-12HEco Air · 11,500 Btu/h
- ML12HP230NEXH-OMainline · 11,500 Btu/h
- MO1HS-H12B-2AMidea · 11,500 Btu/h
- MOX330-12HFN10-M1XMDV · 11,500 Btu/h
Every 12,000 Btu (1-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for KEENUMHP12AA
1 pairing · 1 AHRI certificate
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 12,500 Btu/h3.66 kWNR | 12,500 Btu/h3.66 kW |
| Heat output at 17°F full speed | 9,600 Btu/h2.81 kWNR | 9,600 Btu/h2.81 kW |
| Heat output at 5°F full speed | 11,500 Btu/h3.37 kWNR | 11,500 Btu/h3.37 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 92%NR | |
| COP at 5°F full speed | 2.00NR | 2.00 |
| HSPF2 Region IV | 10.0NR | 10.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 12,000 Btu/h3.52 kWNR | 12,000 Btu/h3.52 kW |
| EER2 at 95°F | 13.0NR | 13.0 |
| SEER2 cooling season | 23.0NR | 23.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Variable speed | |
| Indoor unit | KEENOWAH12AA | 1 indoor unit |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | KEENUMHP12AA | |
Pairings, by indoor-unit class
1 indoor unit · 1 certified pairing
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 1 indoor unit
-
KEENOWAH12AA (the pairing on screen) KEEN Home 11,500 Btu/h3.37 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| KEENOWAH12AA (the pairing on screen) | KEEN Home | 11,5003.37 | 12,5003.66 | 12,0003.52 | 92% | 2.00 | Yes | 1 |
Sold as, and units with identical certified values
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- KEENUMHP12AA first appeared in the certified data between June 2025 and August 2025.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Mar 24, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read