Heat Pump List

Tools

MOD30-33HFN10-M1X

MOD30-33HFN10-M1X is in the certified data.

Its certified full-speed heating output at 5°F is 34,000–35,000 Btu/h, 96–97% of its 47°F rating (tests at different compressor speeds), depending on the pairing.

MDV · mini-split heat pump

MOD30-33HFN10-M1X is in the certified data as of Sep 24, 2026. MOD30-33HFN10-M1X changed its certified heat output at 17°F on AHRI certificate 214855421 from 30,000 Btu/h to 32,000 Btu/h in the certified data between Sep 23, 2026 and Sep 24, 2026.

5 certified pairings with 5 different figures. See all

Certified heating and cooling

Heating at 47°F

36,000

31,000 at 17°F

34,600 at 5°F

Btu/h, certified

1.91 COP at 5°F

Cooling at 95°F

33,000

Btu/h, certified

EER2 11.7 at 95°F

SEER2 20.0

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for MOD30-33HFN10-M1X, by outdoor temperature Heating: 34,600 Btu/h at 5°F, 31,000 Btu/h at 17°F, 36,000 Btu/h at 47°F. Cooling: 33,000 Btu/h at 95°F. The bars start at zero. Median of 2.5-ton mini-split models: 25,000 Btu/h at 5°F, 25,600 Btu/h at 17°F, 30,000 Btu/h at 47°F, 30,000 Btu/h at 95°F. 0 10,000 20,000 30,000 40,000 Btu/h 34,600 5°F 31,000 17°F 36,000 47°F 33,000 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 2.5-ton mini-split models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 36,000 Btu/h of heat at 47°F, 31,000 Btu/h at 17°F, and 34,600 Btu/h at 5°F, 96% of its 47°F rating. It delivers 33,000 Btu/h of cooling at 95°F. At 5°F that is 9,600 Btu/h above the example heating load of 25,000 Btu/h; at 95°F it is 20,500 Btu/h above the example cooling load of 12,500 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 1,050 sq ft where winters reach 5°F: heating runs from 25,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 12,500 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 214861336 · listed by MDV · certified May 6, 2026 · 1 pairing carries these values

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 2.5-ton mini-split models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 34,60010.14 kW +38% 1.91
17°Ffull speed 31,0009.09 kW +21% NR
47°Fnormal speed 36,00010.55 kW +20% NR
95°Fcooling, full load 33,0009.67 kW — NR

EER2 11.7 in that test. SEER2 20.0 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
5.31kW
Electrical input in the 95°F cooling test
2.82kW
Seasonal average heating COP
3.08

These exclude backup resistance heat.

Updated Sep 24, 2026 · Methodology

How it compares with other 30,000 Btu heat pumps

2.5-ton mini-split models

This pairing at 5°F
34,600 Btu/h
This unit at 5°F median across its pairings
34,600 Btu/h
Median of 2.5-ton mini-split models at 5°F
25,000 Btu/h
Models in this group
405

This unit is above 85% of them, at number 61 of 405 by heat at 5°F. The middle half of the group runs 20,000 to 27,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Closest models by heat at 5°F

Every 30,000 Btu (2.5-ton) unit, ranked by cooling efficiency, then heating efficiency

Certified values for MOD30-33HFN10-M1X

5 pairings · 5 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for MOD30-33HFN10-M1X
This pairingAll pairings
Heating
Heat output at 47°F normal speed 36,000 Btu/h 35,000–36,000 Btu/h
Heat output at 17°F full speed 31,000 Btu/h 27,400–32,000 Btu/h
Heat output at 5°F full speed 34,600 Btu/h 34,000–35,000 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 96%
COP at 5°F full speed 1.91 1.91–2.00
HSPF2 Region IV 10.5 10.0–10.5
Cooling
Cooling capacity at 95°F full-load test 33,000 Btu/h 33,000 Btu/h
EER2 at 95°F 11.7 11.7–12.0
SEER2 cooling season 20.0 16.5–20.0
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Variable speed
Indoor unit MSAG11F-33HRFN10-M1 5 indoor units
FurnaceNo furnace None
Cold-climate designation EPA's designation, as published Yes On every pairing
ENERGY STAR Most Efficient EPA's designation, as published Yes On every pairing
Where it is sold US and Canada US and Canada
Model string as certified MOD30-33HFN10-M1X

Pairings, by indoor-unit class

5 indoor units · 5 certified pairings

One row per indoor unit certified with this outdoor unit.

Air handler · 2 indoor units

  1. MVBC-36HWFN10-MC1 brand not stated 34,000 Btu/hat 5°F, full speed

    1 pairing · 47°F 35,000 Btu/h · 95°F cooling 33,000 Btu/h · Cold output 97% · COP 2.00

  2. MVBC-36HWFN10-MC1-D brand not stated 34,000 Btu/hat 5°F, full speed

    1 pairing · 47°F 35,000 Btu/h · 95°F cooling 33,000 Btu/h · Cold output 97% · COP 2.00

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
MVBC-36HWFN10-MC1 — 34,000 35,000 33,000 97% 2.00 Yes 1
MVBC-36HWFN10-MC1-D — 34,000 35,000 33,000 97% 2.00 Yes 1

Ductless indoor · 3 indoor units

  1. MSAG11F-33HRFN10-M1 (the pairing on screen) MDV 34,600 Btu/hat 5°F, full speed

    1 pairing · 47°F 36,000 Btu/h · 95°F cooling 33,000 Btu/h · Cold output 96% · COP 1.91

  2. MSEPD-33HRFN10-M1 MDV 35,000 Btu/hat 5°F, full speed

    1 pairing · 47°F 36,000 Btu/h · 95°F cooling 33,000 Btu/h · Cold output 97% · COP 1.98

  3. MSEPD-33HRFN10-M1-D MDV 35,000 Btu/hat 5°F, full speed

    1 pairing · 47°F 36,000 Btu/h · 95°F cooling 33,000 Btu/h · Cold output 97% · COP 1.98

Indoor units in the ductless indoor class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
MSAG11F-33HRFN10-M1 (the pairing on screen) MDV 34,600 36,000 33,000 96% 1.91 Yes 1
MSEPD-33HRFN10-M1 MDV 35,000 36,000 33,000 97% 1.98 Yes 1
MSEPD-33HRFN10-M1-D MDV 35,000 36,000 33,000 97% 1.98 Yes 1

The share is heat output at 5°F divided by the 47°F rating.

Showing 5 of 5 indoor units

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

Product history

  • MOD30-33HFN10-M1X changed its certified heat output at 17°F on AHRI certificate 214855421 from 30,000 Btu/h to 32,000 Btu/h in the certified data between Sep 23, 2026 and Sep 24, 2026.
  • MOD30-33HFN10-M1X changed its certified heat output at 17°F on 2 pairings in the certified data between August 2025 and September 2026. The new figure is higher on all 2.
  • MOD30-33HFN10-M1X changed its certified heat output at 17°F on 2 pairings from 33,400 Btu/h to 27,400 Btu/h in the certified data between November 2024 and February 2025.
  • MOD30-33HFN10-M1X was in the certified data by September 2024.

History and definitions

History

First certified record
Most recent certified record
Measurements reported
May 6, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “MOD30-33HFN10-M1X — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/mod30-33hfn10-m1x