MOE30-60HFN10-M2X
MOE30-60HFN10-M2X is in the certified data.
Its certified full-speed heating output at 5°F is 53,000–54,000 Btu/h15.53–15.83 kW, 89–90% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
MDV · mini-split heat pump
MOE30-60HFN10-M2X is in the certified data as of Sep 19, 2026.
- 54,000 Btu (4.5-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
60,00017.58NR
No 47°F rating for this pairing.
45,00013.19NR at 17°F
53,50015.68NR at 5°F
Btu/hkW, certified
2.10NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 60,000 Btu/h17.58 kW of heat at 47°F, 45,000 Btu/h13.19 kW at 17°F, and 53,500 Btu/h15.68 kW at 5°F, 89% of its 47°F rating. It delivers 55,000 Btu/h16.12 kW of cooling at 95°F. At 5°F that is 6,000 Btu/h1.76 kW above the example heating load of 47,500 Btu/h13.92 kW; at 95°F it is 31,000 Btu/h9.09 kW above the example cooling load of 24,000 Btu/h7.03 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 2,000 sq ft where winters reach 5°F: heating runs from 47,500 Btu/h13.92 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 24,000 Btu/h7.03 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 214861958 · listed by MDV · certified Mar 4, 2025 · 1 pairing carries these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 53,50015.68 kW | +13% | 2.10 | |
| 17°Ffull speed | 45,00013.19 kW | +10% | NR | |
| 47°Fnormal speed | 60,00017.58 kW | +9% | NR | |
| 95°Fcooling, full load | 55,00016.12 kW | — | NR |
EER2 10.2 in that test. SEER2 15.8 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 7.47kW
- Electrical input in the 95°F cooling test
- 5.39kW
- Seasonal average heating COP
- 3.05
These exclude backup resistance heat.
How it compares with other 54,000 Btu heat pumps
4.5-ton mini-split models
- This pairing at 5°F
- 53,500 Btu/h15.68 kWNR
- This unit at 5°F median across its pairings
- 53,500 Btu/h15.68 kW
- Median of 4.5-ton mini-split models at 5°F
- 47,500 Btu/h13.92 kW
- Models in this group
- 115
This unit is above 76% of them, at number 28 of 115 by heat at 5°F. The middle half of the group runs 46,000 to 53,000 Btu/h.
Closest models by heat at 5°F
- CH-NHPR60LCU-230VOCooper&Hunter · 53,500 Btu/h
- EDSO-60HEco Air · 53,500 Btu/h
- MO1HU-H60B-2AMidea · 53,500 Btu/h
- ACIQ-60ZPL-HP230B1HVAC, ACiQ + 3 more · 53,000 Btu/h
- SHC55VH2AGSlimAir · 53,000 Btu/h
- DRA6H55M2ADuraSTAR · 48,000 Btu/h
Every 54,000 Btu (4.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for MOE30-60HFN10-M2X
6 pairings · 6 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 60,000 Btu/h17.58 kWNR | 59,000–60,000 Btu/h17.29–17.58 kW |
| Heat output at 17°F full speed | 45,000 Btu/h13.19 kWNR | 41,000–45,000 Btu/h12.02–13.19 kW |
| Heat output at 5°F full speed | 53,500 Btu/h15.68 kWNR | 53,000–54,000 Btu/h15.53–15.83 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 89%NR | |
| COP at 5°F full speed | 2.10NR | 1.91–2.10 |
| HSPF2 Region IV | 10.4NR | 9.2–10.7 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 55,000 Btu/h16.12 kWNR | 54,000–55,000 Btu/h15.83–16.12 kW |
| EER2 at 95°F | 10.2NR | 9.0–10.2 |
| SEER2 cooling season | 15.8NR | 15.2–18.1 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Variable speed | |
| Indoor unit | MHJ-60HWFN10-M2-D | 6 indoor units |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | MOE30-60HFN10-M2X | |
Pairings, by indoor-unit class
6 indoor units · 6 certified pairings
One row per indoor unit certified with this outdoor unit.
Air handler · 2 indoor units
-
MVBC-60HWFN10-MD2 (the pairing on screen) brand not stated 53,000 Btu/h15.53 kWat 5°F, full speed
-
MVBC-60HWFN10-MD2-D (the pairing on screen) brand not stated 53,000 Btu/h15.53 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| MVBC-60HWFN10-MD2 (the pairing on screen) | — | 53,00015.53 | 59,00017.29 | 54,00015.83 | 90% | 2.00 | Yes | 1 |
| MVBC-60HWFN10-MD2-D (the pairing on screen) | — | 53,00015.53 | 59,00017.29 | 54,00015.83 | 90% | 2.00 | Yes | 1 |
Ductless indoor · 4 indoor units
-
MHJ-60HWFN10-M2 (the pairing on screen) MDV 53,500 Btu/h15.68 kWat 5°F, full speed
-
MHJ-60HWFN10-M2-D (the pairing on screen) MDV 53,500 Btu/h15.68 kWat 5°F, full speed
-
MUE-60HRFN10-M2 (the pairing on screen) MDV 54,000 Btu/h15.83 kWat 5°F, full speed
-
MUE-60HRFN10-M2-D (the pairing on screen) MDV 54,000 Btu/h15.83 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| MHJ-60HWFN10-M2 (the pairing on screen) | MDV | 53,50015.68 | 60,00017.58 | 55,00016.12 | 89% | 2.10 | Yes | 1 |
| MHJ-60HWFN10-M2-D (the pairing on screen) | MDV | 53,50015.68 | 60,00017.58 | 55,00016.12 | 89% | 2.10 | Yes | 1 |
| MUE-60HRFN10-M2 (the pairing on screen) | MDV | 54,00015.83 | 60,00017.58 | 54,00015.83 | 90% | 1.91 | Yes | 1 |
| MUE-60HRFN10-M2-D (the pairing on screen) | MDV | 54,00015.83 | 60,00017.58 | 54,00015.83 | 90% | 1.91 | Yes | 1 |
Sold as, and units with identical certified values
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Mar 4, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read