OARX-H09A-O is in the certified data.

Its certified full-speed heating output at 5°F is 8,500–11,500 Btu/h, 81–108% of its 47°F rating (tests at different compressor speeds), depending on the pairing.

Ouellet · mini-split heat pump

OARX-H09A-O is in the certified data as of Sep 19, 2026. OARX-H09A-O changed its certified heat output at 17°F on AHRI certificate 216472855 from 8,900 Btu/h to 12,000 Btu/h in the certified data between August 2025 and September 2026.

3 certified pairings with 3 different figures. See all

Certified heating and cooling

Heating at 47°F

10,500

8,900 at 17°F

9,200 at 5°F

Btu/h, certified

1.80 COP at 5°F

Cooling at 95°F

9,100

Btu/h, certified

EER2 14.3 at 95°F

SEER2 22.3

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for OARX-H09A-O, by outdoor temperature Heating: 9,200 Btu/h at 5°F, 8,900 Btu/h at 17°F, 10,500 Btu/h at 47°F. Cooling: 9,100 Btu/h at 95°F. The bars start at zero. Median of 9,000 Btu mini-split models: 7,700 Btu/h at 5°F, 8,000 Btu/h at 17°F, 10,000 Btu/h at 47°F, 9,000 Btu/h at 95°F. 0 2,500 5,000 7,500 10,000 12,500 Btu/h 9,200 5°F 8,900 17°F 10,500 47°F 9,100 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 9,000 Btu mini-split models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 10,500 Btu/h of heat at 47°F, 8,900 Btu/h at 17°F, and 9,200 Btu/h at 5°F, 88% of its 47°F rating. It delivers 9,100 Btu/h of cooling at 95°F. At 5°F that is 1,700 Btu/h above the example heating load of 7,500 Btu/h; at 95°F it is 5,600 Btu/h above the example cooling load of 3,500 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 9,000 Btu mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 300 sq ft where winters reach 5°F: heating runs from 7,500 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 3,500 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 217037914 · listed by Ouellet · certified Sep 22, 2026 · 1 pairing carries these values

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 9,000 Btu mini-split models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 9,2002.70 kW +19% 1.80
17°Ffull speed 8,9002.61 kW +11% NR
47°Fnormal speed 10,5003.08 kW +5% NR
95°Fcooling, full load 9,1002.67 kW — NR

EER2 14.3 in that test. SEER2 22.3 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
1.50kW
Electrical input in the 95°F cooling test
0.64kW
Seasonal average heating COP
2.78

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 9,000 Btu heat pumps

9,000 Btu mini-split models

This pairing at 5°F
9,200 Btu/h
This unit at 5°F median across its pairings
9,200 Btu/h
Median of 9,000 Btu mini-split models at 5°F
7,700 Btu/h
Models in this group
894

This unit is above 70% of them, at number 264 of 894 by heat at 5°F. The middle half of the group runs 7,000 to 9,500 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Closest models by heat at 5°F

Every 9,000 Btu unit, ranked by cooling efficiency, then heating efficiency

Certified values for OARX-H09A-O

3 pairings · 3 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for OARX-H09A-O
This pairingAll pairings
Heating
Heat output at 47°F normal speed 10,500 Btu/h 10,500–10,600 Btu/h
Heat output at 17°F full speed 8,900 Btu/h 8,900–12,000 Btu/h
Heat output at 5°F full speed 9,200 Btu/h 8,500–11,500 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 88%
COP at 5°F full speed 1.80 1.80–2.11
HSPF2 Region IV 9.5 9.5–11.2
Cooling
Cooling capacity at 95°F full-load test 9,100 Btu/h 9,100 Btu/h
EER2 at 95°F 14.3 14.3–16.8
SEER2 cooling season 22.3 22.3–30.0
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-32
Compressor Variable speed
Indoor unit OFCX1-H09A-I 3 indoor units
FurnaceNo furnace None
Cold-climate designation EPA's designation, as published Yes On every pairing
ENERGY STAR Most Efficient EPA's designation, as published Yes On every pairing
Where it is sold US and Canada US and Canada
Model string as certified OARX-H09A-O

Pairings, by indoor-unit class

3 indoor units · 3 certified pairings

One row per indoor unit certified with this outdoor unit.

Ductless indoor · 3 indoor units

  1. OARX-H09A-I OUELLET 11,500 Btu/hat 5°F, full speed

    1 pairing · 47°F 10,600 Btu/h · 95°F cooling 9,100 Btu/h · Cold output 108% · COP 2.11

  2. OFCX1-H09A-I (the pairing on screen) OUELLET 9,200 Btu/hat 5°F, full speed

    1 pairing · 47°F 10,500 Btu/h · 95°F cooling 9,100 Btu/h · Cold output 88% · COP 1.80

  3. OICX1-H09A-I OUELLET 8,500 Btu/hat 5°F, full speed

    1 pairing · 47°F 10,500 Btu/h · 95°F cooling 9,100 Btu/h · Cold output 81% · COP 1.84

Indoor units in the ductless indoor class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
OARX-H09A-I OUELLET 11,500 10,600 9,100 108% 2.11 Yes 1
OFCX1-H09A-I (the pairing on screen) OUELLET 9,200 10,500 9,100 88% 1.80 Yes 1
OICX1-H09A-I OUELLET 8,500 10,500 9,100 81% 1.84 Yes 1

The share is heat output at 5°F divided by the 47°F rating.

Showing 3 of 3 indoor units

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

Product history

  • OARX-H09A-O changed its certified heat output at 17°F on AHRI certificate 216472855 from 8,900 Btu/h to 12,000 Btu/h in the certified data between August 2025 and September 2026.
  • OARX-H09A-O changed its certified heat output at 17°F on AHRI certificate 216472855 from 6,700 Btu/h to 8,900 Btu/h in the certified data between March 2025 and May 2025.
  • OARX-H09A-O first appeared in the certified data between November 2024 and February 2025.

History and definitions

History

First certified record
Most recent certified record
Measurements reported
Sep 22, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read