MO1ES-H18B-2A
MO1ES-H18B-2A is in the certified data.
Its certified full-speed heating output at 5°F is 12,800–14,200 Btu/h3.75–4.16 kW, 70–77% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
Midea · mini-split heat pump
MO1ES-H18B-2A is in the certified data as of Sep 19, 2026. MO1ES-H18B-2A changed its certified heat output at 17°F on AHRI certificate 215471377 from 13,600 Btu/h to 15,000 Btu/h in the certified data between August 2025 and September 2026.
- 18,000 Btu (1.5-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
18,0005.28NR
No 47°F rating for this pairing.
13,2003.87NR at 17°F
13,0003.81NR at 5°F
Btu/hkW, certified
2.30NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 18,000 Btu/h5.28 kW of heat at 47°F, 13,200 Btu/h3.87 kW at 17°F, and 13,000 Btu/h3.81 kW at 5°F, 72% of its 47°F rating. It delivers 18,000 Btu/h5.28 kW of cooling at 95°F. At 5°F that is 1,000 Btu/h0.29 kW short of the example heating load of 14,000 Btu/h4.10 kW; at 95°F it is 11,000 Btu/h3.22 kW above the example cooling load of 7,000 Btu/h2.05 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 600 sq ft where winters reach 5°F: heating runs from 14,000 Btu/h4.10 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 7,000 Btu/h2.05 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 215471346 · listed by Midea · certified Mar 13, 2025 · 1 pairing carries these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 13,0003.81 kW | −8% | 2.30 | |
| 17°Ffull speed | 13,2003.87 kW | −11% | NR | |
| 47°Fnormal speed | 18,0005.28 kW | 0% | NR | |
| 95°Fcooling, full load | 18,0005.28 kW | — | NR |
EER2 12.1 in that test. SEER2 18.5 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 1.66kW
- Electrical input in the 95°F cooling test
- 1.49kW
- Seasonal average heating COP
- 2.87
These exclude backup resistance heat.
How it compares with other 18,000 Btu heat pumps
1.5-ton mini-split models
- This pairing at 5°F
- 13,000 Btu/h3.81 kWNR
- This unit at 5°F median across its pairings
- 13,000 Btu/h3.81 kW
- Median of 1.5-ton mini-split models at 5°F
- 14,200 Btu/h4.16 kW
- Models in this group
- 1,110
This unit is above 24% of them, at number 847 of 1,110 by heat at 5°F. The middle half of the group runs 13,000 to 18,000 Btu/h.
Closest models by heat at 5°F
- LISH018000P431-DLennox · 13,000 Btu/h
- MC4VHT18STGM · 13,000 Btu/h
- MHPC-H-018BSBAC Pro · 13,000 Btu/h
- MOX430-18HFN10-M1MDV · 13,000 Btu/h
- MRSVHT18ASTGM · 13,000 Btu/h
- NDHAS22BA-18-ONapoleon · 13,000 Btu/h
Every 18,000 Btu (1.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for MO1ES-H18B-2A
8 pairings · 8 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 18,000 Btu/h5.28 kWNR | 17,000–20,000 Btu/h4.98–5.86 kW |
| Heat output at 17°F full speed | 13,200 Btu/h3.87 kWNR | 13,200–15,000 Btu/h3.87–4.40 kW |
| Heat output at 5°F full speed | 13,000 Btu/h3.81 kWNR | 12,800–14,200 Btu/h3.75–4.16 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 72%NR | |
| COP at 5°F full speed | 2.30NR | 2.05–2.40 |
| HSPF2 Region IV | 9.8NR | 9.8–13.5 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 18,000 Btu/h5.28 kWNR | 16,000–18,000 Btu/h4.69–5.28 kW |
| EER2 at 95°F | 12.1NR | 12.1–13.3 |
| SEER2 cooling season | 18.5NR | 18.5–23.8 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Variable speed | |
| Indoor unit | MACHU-H18B-2A | 8 indoor units |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | MO1ES-H18B-2A | |
Pairings, by indoor-unit class
8 indoor units · 8 certified pairings
One row per indoor unit certified with this outdoor unit.
Air handler · 1 indoor unit
-
MACHU-H18B-2A (the pairing on screen) brand not stated 13,000 Btu/h3.81 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| MACHU-H18B-2A (the pairing on screen) | — | 13,0003.81 | 18,0005.28 | 18,0005.28 | 72% | 2.30 | Yes | 1 |
Ductless indoor · 7 indoor units
-
MCAHU-H18B-2A (the pairing on screen) MIDEA 13,100 Btu/h3.84 kWat 5°F, full speed
-
MCDHU-H18B-2A (the pairing on screen) MIDEA 12,800 Btu/h3.75 kWat 5°F, full speed
-
MDHHU-H18B-2A (the pairing on screen) MIDEA 14,200 Btu/h4.16 kWat 5°F, full speed
-
MDLHU-H18B-2A (the pairing on screen) MIDEA 14,000 Btu/h4.10 kWat 5°F, full speed
-
MFAHU-H16B-2A (the pairing on screen) MIDEA 13,100 Btu/h3.84 kWat 5°F, full speed
-
MFBHU-H18B-2A (the pairing on screen) MIDEA 12,800 Btu/h3.75 kWat 5°F, full speed
-
MSEHU-H18B-2A (the pairing on screen) MIDEA 12,800 Btu/h3.75 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| MCAHU-H18B-2A (the pairing on screen) | MIDEA | 13,1003.84 | 18,0005.28 | 18,0005.28 | 73% | 2.24 | Yes | 1 |
| MCDHU-H18B-2A (the pairing on screen) | MIDEA | 12,8003.75 | 18,0005.28 | 16,8004.92 | 71% | 2.20 | Yes | 1 |
| MDHHU-H18B-2A (the pairing on screen) | MIDEA | 14,2004.16 | 20,0005.86 | 17,5005.13 | 71% | 2.40 | Yes | 1 |
| MDLHU-H18B-2A (the pairing on screen) | MIDEA | 14,0004.10 | 20,0005.86 | 17,0004.98 | 70% | 2.20 | Yes | 1 |
| MFAHU-H16B-2A (the pairing on screen) | MIDEA | 13,1003.84 | 17,0004.98 | 16,0004.69 | 77% | 2.16 | Yes | 1 |
| MFBHU-H18B-2A (the pairing on screen) | MIDEA | 12,8003.75 | 18,0005.28 | 18,0005.28 | 71% | 2.05 | Yes | 1 |
| MSEHU-H18B-2A (the pairing on screen) | MIDEA | 12,8003.75 | 18,0005.28 | 18,0005.28 | 71% | 2.10 | Yes | 1 |
Sold as, and units with identical certified values
Variants of the same model number
6 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- BMS1824YCBlueridge
- BXS3A18SC0Blueridge
- CCOESBSZ17HPCustom Comfort
- MOS18H2BM0AInnovair
- SZ18H525ZMOSea Breeze
5 of 6 shown.
Other model numbers with identical certified values
4 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- BMS1824YCidentical certified values
- BXS3A18SC0identical certified values
- MOS18H2BM0Aidentical certified values
3 of 4 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- MO1ES-H18B-2A changed its certified heat output at 17°F on AHRI certificate 215471377 from 13,600 Btu/h to 15,000 Btu/h in the certified data between August 2025 and September 2026.
- MO1ES-H18B-2A was in the certified data by September 2024.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Mar 13, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read