MULTI3-18HP230C-O
MULTI3-18HP230C-O is in the certified data.
Its certified full-speed heating output at 5°F is 13,500–14,600 Btu/h3.96–4.28 kW, 71–77% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
MRCOOL · mini-split heat pump
MULTI3-18HP230C-O is in the certified data as of Sep 19, 2026. MULTI3-18HP230C-O changed its certified heat output at 17°F on 3 pairings in the certified data between August 2025 and September 2026. The new figure is higher on all 3.
- 18,000 Btu (1.5-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
19,0005.57NR
No 47°F rating for this pairing.
16,0004.69NR at 17°F
14,0004.10NR at 5°F
Btu/hkW, certified
2.30NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 19,000 Btu/h5.57 kW of heat at 47°F, 16,000 Btu/h4.69 kW at 17°F, and 14,000 Btu/h4.10 kW at 5°F, 74% of its 47°F rating. It delivers 18,000 Btu/h5.28 kW of cooling at 95°F. At 5°F that matches the example heating load of 14,000 Btu/h4.10 kW; at 95°F it is 11,000 Btu/h3.22 kW above the example cooling load of 7,000 Btu/h2.05 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 600 sq ft where winters reach 5°F: heating runs from 14,000 Btu/h4.10 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 7,000 Btu/h2.05 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 217291694 · listed by MRCOOL · certified May 6, 2026 · 1 pairing carries these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 14,0004.10 kW | −1% | 2.30 | |
| 17°Ffull speed | 16,0004.69 kW | +8% | NR | |
| 47°Fnormal speed | 19,0005.57 kW | +6% | NR | |
| 95°Fcooling, full load | 18,0005.28 kW | — | NR |
EER2 13.0 in that test. SEER2 22.55 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 1.78kW
- Electrical input in the 95°F cooling test
- 1.38kW
- Seasonal average heating COP
- 2.90
These exclude backup resistance heat.
How it compares with other 18,000 Btu heat pumps
1.5-ton mini-split models
- This pairing at 5°F
- 14,000 Btu/h4.10 kWNR
- This unit at 5°F median across its pairings
- 14,000 Btu/h4.10 kW
- Median of 1.5-ton mini-split models at 5°F
- 14,200 Btu/h4.16 kW
- Models in this group
- 1,110
This unit is above 43% of them, at number 630 of 1,110 by heat at 5°F. The middle half of the group runs 13,000 to 18,000 Btu/h.
Closest models by heat at 5°F
- H18FMH24XQCTCL · 14,000 Btu/h
- M3OX430-18HFN10-M1MDV · 14,000 Btu/h
- ML18HP230MUL - OMainline · 14,000 Btu/h
- RV-18M2/O-RRovsun · 14,000 Btu/h
- SAK-18-DT2/220VStar Air Kontrol · 14,000 Btu/h
- YRAMG18N2HAAYork · 14,000 Btu/h
Every 18,000 Btu (1.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for MULTI3-18HP230C-O
3 pairings · 3 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 19,000 Btu/h5.57 kWNR | 19,000 Btu/h5.57 kW |
| Heat output at 17°F full speed | 16,000 Btu/h4.69 kWNR | 16,000 Btu/h4.69 kW |
| Heat output at 5°F full speed | 14,000 Btu/h4.10 kWNR | 13,500–14,600 Btu/h3.96–4.28 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 74%NR | |
| COP at 5°F full speed | 2.30NR | 2.30 |
| HSPF2 Region IV | 9.9NR | 9.8–10.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 18,000 Btu/h5.28 kWNR | 18,000 Btu/h5.28 kW |
| EER2 at 95°F | 13.0NR | 12.0–14.0 |
| SEER2 cooling season | 22.55NR | 20.0–25.1 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Variable speed | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | MULTI3-18HP230C-O | |
Pairings, by indoor-unit class
3 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor
-
None listed (the pairing on screen) MRCOOL 14,000 Btu/h4.10 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | MRCOOL | 14,0004.10 | 19,0005.57 | 18,0005.28 | 74% | 2.30 | Yes | 3 |
Sold as, and units with identical certified values
Brands listing this model number
Model number as listed
- MULTI3-18HP230C-O 3 pairings
Variants of the same model number
22 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- 4C25MC318H21CanAir
- BMMZ18CBlueridge
- BMS500-AAM018-1CSXRDBosch
- BXM1A18SC0Blueridge
- BZ33-HP183Z2-454-G3-PBreeze33
- CCOESBMZ318HPCustom Comfort
- CH-R18MES-230VOCooper&Hunter
- DIRM4-18DA25-2ZDirect Air
- DIRM4-18DA25-3ZDirect Air
- EDMO-18EEco Air
- EDMO-18E-3GXEco Air
- ES-18Z-M3C1HVAC · ACiQ
- KOB-PS218HP-2AAMAKaden
- KOB-PS318HP-2AAMAKaden
- LEA18MZ3P26-ONovair
- M3OX430-18HFN10-M1PMidea
- MHPC-H-018BMBAC Pro
- MO3EX-H18B-2AMidea
- MOM18H2BM3AInnovair
- MXHSA1832AN1MoovAir
- MZ18H525ZMOSea Breeze
21 of 22 shown.
Other model numbers with identical certified values
21 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
- 4C25MC318H21identical certified values
- BMMZ18Cidentical certified values
- BMS500-AAM018-1CSXRDidentical certified values
- BXM1A18SC0identical certified values
- BZ33-HP183Z2-454-G3-Pidentical certified values
- CCOESBMZ318HPidentical certified values
- CH-R18MES-230VOidentical certified values
- DIRM4-18DA25-2Zidentical certified values
- DIRM4-18DA25-3Zidentical certified values
- EDMO-18Eidentical certified values
- EDMO-18E-3GXidentical certified values
- KOB-PS218HP-2AAMAidentical certified values
- KOB-PS318HP-2AAMAidentical certified values
- LEA18MZ3P26-Oidentical certified values
- M3OX430-18HFN10-M1Pidentical certified values
- MHPC-H-018BMBidentical certified values
- MO3EX-H18B-2Aidentical certified values
- MOM18H2BM3Aidentical certified values
- MXHSA1832AN1identical certified values
- MZ18H525ZMOidentical certified values
20 of 21 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- MULTI3-18HP230C-O changed its certified heat output at 17°F on 3 pairings in the certified data between August 2025 and September 2026. The new figure is higher on all 3.
- MULTI3-18HP230C-O first appeared in the certified data between March 2025 and May 2025.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- May 6, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read