MMPD024S6S-1P
MMPD024S6S-1P is in the certified data.
Its certified full-speed heating output at 5°F is 21,600 Btu/h6.33 kW, 80% of its 47°F rating (tests at different compressor speeds) across its certified pairings.
Lennox · mini-split heat pump
MMPD024S6S-1P is in the certified data as of Sep 19, 2026. MMPD024S6S-1P changed its certified heat output at 47°F on 3 pairings from 24,000 Btu/h to 27,000 Btu/h in the certified data between August 2025 and September 2026.
- 24,000 Btu (2-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
27,0007.91NR
No 47°F rating for this pairing.
15,0004.40NR at 17°F
21,6006.33NR at 5°F
Btu/hkW, certified
1.80NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 27,000 Btu/h7.91 kW of heat at 47°F, 15,000 Btu/h4.40 kW at 17°F, and 21,600 Btu/h6.33 kW at 5°F, 80% of its 47°F rating. It delivers 24,000 Btu/h7.03 kW of cooling at 95°F. At 5°F that is 2,600 Btu/h0.76 kW above the example heating load of 19,000 Btu/h5.57 kW; at 95°F it is 14,500 Btu/h4.25 kW above the example cooling load of 9,500 Btu/h2.78 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 800 sq ft where winters reach 5°F: heating runs from 19,000 Btu/h5.57 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 9,500 Btu/h2.78 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 216581337 · listed by Lennox · certified Apr 27, 2026 · 1 pairing carries these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 21,6006.33 kW | +14% | 1.80 | |
| 17°Ffull speed | 15,0004.40 kW | −25% | NR | |
| 47°Fnormal speed | 27,0007.91 kW | +8% | NR | |
| 95°Fcooling, full load | 24,0007.03 kW | — | NR |
EER2 10.7 in that test. SEER2 16.6 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 3.52kW
- Electrical input in the 95°F cooling test
- 2.24kW
- Seasonal average heating COP
- 2.43
These exclude backup resistance heat.
How it compares with other 24,000 Btu heat pumps
2-ton mini-split models
- This pairing at 5°F
- 21,600 Btu/h6.33 kWNR
- This unit at 5°F median across its pairings
- 21,600 Btu/h6.33 kW
- Median of 2-ton mini-split models at 5°F
- 19,000 Btu/h5.57 kW
- Models in this group
- 917
This unit is above 64% of them, at number 332 of 917 by heat at 5°F. The middle half of the group runs 18,000 to 23,000 Btu/h.
Closest models by heat at 5°F
- GS3M24HP230V1MOGree · 21,600 Btu/h
- KUSAL241ALG · 21,600 Btu/h
- M4THM1924A13NAmeristar and RunTru · 21,600 Btu/h
- RAC-PH24WHLAEHitachi · 21,600 Btu/h
- SC-27Z-HH-M4B1HVAC, ACiQ + 2 more · 21,600 Btu/h
- TM24HX4OTosot · 21,600 Btu/h
Every 24,000 Btu (2-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for MMPD024S6S-1P
3 pairings · 3 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 27,000 Btu/h7.91 kWNR | 27,000 Btu/h7.91 kW |
| Heat output at 17°F full speed | 15,000 Btu/h4.40 kWNR | 15,000–16,800 Btu/h4.40–4.92 kW |
| Heat output at 5°F full speed | 21,600 Btu/h6.33 kWNR | 21,600 Btu/h6.33 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 80%NR | |
| COP at 5°F full speed | 1.80NR | 1.80 |
| HSPF2 Region IV | 8.3NR | 8.3–9.6 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 24,000 Btu/h7.03 kWNR | 24,000 Btu/h7.03 kW |
| EER2 at 95°F | 10.7NR | 10.7–12.0 |
| SEER2 cooling season | 16.6NR | 16.6–21.6 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-32 | |
| Compressor | Variable speed | |
| Indoor unit | MMD024S6-1P | 3 indoor units |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On some pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | MMPD024S6S-1P | |
Pairings, by indoor-unit class
3 indoor units · 3 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 3 indoor units
-
M33D024S6-1P (the pairing on screen) LENNOX 21,600 Btu/h6.33 kWat 5°F, full speed
-
MDDD024S6-1P (the pairing on screen) LENNOX 21,600 Btu/h6.33 kWat 5°F, full speed
-
MMD024S6-1P (the pairing on screen) LENNOX 21,600 Btu/h6.33 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| M33D024S6-1P (the pairing on screen) | LENNOX | 21,6006.33 | 27,0007.91 | 24,0007.03 | 80% | 1.80 | Yes | 1 |
| MDDD024S6-1P (the pairing on screen) | LENNOX | 21,6006.33 | 27,0007.91 | 24,0007.03 | 80% | 1.80 | Yes | 1 |
| MMD024S6-1P (the pairing on screen) | LENNOX | 21,6006.33 | 27,0007.91 | 24,0007.03 | 80% | 1.80 | Yes | 1 |
Sold as, and units with identical certified values
Variants of the same model number
2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
Other model numbers with identical certified values
2 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- MMPD024S6S-1P changed its certified heat output at 47°F on 3 pairings from 24,000 Btu/h to 27,000 Btu/h in the certified data between August 2025 and September 2026.
- MMPD024S6S-1P changed its certified heat output at 47°F on 3 pairings from 27,000 Btu/h to 24,000 Btu/h in the certified data between March 2025 and May 2025.
- MMPD024S6S-1P first appeared in the certified data between September 2024 and November 2024.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Apr 27, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read