MO3HX-H18B-2A
Midea · mini-split heat pump
MO3HX-H18B-2A is in the certified data as of Sep 19, 2026. MO3HX-H18B-2A changed its certified heat output at 17°F on 3 pairings in the certified data between August 2025 and September 2026. The new figure is higher on all 3.
- 18,000 Btu (1.5-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
20,0005.86NR
No 47°F rating for this pairing.
20,0005.86NR at 17°F
18,5005.42NR at 5°F
Btu/hkW, certified
2.00NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 20,000 Btu/h5.86 kW of heat at 47°F, 20,000 Btu/h5.86 kW at 17°F, and 18,500 Btu/h5.42 kW at 5°F, 93% of its 47°F rating. It delivers 19,000 Btu/h5.57 kW of cooling at 95°F. At 5°F that is 4,500 Btu/h1.32 kW above the example heating load of 14,000 Btu/h4.10 kW; at 95°F it is 12,000 Btu/h3.52 kW above the example cooling load of 7,000 Btu/h2.05 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 600 sq ft where winters reach 5°F: heating runs from 14,000 Btu/h4.10 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 7,000 Btu/h2.05 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 215471459 · listed by Midea · certified May 6, 2026 · 1 pairing carries these values
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 18,5005.42 kW | +30% | 2.00 | |
| 17°Ffull speed | 20,0005.86 kW | +35% | NR | |
| 47°Fnormal speed | 20,0005.86 kW | +11% | NR | |
| 95°Fcooling, full load | 19,0005.57 kW | — | NR |
EER2 14.0 in that test. SEER2 22.5 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 2.71kW
- Electrical input in the 95°F cooling test
- 1.36kW
- Seasonal average heating COP
- 2.99
These exclude backup resistance heat.
How it compares with other 18,000 Btu heat pumps
1.5-ton mini-split models
- This pairing at 5°F
- 18,500 Btu/h5.42 kWNR
- This unit at 5°F median across its pairings
- 18,500 Btu/h5.42 kW
- Median of 1.5-ton mini-split models at 5°F
- 14,200 Btu/h4.16 kW
- Models in this group
- 1,110
This unit is above 83% of them, at number 186 of 1,110 by heat at 5°F. The middle half of the group runs 13,000 to 18,000 Btu/h.
Closest models by heat at 5°F
- 2U20EH2HDHaier · 18,500 Btu/h
- 37MGHAQ18CA3Bryant, Carrier + 3 more · 18,500 Btu/h
- AOUH18KPAS1Fujitsu · 18,500 Btu/h
- MST183G22MHAAGoodman · 18,500 Btu/h
- 1U18EH2HEHaier · 18,000 Btu/h
- 37MAHAQ18AA3Bryant, Carrier + 3 more · 18,000 Btu/h
Every 18,000 Btu (1.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for MO3HX-H18B-2A
3 pairings · 3 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 20,000 Btu/h5.86 kWNR | 20,000 Btu/h5.86 kW |
| Heat output at 17°F full speed | 20,000 Btu/h5.86 kWNR | 20,000 Btu/h5.86 kW |
| Heat output at 5°F full speed | 18,500 Btu/h5.42 kWNR | 18,000–19,000 Btu/h5.28–5.57 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 93%NR | |
| COP at 5°F full speed | 2.00NR | 2.00 |
| HSPF2 Region IV | 10.2NR | 10.0–10.4 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 19,000 Btu/h5.57 kWNR | 19,000 Btu/h5.57 kW |
| EER2 at 95°F | 14.0NR | 13.0–15.0 |
| SEER2 cooling season | 22.5NR | 20.0–25.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Variable speed | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | MO3HX-H18B-2A | |
Pairings, by indoor-unit class
3 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor
-
None listed (the pairing on screen) MIDEA 18,500 Btu/h5.42 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | MIDEA | 18,5005.42 | 20,0005.86 | 19,0005.57 | 93% | 2.00 | Yes | 3 |
Sold as, and units with identical certified values
Variants of the same model number
35 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- 4C28MC318H21CanAir
- A-KHP183A-1Kerr
- A-VHP183A-1Century · Comfort-Aire
- ACIQ-18Z-HH-M3C1HVAC · ACiQ
- BMMZ18HHCBlueridge
- BMS500-AAM018-1CSXHDBosch
- BXM3A18UC0Blueridge
- BZ33-HYP183Z2-454-G3-PBreeze33
- CCOXHBMZ318HPCustom Comfort
- CH-RHP19M-230VOC&H
- CH-RVHP19M-230VOCooper&Hunter
- CPM2B1-H18A-OCapella
- CPM2B1V-H18A-OCapella
- DIRM4-18HXPRO28-2ZDirect Air
- DIRM4-18HXPRO28-3ZDirect Air
- EDMO-18HEco Air
- EDMO-18H-3GXEco Air
- EMXMZ218DAEMI
- HMZ18H525ZMOSea Breeze
- KOB-HH-PS218HP-2AAMAKaden
- KOB-HH-PS318HP-2AAMAKaden
- LEA20MZ3P36-ONovair
- M3OD31-18HFN10-M1X-DMDV
- M3OD31-18HFN10-M1XD-DMDV
- ML18HP230MULH - OMainline
- MO3GX-H18B-2AMidea
- MOM18H2BH3AInnovair
- MOM18H2BH3BInnovair
- MXHZA1832AV1MoovAir
- NDHAMBB-18-ONapoleon
- SENA-18HF-MOASenville
- SMZ2B1-H18A-OStelpro
- SMZ2B1V-H18A-OStelpro
- T55-MULTI18E454Maxi Air
34 of 35 shown.
Other model numbers with identical certified values
30 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- 4C28MC318H21identical certified values
- A-KHP183A-1identical certified values
- BMMZ18HHCidentical certified values
- BMS500-AAM018-1CSXHDidentical certified values
- BXM3A18UC0identical certified values
- BZ33-HYP183Z2-454-G3-Pidentical certified values
- CCOXHBMZ318HPidentical certified values
- CH-RHP19M-230VOidentical certified values
- CH-RVHP19M-230VOidentical certified values
- CPM2B1-H18A-Oidentical certified values
- CPM2B1V-H18A-Oidentical certified values
- DIRM4-18HXPRO28-2Zidentical certified values
- DIRM4-18HXPRO28-3Zidentical certified values
- EDMO-18Hidentical certified values
- EDMO-18H-3GXidentical certified values
- EMXMZ218DAidentical certified values
- HMZ18H525ZMOidentical certified values
- KOB-HH-PS218HP-2AAMAidentical certified values
- KOB-HH-PS318HP-2AAMAidentical certified values
- LEA20MZ3P36-Oidentical certified values
- MO3GX-H18B-2Aidentical certified values
- MOM18H2BH3Aidentical certified values
- MOM18H2BH3Bidentical certified values
- MXHZA1832AV1identical certified values
- NDHAMBB-18-Oidentical certified values
- SENA-18HF-MOAidentical certified values
- SMZ2B1-H18A-Oidentical certified values
- SMZ2B1V-H18A-Oidentical certified values
- T55-MULTI18E454identical certified values
29 of 30 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- MO3HX-H18B-2A changed its certified heat output at 17°F on 3 pairings in the certified data between August 2025 and September 2026. The new figure is higher on all 3.
- MO3HX-H18B-2A was in the certified data by September 2024.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- May 6, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read