MO5EX-H36B-2A
Midea · mini-split heat pump
MO5EX-H36B-2A is in the certified data as of Sep 19, 2026. MO5EX-H36B-2A changed its certified heat output at 17°F on 3 pairings in the certified data between August 2025 and September 2026. The new figure is higher on all 3.
- 36,000 Btu (3-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
37,00010.84NR
No 47°F rating for this pairing.
28,4008.32NR at 17°F
26,0007.62NR at 5°F
Btu/hkW, certified
2.00NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 37,000 Btu/h10.84 kW of heat at 47°F, 28,400 Btu/h8.32 kW at 17°F, and 26,000 Btu/h7.62 kW at 5°F, 70% of its 47°F rating. It delivers 35,000 Btu/h10.26 kW of cooling at 95°F. At 5°F that is 5,000 Btu/h1.47 kW short of the example heating load of 31,000 Btu/h9.09 kW; at 95°F it is 19,500 Btu/h5.71 kW above the example cooling load of 15,500 Btu/h4.54 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,300 sq ft where winters reach 5°F: heating runs from 31,000 Btu/h9.09 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 15,500 Btu/h4.54 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 215471449 · listed by Midea · certified May 6, 2026 · 1 pairing carries these values
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 26,0007.62 kW | −16% | 2.00 | |
| 17°Ffull speed | 28,4008.32 kW | −4% | NR | |
| 47°Fnormal speed | 37,00010.84 kW | 0% | NR | |
| 95°Fcooling, full load | 35,00010.26 kW | — | NR |
EER2 11.7 in that test. SEER2 20.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 3.81kW
- Electrical input in the 95°F cooling test
- 2.99kW
- Seasonal average heating COP
- 2.70
These exclude backup resistance heat.
How it compares with other 36,000 Btu heat pumps
3-ton mini-split models
- This pairing at 5°F
- 26,000 Btu/h7.62 kWNR
- This unit at 5°F median across its pairings
- 26,000 Btu/h7.62 kW
- Median of 3-ton mini-split models at 5°F
- 31,000 Btu/h9.09 kW
- Models in this group
- 553
This unit is above 24% of them, at number 422 of 553 by heat at 5°F. The middle half of the group runs 26,000 to 36,000 Btu/h.
Closest models by heat at 5°F
- GMS1D4 PROGarvee · 26,000 Btu/h
- M5OD30-36HFN10-M1DMDV · 26,000 Btu/h
- ML36HP230MUL - OMainline · 26,000 Btu/h
- YRAMX36N4HAAYork · 26,000 Btu/h
- AM4-H36/2DR3AAUX · 25,600 Btu/h
- ACIQ-36Z-E-M4ACiQ · 25,400 Btu/h
Every 36,000 Btu (3-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for MO5EX-H36B-2A
3 pairings · 3 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 37,000 Btu/h10.84 kWNR | 37,000 Btu/h10.84 kW |
| Heat output at 17°F full speed | 28,400 Btu/h8.32 kWNR | 28,400–31,000 Btu/h8.32–9.09 kW |
| Heat output at 5°F full speed | 26,000 Btu/h7.62 kWNR | 26,000 Btu/h7.62 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 70%NR | |
| COP at 5°F full speed | 2.00NR | 2.00 |
| HSPF2 Region IV | 9.2NR | 9.2–9.5 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 35,000 Btu/h10.26 kWNR | 35,000–36,000 Btu/h10.26–10.55 kW |
| EER2 at 95°F | 11.7NR | 11.7–12.0 |
| SEER2 cooling season | 20.0NR | 20.0–24.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Variable speed | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | MO5EX-H36B-2A | |
Pairings, by indoor-unit class
3 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor
-
None listed (the pairing on screen) MIDEA 26,000 Btu/h7.62 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | MIDEA | 26,0007.62 | 37,00010.84 | 35,40010.37 | 70% | 2.00 | Yes | 3 |
Sold as, and units with identical certified values
Variants of the same model number
24 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- 37MGRAQ36EA3Bryant · Carrier · Midea · Payne · WeatherMaker
- BMMZ36CBlueridge
- BMS500-AAM036-1CSXRDBosch
- BXM1A36SC0Blueridge
- BZ33-HP365Z2-454-G3-PBreeze33
- CCOESBMZ536HPCustom Comfort
- CH-R36MES-230VOCooper&Hunter
- D5CMRAH36EAKAirquest · Arcoaire · Comfortmaker · Day & Night · Heil · Keeprite · Kenmore · LPS Legacy · Midea · Smart Comfort · Tempstar
- DIRM4-36DA25-4ZDirect Air
- DIRM4-36DA25-5ZDirect Air
- EDMO-36EEco Air
- EDMO-36E-5GXEco Air
- ES-36Z-M5C1HVAC · ACiQ
- KOB-PS436HP-2AAMAKaden
- KOB-PS536HP-2AAMAKaden
- M5OD30-36HFN10-M1PMidea
- MHPC-H-036BMBAC Pro
- MO5DX-H36B-2AMidea
- MOM36H2BM5AInnovair
- MOM36H2BM5BInnovair
- MULTI5-36HP230C-OMRCOOL
- MXHSA3652AV1MoovAir
- MZ36H525ZMOSea Breeze
23 of 24 shown.
Other model numbers with identical certified values
21 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- BMMZ36Cidentical certified values
- BMS500-AAM036-1CSXRDidentical certified values
- BXM1A36SC0identical certified values
- BZ33-HP365Z2-454-G3-Pidentical certified values
- CCOESBMZ536HPidentical certified values
- CH-R36MES-230VOidentical certified values
- DIRM4-36DA25-4Zidentical certified values
- DIRM4-36DA25-5Zidentical certified values
- EDMO-36Eidentical certified values
- EDMO-36E-5GXidentical certified values
- KOB-PS436HP-2AAMAidentical certified values
- KOB-PS536HP-2AAMAidentical certified values
- M5OD30-36HFN10-M1Pidentical certified values
- MHPC-H-036BMBidentical certified values
- MO5DX-H36B-2Aidentical certified values
- MOM36H2BM5Aidentical certified values
- MOM36H2BM5Bidentical certified values
- MULTI5-36HP230C-Oidentical certified values
- MXHSA3652AV1identical certified values
- MZ36H525ZMOidentical certified values
20 of 21 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- MO5EX-H36B-2A changed its certified heat output at 17°F on 3 pairings in the certified data between August 2025 and September 2026. The new figure is higher on all 3.
- MO5EX-H36B-2A was in the certified data by September 2024.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- May 6, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read