Heat Pump List

Tools

NS16H42SA5-**A: every certified pairing

The 42 certified pairings of NS16H42SA5-**A, with the AHRI certificate number, the indoor unit, and the certified figures.

Back to NS16H42SA5-**A

Every certified pairing

Each certified record is an outdoor unit together with a named indoor unit, and a furnace where one is in the pairing. Change the indoor unit and the certified figures change.

Certified pairings of NS16H42SA5-**A
AHRI reference Indoor unit Furnace 5°FBtu/h 17°FBtu/h 47°FBtu/h 95°FBtu/h · cooling COPat 5°F Cold output% of 47°F rating
216497628 NAM42V1TA5*-** — 20,600 25,000 39,500 41,500 2.00 52%
216497629 NAM48V1TA5*-** — 19,600 25,000 39,500 41,000 2.08 50%
216497630 NAM42V2TA5*-** — 20,200 25,200 40,500 41,500 2.14 50%
216497631 NAM48V2TA5*-** — 20,400 25,800 40,500 41,500 2.14 50%
216497634 NCU[C,U]48CT5*-**+TDR NF80U110T5C* 20,400 24,800 39,500 41,500 2.12 52%
216497635 NCU[C,U]48CT5*-**+TDR NF80U090S5C* 20,600 25,000 39,500 41,500 2.12 52%
216497636 NCU[C,U]48CT5*-**+TDR NF80U110S5C* 20,400 25,000 39,500 41,500 2.10 52%
216497637 NCU[C,U]48CT5*-**+TDR NF80L110S5C* 20,400 25,000 39,500 41,500 2.10 52%
216497639 NCU[C,U]48CT5*-**+TDR NF96U110S5C* 20,400 24,800 39,500 41,000 2.10 52%
216497640 NCU[C,U]48CT5*-**+TDR NF97U110V5C* 20,600 25,000 40,000 41,500 2.10 52%
216497641 NCU[C,U]48CT5*-**+TDR NF80X100V5C* 20,600 25,000 40,000 41,500 2.10 52%
216497642 NCU[C,U]48CT5*-**+TDR NF97X080V4C* 20,600 25,000 39,500 41,500 2.10 52%
216497643 NCU[C,U]48CT5*-**+TDR NF97X080V5C* 20,800 25,200 40,000 41,500 2.10 52%
216497645 NCU[C,U]48CT5*-**+TDR NF98U090M4C* 20,600 25,000 39,500 41,000 2.10 52%
216497647 NCU[C,U]48CT5*-**+TDR NF98U110M5C* 20,600 25,000 39,500 41,500 2.10 52%
216497649 NCU[C,U]49CT5*-**+TDR NF95X100S5C* 19,700 25,400 39,500 42,000 2.04 50%
216497650 NCU[C,U]49CT5*-**+TDR NF80U110T5C* 19,400 25,000 39,000 42,000 2.06 50%
216497651 NCU[C,U]49CT5*-**+TDR NF80U090S5C* 19,700 25,200 39,000 42,000 2.08 51%
216497652 NCU[C,U]49CT5*-**+TDR NF80U110S5C* 19,500 25,000 39,000 42,000 2.06 50%
216497653 NCU[C,U]49CT5*-**+TDR NF80L110S5C* 19,500 25,000 39,000 42,000 2.06 50%
216497654 NCU[C,U]49CT5*-**+TDR NF96U090S4C* 20,000 25,400 39,500 42,000 2.06 51%
216497655 NCU[C,U]49CT5*-**+TDR NF96U110S5C* 19,500 25,000 39,000 41,500 2.06 50%
216497656 NCU[C,U]49CT5*-**+TDR NF97U110V5C* 19,600 25,200 39,500 42,000 2.04 50%
216497657 NCU[C,U]49CT5*-**+TDR NF80X100V5C* 19,600 25,200 39,500 42,000 2.04 50%
216497658 NCU[C,U]49CT5*-**+TDR NF97X080V4C* 19,600 25,200 39,000 41,500 2.04 50%
216497659 NCU[C,U]49CT5*-**+TDR NF97X080V5C* 19,900 25,400 39,500 42,000 2.06 50%
216497660 NCU[C,U]49CT5*-**+TDR NF98U090M3C* 19,700 25,200 39,000 41,500 2.04 51%
216497661 NCU[C,U]49CT5*-**+TDR NF98U090M4C* 19,600 25,200 39,000 41,500 2.04 50%
216497662 NCU[C,U]49CT5*-**+TDR NF98U090M5C* 19,800 25,400 39,500 41,500 2.02 50%
216497663 NCU[C,U]49CT5*-**+TDR NF98U110M5C* 19,600 25,200 39,000 41,500 2.04 50%
216497670 NCHC42BT5*-**+TDR NF80U090T4B* 19,500 24,600 39,000 42,000 2.04 50%
216497671 NCHC42BT5*-**+TDR NF80U090S4B* 19,400 24,600 39,000 42,000 2.04 50%
216497672 NCHC42BT5*-**+TDR NF80L090S4B* 19,400 24,600 39,000 42,000 2.04 50%
217052195 NCU[C,U]48CT5*-**+TDR NF80U110V5C* 20,600 25,200 40,000 41,500 2.08 52%
217052196 NCU[C,U]48CT5*-**+TDR NF97U090V3C* 20,600 25,000 39,500 41,000 2.08 52%
217052198 NCU[C,U]49CT5*-**+TDR NF80U110V5C* 19,700 25,200 39,500 41,500 2.04 50%
217052199 NCU[C,U]49CT5*-**+TDR NF97U090V3C* 19,600 25,200 39,000 41,500 2.04 50%
217052200 NCU[C,U]49CT5*-**+TDR NF97U090V5C* 20,000 25,400 39,500 42,000 2.06 51%
218159786 NCU[C,U]48CT5*-**+TDR NF97U090T4C* 20,800 25,200 40,000 41,500 2.10 52%
218159787 NCU[C,U]49CT5*-**+TDR NF97U090T4C* 19,900 25,400 39,500 42,000 2.06 50%
218159788 NCU[C,U]48CT5*-**+TDR NF97U110T5C* 20,600 25,200 40,000 41,500 2.08 52%
218159789 NCU[C,U]49CT5*-**+TDR NF97U110T5C* 19,900 25,400 39,500 42,000 2.06 50%

The share is heat output at 5°F divided by the 47°F rating.

42 of 42 certified pairings