N5HP5018A1
N5HP5018A1 is in the certified data.
Its certified full-speed heating output at 5°F is 8,900 Btu/h2.61 kW, 52–53% of its 47°F rating, depending on the pairing.
American Standard and Trane · central heat pump
N5HP5018A1 is in the certified data as of Sep 19, 2026.
- 18,000 Btu (1.5-ton)
- Central
- Single stage
- United States
Certified heating and cooling
Heating at 47°F
16,8004.92NR
No 47°F rating for this pairing.
11,5003.37NR at 17°F
8,9002.61NR at 5°F
Btu/hkW, certified
2.11NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 16,800 Btu/h4.92 kW of heat at 47°F, 11,500 Btu/h3.37 kW at 17°F, and 8,900 Btu/h2.61 kW at 5°F, 53% of its 47°F rating. It delivers 18,300 Btu/h5.36 kW of cooling at 95°F. At 5°F that is 2,100 Btu/h0.62 kW short of the example heating load of 11,000 Btu/h3.22 kW; at 95°F it is 12,800 Btu/h3.75 kW above the example cooling load of 5,500 Btu/h1.61 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at one speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 450 sq ft where winters reach 5°F: heating runs from 11,000 Btu/h3.22 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 5,500 Btu/h1.61 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 218469946 · listed by Trane · certified Jun 29, 2026 · 4 pairings share these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Fone compressor speed | 8,9002.61 kW | −21% | 2.11 | |
| 17°Fone compressor speed | 11,5003.37 kW | −9% | NR | |
| 47°Fone compressor speed | 16,8004.92 kW | −7% | NR | |
| 95°Fcooling, full load | 18,3005.36 kW | — | NR |
EER2 12.0 in that test. SEER2 15.2 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 1.24kW
- Electrical input in the 95°F cooling test
- 1.53kW
- Seasonal average heating COP
- 2.34
These exclude backup resistance heat.
How it compares with other 18,000 Btu heat pumps
1.5-ton central models
- This pairing at 5°F
- 8,900 Btu/h2.61 kWNR
- This unit at 5°F median across its pairings
- 8,900 Btu/h2.61 kW
- Median of 1.5-ton central models at 5°F
- 11,200 Btu/h3.28 kW
- Models in this group
- 243
This unit is above 30% of them, at number 171 of 243 by heat at 5°F. The middle half of the group runs 8,600 to 18,000 Btu/h.
Closest models by heat at 5°F
- SP15AZ18AJ2NRussell and Sure · 9,200 Btu/h
- A5HP5018A1Ameristar and RunTru · 9,000 Btu/h
- 5TWR5018A1Trane · 8,900 Btu/h
- YH518E2S11York · 8,900 Btu/h
- YH618E2S11York · 8,900 Btu/h
- 5TWR6018A1Trane · 8,800 Btu/h
Every 18,000 Btu (1.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for N5HP5018A1
8 pairings · 8 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F one speed | 16,800 Btu/h4.92 kWNR | 16,800–17,000 Btu/h4.92–4.98 kW |
| Heat output at 17°F full speed | 11,500 Btu/h3.37 kWNR | 11,500–11,600 Btu/h3.37–3.40 kW |
| Heat output at 5°F full speed | 8,900 Btu/h2.61 kWNR | 8,900 Btu/h2.61 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 53%NR | |
| COP at 5°F full speed | 2.11NR | 2.09–2.11 |
| HSPF2 Region IV | 8.0NR | 8.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 18,300 Btu/h5.36 kWNR | 18,300–18,500 Btu/h5.36–5.42 kW |
| EER2 at 95°F | 12.0NR | 12.0 |
| SEER2 cooling season | 15.2NR | 15.2 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Single stage | |
| Indoor unit | 5PX*B006AS3+TSTAT | 2 indoor units |
| Furnace | A952V060BD3SB | 2 furnaces |
| Cold-climate designation EPA's designation, as published | NC | NC |
| ENERGY STAR Most Efficient EPA's designation, as published | No | On no pairings |
| Where it is sold | United States | United States |
| Model string as certified | N5HP5018A1 | |
Pairings, by indoor-unit class
2 indoor units · 8 certified pairings
One row per indoor unit certified with this outdoor unit.
Furnace paired · 2 indoor units
-
5PX*B006AS3+TSTAT (the pairing on screen) brand not stated 8,900 Btu/h2.61 kWat 5°F, full speed
-
5TXCB006AS3+TSTAT (the pairing on screen) brand not stated 8,900 Btu/h2.61 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · one speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| 5PX*B006AS3+TSTAT (the pairing on screen) | — | 8,9002.61 | 16,9004.95 | 18,4005.39 | 53% | 2.10 | NC | 4 |
| 5TXCB006AS3+TSTAT (the pairing on screen) | — | 8,9002.61 | 16,9004.95 | 18,4005.39 | 53% | 2.10 | NC | 4 |
Sold as, and units with identical certified values
Brands listing this model number
Other brands that list these model numbers
Model number as listed
- N5HP5018A1 8 pairings
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jun 29, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read