MUZ-GX18NLHZ2
Mitsubishi Electric · mini-split heat pump
MUZ-GX18NLHZ2 is in the certified data as of Sep 19, 2026.
- 18,000 Btu (1.5-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
19,0005.57NR
No 47°F rating for this pairing.
12,0003.52NR at 17°F
19,0005.57NR at 5°F
Btu/hkW, certified
1.80NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 19,000 Btu/h5.57 kW of heat at 47°F, 12,000 Btu/h3.52 kW at 17°F, and 19,000 Btu/h5.57 kW at 5°F, 100% of its 47°F rating. It delivers 18,000 Btu/h5.28 kW of cooling at 95°F. At 5°F that is 5,000 Btu/h1.47 kW above the example heating load of 14,000 Btu/h4.10 kW; at 95°F it is 11,000 Btu/h3.22 kW above the example cooling load of 7,000 Btu/h2.05 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 600 sq ft where winters reach 5°F: heating runs from 14,000 Btu/h4.10 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 7,000 Btu/h2.05 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 216801491 · listed by Mitsubishi Electric · certified Feb 17, 2025 · 1 pairing carries these values
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 19,0005.57 kW | +34% | 1.80 | |
| 17°Ffull speed | 12,0003.52 kW | −19% | NR | |
| 47°Fnormal speed | 19,0005.57 kW | +6% | NR | |
| 95°Fcooling, full load | 18,0005.28 kW | — | NR |
EER2 14.05 in that test. SEER2 22.5 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 3.09kW
- Electrical input in the 95°F cooling test
- 1.28kW
- Seasonal average heating COP
- 2.93
These exclude backup resistance heat.
How it compares with other 18,000 Btu heat pumps
1.5-ton mini-split models
- This pairing at 5°F
- 19,000 Btu/h5.57 kWNR
- This unit at 5°F median across its pairings
- 19,000 Btu/h5.57 kW
- Median of 1.5-ton mini-split models at 5°F
- 14,200 Btu/h4.16 kW
- Models in this group
- 1,110
This unit is above 88% of them, at number 135 of 1,110 by heat at 5°F. The middle half of the group runs 13,000 to 18,000 Btu/h.
Closest models by heat at 5°F
- M2OI-18HFN1-MEco Air and MDV · 19,000 Btu/h
- MSH183G32MCAAGoodman · 19,000 Btu/h
- MUZ-GS18NAHZAmerican Standard / Mitsubishi Electric, Mitsubishi Electric + 1 more · 19,000 Btu/h
- RZQ18TBVJUDaikin · 19,000 Btu/h
- 2MXL18WMVJUDaikin · 18,900 Btu/h
- CU-3E19RBU-5Panasonic · 18,900 Btu/h
Every 18,000 Btu (1.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for MUZ-GX18NLHZ2
1 pairing · 1 AHRI certificate
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 19,000 Btu/h5.57 kWNR | 19,000 Btu/h5.57 kW |
| Heat output at 17°F full speed | 12,000 Btu/h3.52 kWNR | 12,000 Btu/h3.52 kW |
| Heat output at 5°F full speed | 19,000 Btu/h5.57 kWNR | 19,000 Btu/h5.57 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 100%NR | |
| COP at 5°F full speed | 1.80NR | 1.80 |
| HSPF2 Region IV | 10.0NR | 10.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 18,000 Btu/h5.28 kWNR | 18,000 Btu/h5.28 kW |
| EER2 at 95°F | 14.05NR | 14.05 |
| SEER2 cooling season | 22.5NR | 22.5 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Variable speed | |
| Indoor unit | MSZ-GX18NL*** | 1 indoor unit |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | MUZ-GX18NLHZ2*** | |
Pairings, by indoor-unit class
1 indoor unit · 1 certified pairing
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 1 indoor unit
-
MSZ-GX18NL*** (the pairing on screen) Mitsubishi Electric 19,000 Btu/h5.57 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| MSZ-GX18NL*** (the pairing on screen) | Mitsubishi Electric | 19,0005.57 | 19,0005.57 | 18,0005.28 | 100% | 1.80 | Yes | 1 |
Sold as, and units with identical certified values
Brands listing this model number
Model number as listed
- MUZ-GX18NLHZ2*** 1 pairing
Variants of the same model number
2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
Other model numbers with identical certified values
2 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- MUZ-GX18NLHZ2 first appeared in the certified data between March 2025 and May 2025.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Feb 17, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read