MUZ-HX24NL is in the certified data.

Its certified full-speed heating output at 5°F is 18,200 Btu/h, 70% of its 47°F rating (tests at different compressor speeds) across its certified pairings.

Mitsubishi Electric · mini-split heat pump

MUZ-HX24NL is in the certified data as of Sep 19, 2026.

Certified heating and cooling

Heating at 47°F

26,000

17,200 at 17°F

18,200 at 5°F

Btu/h, certified

1.80 COP at 5°F

Cooling at 95°F

22,400

Btu/h, certified

EER2 11.75 at 95°F

SEER2 20.0

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for MUZ-HX24NL, by outdoor temperature Heating: 18,200 Btu/h at 5°F, 17,200 Btu/h at 17°F, 26,000 Btu/h at 47°F. Cooling: 22,400 Btu/h at 95°F. The bars start at zero. Median of 2-ton mini-split models: 19,000 Btu/h at 5°F, 20,000 Btu/h at 17°F, 25,000 Btu/h at 47°F, 24,000 Btu/h at 95°F. 0 10,000 20,000 30,000 Btu/h 18,200 5°F 17,200 17°F 26,000 47°F 22,400 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 2-ton mini-split models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 26,000 Btu/h of heat at 47°F, 17,200 Btu/h at 17°F, and 18,200 Btu/h at 5°F, 70% of its 47°F rating. It delivers 22,400 Btu/h of cooling at 95°F. At 5°F that is 800 Btu/h short of the example heating load of 19,000 Btu/h; at 95°F it is 12,900 Btu/h above the example cooling load of 9,500 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 800 sq ft where winters reach 5°F: heating runs from 19,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 9,500 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 215862743 · listed by Mitsubishi Electric · certified Jan 14, 2026 · 2 pairings on 2 certificates share these values

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 2-ton mini-split models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 18,2005.33 kW −4% 1.80
17°Ffull speed 17,2005.04 kW −14% NR
47°Fnormal speed 26,0007.62 kW +4% NR
95°Fcooling, full load 22,4006.56 kW — NR

EER2 11.75 in that test. SEER2 20.0 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
2.96kW
Electrical input in the 95°F cooling test
1.91kW
Seasonal average heating COP
2.78

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 24,000 Btu heat pumps

2-ton mini-split models

This pairing at 5°F
18,200 Btu/h
This unit at 5°F median across its pairings
18,200 Btu/h
Median of 2-ton mini-split models at 5°F
19,000 Btu/h
Models in this group
917

This unit is above 27% of them, at number 668 of 917 by heat at 5°F. The middle half of the group runs 18,000 to 23,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Closest models by heat at 5°F

Every 24,000 Btu (2-ton) unit, ranked by cooling efficiency, then heating efficiency

Certified values for MUZ-HX24NL

2 pairings · 2 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for MUZ-HX24NL
This pairingAll pairings
Heating
Heat output at 47°F normal speed 26,000 Btu/h 26,000 Btu/h
Heat output at 17°F full speed 17,200 Btu/h 17,200 Btu/h
Heat output at 5°F full speed 18,200 Btu/h 18,200 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 70%
COP at 5°F full speed 1.80 1.80
HSPF2 Region IV 9.5 9.5
Cooling
Cooling capacity at 95°F full-load test 22,400 Btu/h 22,400 Btu/h
EER2 at 95°F 11.75 11.75
SEER2 cooling season 20.0 20.0
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Variable speed
Indoor unit MSZ-HX24NL*** 2 indoor units
FurnaceNo furnace None
Cold-climate designation EPA's designation, as published Yes On every pairing
ENERGY STAR Most Efficient EPA's designation, as published Yes On every pairing
Where it is sold US and Canada US and Canada
Model string as certified MUZ-HX24NL***

Pairings, by indoor-unit class

2 indoor units · 2 certified pairings

One row per indoor unit certified with this outdoor unit.

Ductless indoor · 2 indoor units

  1. MSZ-HX24NL*** (the pairing on screen) Mitsubishi Electric 18,200 Btu/hat 5°F, full speed

    1 pairing · 47°F 26,000 Btu/h · 95°F cooling 22,400 Btu/h · Cold output 70% · COP 1.80

  2. MSZ-HX24NL2*** Mitsubishi Electric 18,200 Btu/hat 5°F, full speed

    1 pairing · 47°F 26,000 Btu/h · 95°F cooling 22,400 Btu/h · Cold output 70% · COP 1.80

Indoor units in the ductless indoor class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
MSZ-HX24NL*** (the pairing on screen) Mitsubishi Electric 18,200 26,000 22,400 70% 1.80 Yes 1
MSZ-HX24NL2*** Mitsubishi Electric 18,200 26,000 22,400 70% 1.80 Yes 1

The share is heat output at 5°F divided by the 47°F rating.

Showing 2 of 2 indoor units

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

Variants of the same model number

2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.

1 of 2 shown.

Other model numbers with identical certified values

2 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.

1 of 2 shown.

Product history

  • MUZ-HX24NL first appeared in the certified data between November 2024 and February 2025.

History and definitions

History

First certified record
Most recent certified record
Measurements reported
Jan 14, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “MUZ-HX24NL — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/muz-hx24nl