MWHD024S6-1P

MWHD024S6-1P is in the certified data.

Its certified full-speed heating output at 5°F is 17,300 Btu/h, 72% of its 47°F rating (tests at different compressor speeds) in its certified pairing.

Lennox · mini-split heat pump

All 152 certified Lennox models

MWHD024S6-1P is in the certified data as of Sep 19, 2026.

Certified heating and cooling

Heating at 47°F

24,000

20,400 at 17°F

17,300 at 5°F

Btu/h, certified

1.92 COP at 5°F

Cooling at 95°F

22,000

Btu/h, certified

EER2 12.2 at 95°F

SEER2 20.0

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for MWHD024S6-1P, by outdoor temperature Heating: 17,300 Btu/h at 5°F, 20,400 Btu/h at 17°F, 24,000 Btu/h at 47°F. Cooling: 22,000 Btu/h at 95°F. The bars start at zero. Median of 2-ton mini-split models: 19,000 Btu/h at 5°F, 20,000 Btu/h at 17°F, 25,000 Btu/h at 47°F, 24,000 Btu/h at 95°F. 0 5,000 10,000 15,000 20,000 25,000 Btu/h 17,300 5°F 20,400 17°F 24,000 47°F 22,000 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 2-ton mini-split models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 24,000 Btu/h of heat at 47°F, 20,400 Btu/h at 17°F, and 17,300 Btu/h at 5°F, 72% of its 47°F rating. It delivers 22,000 Btu/h of cooling at 95°F. At 5°F that is 1,700 Btu/h short of the example heating load of 19,000 Btu/h; at 95°F it is 12,500 Btu/h above the example cooling load of 9,500 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 800 sq ft where winters reach 5°F: heating runs from 19,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 9,500 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 215810021 · listed by Lennox · certified Apr 17, 2026 · 1 pairing carries these values

Rebates where you live

Meets the recorded equipment thresholds of 31 programs in 18 states, provinces, or territories:Arizona (1), California (3), Colorado (1), Delaware (1), Idaho (1), Maryland (3), Michigan (2), Mississippi (1), New Jersey (4), Oregon (1), Pennsylvania (4), Texas (2), Manitoba (1), New Brunswick (1), Newfoundland and Labrador (1), Nova Scotia (2), Ontario (1), Yukon (2).

All 31 programs by state and province

Arizona

California

Colorado

Delaware

Idaho

Maryland

Michigan

Mississippi

New Jersey

Oregon

Pennsylvania

Texas

Manitoba

New Brunswick

Newfoundland and Labrador

Nova Scotia

Ontario

Yukon

Threshold comparisons use the unit’s median certified figures across its pairings, not the pairing selected above. Meeting these thresholds means the equipment may qualify; it does not guarantee approval. Service-area, installation, and product-list requirements also apply.

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 2-ton mini-split models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 17,3005.07 kW −9% 1.92
17°Ffull speed 20,4005.98 kW +2% NR
47°Fnormal speed 24,0007.03 kW −4% NR
95°Fcooling, full load 22,0006.45 kW — NR

EER2 12.2 in that test. SEER2 20.0 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
2.64kW
Electrical input in the 95°F cooling test
1.80kW
Seasonal average heating COP
2.34

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 24,000 Btu heat pumps

2-ton mini-split models

This pairing at 5°F
17,300 Btu/h
This unit at 5°F median across its pairings
17,300 Btu/h
Median of 2-ton mini-split models at 5°F
19,000 Btu/h
Models in this group
917

This unit is above 19% of them, at number 740 of 917 by heat at 5°F. The middle half of the group runs 18,000 to 23,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Among 24,000 Btu mini-split models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 643rd of 917 (tied); HSPF2, 920th of 927 (tied). Models without that figure are left out.

Similar ratings at 47°F

These mini-split models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.

  • CU-4Z24BBUC: The same 24,000 Btu/h rating at 47°F; 27,000 Btu/h at 5°F (this model: 17,300).
  • AM3-H24/2DR3B: The same 24,000 Btu/h rating at 47°F; 26,000 Btu/h at 5°F (this model: 17,300).
  • AOU24RLXFZH: The same 24,000 Btu/h rating at 47°F; 25,600 Btu/h at 5°F (this model: 17,300).

Closest models by heat at 5°F

Every 24,000 Btu (2-ton) unit, ranked by cooling efficiency, then heating efficiency

Floor area at the cold test point

The median certified output of 17,300 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.

Floor area by climate band and house condition
Climate bandHouse conditionBtu/h per sq ftApproximate sq ft
MildDrafty, little insulation24–42410–720
MildTypical16–26670–1,080
MildTight, well insulated10–18960–1,730
ColdDrafty, little insulation28–52330–620
ColdTypical18–30580–960
ColdTight, well insulated12–22790–1,440
Very coldDrafty, little insulation32–58300–540
Very coldTypical22–38460–790
Very coldTight, well insulated16–28620–1,080

This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.

Certified values for MWHD024S6-1P

1 pairing · 1 AHRI certificate

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for MWHD024S6-1P
This pairingAll pairings
Heating
Heat output at 47°F normal speed 24,000 Btu/h 24,000 Btu/h
Heat output at 17°F full speed 20,400 Btu/h 20,400 Btu/h
Heat output at 5°F full speed 17,300 Btu/h 17,300 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 72%
COP at 5°F full speed 1.92 1.92
HSPF2 Region IV 8.0 8.0
Cooling
Cooling capacity at 95°F full-load test 22,000 Btu/h 22,000 Btu/h
EER2 at 95°F 12.2 12.2
SEER2 cooling season 20.0 20.0
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-32
Compressor Variable speed
Indoor unit MWHD024S6S-1P 1 indoor unit
FurnaceNo furnace None
Cold-climate designation EPA's designation, as published NC NC
ENERGY STAR Most Efficient EPA's designation, as published Yes On every pairing
Where it is sold United States United States
Model string as certified MWHD024S6-1P

Pairings, by indoor-unit class

1 indoor unit · 1 certified pairing

One row per indoor unit certified with this outdoor unit.

Ductless indoor · 1 indoor unit

  1. MWHD024S6S-1P (the pairing on screen) LENNOX 17,300 Btu/hat 5°F, full speed

    1 pairing · 47°F 24,000 Btu/h · 95°F cooling 22,000 Btu/h · Cold output 72% · COP 1.92

Indoor units in the ductless indoor class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
MWHD024S6S-1P (the pairing on screen) LENNOX 17,300 24,000 22,000 72% 1.92 NC 1

The share is heat output at 5°F divided by the 47°F rating.

Showing 1 of 1 indoor unit

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

Variants of the same model number

3 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.

2 of 3 shown.

Other model numbers with identical certified values

2 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.

1 of 2 shown.

History and definitions

Other WindFree - Standard (RAC) models by nominal cooling size: MWHD009S6-1P (9,000 Btu), MWHD018S6-1P (18,000 Btu).

History

First certified record
Most recent certified record
Measurements reported
Apr 17, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “MWHD024S6-1P — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/mwhd024s6-1p