LEO18K30S25V220H1
LEO18K30S25V220H1 is in the certified data.
Its certified full-speed heating output at 5°F is 17,800–18,600 Btu/h5.22–5.45 kW, 74–99% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
LEO Air · mini-split heat pump
LEO18K30S25V220H1 is in the certified data as of Oct 22, 2026.
- 18,000 Btu (1.5-ton)
- Mini-split
- Variable speed
- Canada
Certified heating and cooling
Heating at 47°F
18,0005.28NR
No 47°F rating for this pairing.
15,5004.54NR at 17°F
17,8005.22NR at 5°F
Btu/hkW, certified
1.80NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 18,000 Btu/h5.28 kW of heat at 47°F, 15,500 Btu/h4.54 kW at 17°F, and 17,800 Btu/h5.22 kW at 5°F, 99% of its 47°F rating. It delivers 18,000 Btu/h5.28 kW of cooling at 95°F. At 5°F that is 3,800 Btu/h1.11 kW above the example heating load of 14,000 Btu/h4.10 kW; at 95°F it is 11,000 Btu/h3.22 kW above the example cooling load of 7,000 Btu/h2.05 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 600 sq ft where winters reach 5°F: heating runs from 14,000 Btu/h4.10 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 7,000 Btu/h2.05 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 218736944 · listed by LEO AIR · certified Oct 20, 2026 · 1 pairing carries these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 17,8005.22 kW | +25% | 1.80 | |
| 17°Ffull speed | 15,5004.54 kW | +5% | NR | |
| 47°Fnormal speed | 18,0005.28 kW | 0% | NR | |
| 95°Fcooling, full load | 18,0005.28 kW | — | NR |
EER2 12.5 in that test. SEER2 23.5 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 2.90kW
- Electrical input in the 95°F cooling test
- 1.44kW
- Seasonal average heating COP
- 2.93
These exclude backup resistance heat.
How it compares with other 18,000 Btu heat pumps
1.5-ton mini-split models
- This pairing at 5°F
- 17,800 Btu/h5.22 kWNR
- This unit at 5°F median across its pairings
- 17,800 Btu/h5.22 kW
- Median of 1.5-ton mini-split models at 5°F
- 14,200 Btu/h4.16 kW
- Models in this group
- 1,110
This unit is above 69% of them, at number 341 of 1,110 by heat at 5°F. The middle half of the group runs 13,000 to 18,000 Btu/h.
Closest models by heat at 5°F
- H18SUH23XGCTCL · 17,800 Btu/h
- INS-18K-OInoma · 17,800 Btu/h
- KWSM-24IR454BHS22.5RKANIONco · 17,800 Btu/h
- YN018GLSI25RPHPioneer · 17,800 Btu/h
- 2KARDA18SZO20Karda and PerfectAire · 17,700 Btu/h
- DIRM-18HXPRO28-1ZDirect Air · 17,700 Btu/h
Every 18,000 Btu (1.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for LEO18K30S25V220H1
2 pairings · 2 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 18,000 Btu/h5.28 kWNR | 18,000–25,000 Btu/h5.28–7.33 kW |
| Heat output at 17°F full speed | 15,500 Btu/h4.54 kWNR | 15,500–21,000 Btu/h4.54–6.15 kW |
| Heat output at 5°F full speed | 17,800 Btu/h5.22 kWNR | 17,800–18,600 Btu/h5.22–5.45 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 99%NR | |
| COP at 5°F full speed | 1.80NR | 1.80 |
| HSPF2 Region IV | 10.0NR | 9.5–10.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 18,000 Btu/h5.28 kWNR | 18,000–23,000 Btu/h5.28–6.74 kW |
| EER2 at 95°F | 12.5NR | 11.7–12.5 |
| SEER2 cooling season | 23.5NR | 23.0–23.5 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Variable speed | |
| Indoor unit | LEO18K30S25V220H1 | 1 indoor unit |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | Canada | Canada |
| Model string as certified | LEO18K30S25V220H1 | |
Pairings, by indoor-unit class
1 indoor unit · 2 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 1 indoor unit
-
LEO18K30S25V220H1 (the pairing on screen) LEO AIR 18,200 Btu/h5.33 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| LEO18K30S25V220H1 (the pairing on screen) | LEO AIR | 18,2005.33 | 21,5006.30 | 20,5006.01 | 87% | 1.80 | Yes | 2 |
Sold as, and units with identical certified values
Brands listing this model number
Model number as listed
- LEO18K30S25V220H1 1 pairing
- LEO18K30S25V220H1* 1 pairing
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- LEO18K30S25V220H1 first appeared in the certified data between Oct 21, 2026 and Oct 22, 2026.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Oct 20, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read