PAS-24BUFASDQ1-LAC
PAS-24BUFASDQ1-LAC is in the certified data.
Its certified full-speed heating output at 5°F is 18,000–19,400 Btu/h5.28–5.69 kW, 82–88% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
Hitachi · mini-split heat pump
PAS-24BUFASDQ1-LAC is in the certified data as of Sep 19, 2026.
- 24,000 Btu (2-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
22,0006.45NR
No 47°F rating for this pairing.
20,0005.86NR at 17°F
19,0005.57NR at 5°F
Btu/hkW, certified
2.50NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 22,000 Btu/h6.45 kW of heat at 47°F, 20,000 Btu/h5.86 kW at 17°F, and 19,000 Btu/h5.57 kW at 5°F, 86% of its 47°F rating. It delivers 22,000 Btu/h6.45 kW of cooling at 95°F. At 5°F that matches the example heating load of 19,000 Btu/h5.57 kW; at 95°F it is 12,500 Btu/h3.66 kW above the example cooling load of 9,500 Btu/h2.78 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 800 sq ft where winters reach 5°F: heating runs from 19,000 Btu/h5.57 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 9,500 Btu/h2.78 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 217450770 · listed by Hitachi · certified Mar 26, 2026 · 1 pairing carries these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 19,0005.57 kW | 0% | 2.50 | |
| 17°Ffull speed | 20,0005.86 kW | 0% | NR | |
| 47°Fnormal speed | 22,0006.45 kW | −12% | NR | |
| 95°Fcooling, full load | 22,0006.45 kW | — | NR |
EER2 13.0 in that test. SEER2 21.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 2.23kW
- Electrical input in the 95°F cooling test
- 1.69kW
- Seasonal average heating COP
- 2.93
These exclude backup resistance heat.
How it compares with other 24,000 Btu heat pumps
2-ton mini-split models
- This pairing at 5°F
- 19,000 Btu/h5.57 kWNR
- This unit at 5°F median across its pairings
- 19,000 Btu/h5.57 kW
- Median of 2-ton mini-split models at 5°F
- 19,000 Btu/h5.57 kW
- Models in this group
- 917
This unit is above 48% of them, at number 481 of 917 by heat at 5°F. The middle half of the group runs 18,000 to 23,000 Btu/h.
Closest models by heat at 5°F
- FPHFR24A3AFriedrich · 19,000 Btu/h
- GS24HP230V1PUOGree · 19,000 Btu/h
- MO4EX-H27B-2BMidea · 19,000 Btu/h
- QVBO*24R32OQuébecVair · 19,000 Btu/h
- SAK-24-DT2/220VStar Air Kontrol · 19,000 Btu/h
- TWH24PD32AOTosot · 19,000 Btu/h
Every 24,000 Btu (2-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for PAS-24BUFASDQ1-LAC
4 pairings · 4 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 22,000 Btu/h6.45 kWNR | 22,000 Btu/h6.45 kW |
| Heat output at 17°F full speed | 20,000 Btu/h5.86 kWNR | 20,000–23,000 Btu/h5.86–6.74 kW |
| Heat output at 5°F full speed | 19,000 Btu/h5.57 kWNR | 18,000–19,400 Btu/h5.28–5.69 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 86%NR | |
| COP at 5°F full speed | 2.50NR | 2.00–2.50 |
| HSPF2 Region IV | 10.0NR | 9.1–10.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 22,000 Btu/h6.45 kWNR | 22,000 Btu/h6.45 kW |
| EER2 at 95°F | 13.0NR | 12.7–13.0 |
| SEER2 cooling season | 21.0NR | 20.0–24.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-32 | |
| Compressor | Variable speed | |
| Indoor unit | PPFC-B24UFA1DQ | 4 indoor units |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | PAS-24BUFASDQ1-LAC | |
Pairings, by indoor-unit class
4 indoor units · 4 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 4 indoor units
-
PCI-B24UFA1DQ (the pairing on screen) HITACHI 19,000 Btu/h5.57 kWat 5°F, full speed
-
PPFC-B24UFA1DQ (the pairing on screen) HITACHI 19,000 Btu/h5.57 kWat 5°F, full speed
-
PPIM-B24UFA1DQ (the pairing on screen) HITACHI 19,400 Btu/h5.69 kWat 5°F, full speed
-
PPK-B24UFA1DQ (the pairing on screen) HITACHI 18,000 Btu/h5.28 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| PCI-B24UFA1DQ (the pairing on screen) | HITACHI | 19,0005.57 | 22,0006.45 | 22,0006.45 | 86% | 2.50 | Yes | 1 |
| PPFC-B24UFA1DQ (the pairing on screen) | HITACHI | 19,0005.57 | 22,0006.45 | 22,0006.45 | 86% | 2.50 | Yes | 1 |
| PPIM-B24UFA1DQ (the pairing on screen) | HITACHI | 19,4005.69 | 22,0006.45 | 22,0006.45 | 88% | 2.10 | Yes | 1 |
| PPK-B24UFA1DQ (the pairing on screen) | HITACHI | 18,0005.28 | 22,0006.45 | 22,0006.45 | 82% | 2.00 | Yes | 1 |
Sold as, and units with identical certified values
Brands listing this model number
Model number as listed
- PAS-24BUFASDQ1-LAC 4 pairings
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- PAS-24BUFASDQ1-LAC first appeared in the certified data between May 2025 and June 2025.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Mar 26, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read