RD16AY48AJVC

RD16AY48AJVC is in the certified data.

Its certified full-speed heating output at 5°F is 22,000–25,800 Btu/h, 55–60% of its 47°F rating (tests at different compressor speeds), depending on the pairing.

Friedrich, Rheem + 3 more · central heat pump

RD16AY48AJVC is in the certified data as of Sep 19, 2026.

35 certified pairings with 3 different figures. See all

Certified heating and cooling

Heating at 47°F

40,000

29,600 at 17°F

22,000 at 5°F

Btu/h, certified

1.90 COP at 5°F

Cooling at 95°F

40,000

Btu/h, certified

EER2 9.0 at 95°F

SEER2 16.0

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for RD16AY48AJVC, by outdoor temperature Heating: 22,000 Btu/h at 5°F, 29,600 Btu/h at 17°F, 40,000 Btu/h at 47°F. Cooling: 40,000 Btu/h at 95°F. The bars start at zero. Median of 3.5-ton central models: 33,000 Btu/h at 5°F, 31,000 Btu/h at 17°F, 44,000 Btu/h at 47°F, 44,000 Btu/h at 95°F. 0 10,000 20,000 30,000 40,000 50,000 Btu/h 22,000 5°F 29,600 17°F 40,000 47°F 40,000 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 3.5-ton central models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 40,000 Btu/h of heat at 47°F, 29,600 Btu/h at 17°F, and 22,000 Btu/h at 5°F, 55% of its 47°F rating. It delivers 40,000 Btu/h of cooling at 95°F. At 5°F that is 11,000 Btu/h short of the example heating load of 33,000 Btu/h; at 95°F it is 23,000 Btu/h above the example cooling load of 17,000 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 3.5-ton central models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 1,400 sq ft where winters reach 5°F: heating runs from 33,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 17,000 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 218719599 · listed by Friedrich · certified Sep 15, 2026 · 18 pairings share these values

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 3.5-ton central models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 22,0006.45 kW −33% 1.90
17°Ffull speed 29,6008.67 kW −5% NR
47°Fnormal speed 40,00011.72 kW −9% NR
95°Fcooling, full load 40,00011.72 kW — NR

EER2 9.0 in that test. SEER2 16.0 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
3.39kW
Electrical input in the 95°F cooling test
4.44kW
Seasonal average heating COP
2.49

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 42,000 Btu heat pumps

3.5-ton central models

This pairing at 5°F
22,000 Btu/h
This unit at 5°F median across its pairings
22,000 Btu/h
Median of 3.5-ton central models at 5°F
33,000 Btu/h
Models in this group
222

This unit is above 40% of them, at number 134 of 222 by heat at 5°F. The middle half of the group runs 20,000 to 40,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Closest models by heat at 5°F

Every 42,000 Btu (3.5-ton) unit, ranked by cooling efficiency, then heating efficiency

Certified values for RD16AY48AJVC

35 pairings · 35 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for RD16AY48AJVC
This pairingAll pairings
Heating
Heat output at 47°F normal speed 40,000 Btu/h 40,000–43,000 Btu/h
Heat output at 17°F full speed 29,600 Btu/h 29,200–30,400 Btu/h
Heat output at 5°F full speed 22,000 Btu/h 22,000–25,800 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 55%
COP at 5°F full speed 1.90 1.90–2.00
HSPF2 Region IV 8.5 8.1–8.5
Cooling
Cooling capacity at 95°F full-load test 40,000 Btu/h 40,000–43,000 Btu/h
EER2 at 95°F 9.0 9.0–10.0
SEER2 cooling season 16.0 16.0
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Variable speed
Indoor unit RCFY4821STAAM 9 indoor units
FurnaceFR972V0705A21UPS 9 furnaces
Cold-climate designation EPA's designation, as published Yes On some pairings
ENERGY STAR Most Efficient EPA's designation, as published No On no pairings
Where it is sold US and Canada US and Canada
Model string as certified RD16AY48AJVC

Pairings, by indoor-unit class

9 indoor units · 35 certified pairings

One row per indoor unit certified with this outdoor unit.

Furnace paired · 6 indoor units

  1. RCFY4821STAAM (the pairing on screen) brand not stated 22,000 Btu/hat 5°F, full speed

    9 pairings, 6 with a furnace · 47°F 40,000 Btu/h · 95°F cooling 40,000 Btu/h · Cold output 55% · COP 1.90

  2. TCFY4821STAAM brand not stated 22,000 Btu/hat 5°F, full speed

    9 pairings, 9 with a furnace · 47°F 40,000 Btu/h · 95°F cooling 40,000 Btu/h · Cold output 55% · COP 1.90

  3. RCFY4821STANM brand not stated 25,800 Btu/hat 5°F, full speed

    3 pairings, 2 with a furnace · 47°F 43,000 Btu/h · 95°F cooling 43,000 Btu/h · Cold output 60% · COP 2.00

  4. RCFY4824STANM brand not stated 25,800 Btu/hat 5°F, full speed

    3 pairings, 2 with a furnace · 47°F 43,000 Btu/h · 95°F cooling 43,000 Btu/h · Cold output 60% · COP 2.00

  5. TCFY4821STANM brand not stated 25,800 Btu/hat 5°F, full speed

    3 pairings, 2 with a furnace · 47°F 43,000 Btu/h · 95°F cooling 43,000 Btu/h · Cold output 60% · COP 2.00

  6. TCFY4824STANM brand not stated 25,800 Btu/hat 5°F, full speed

    3 pairings, 2 with a furnace · 47°F 43,000 Btu/h · 95°F cooling 43,000 Btu/h · Cold output 60% · COP 2.00

Indoor units in the furnace paired class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
RCFY4821STAAM (the pairing on screen) — 22,000 40,000 40,000 55% 1.90 Yes 9
TCFY4821STAAM — 22,000 40,000 40,000 55% 1.90 Yes 9
RCFY4821STANM — 25,800 43,000 43,000 60% 2.00 Yes 3
RCFY4824STANM — 25,800 43,000 43,000 60% 2.00 Yes 3
TCFY4821STANM — 25,800 43,000 43,000 60% 2.00 Yes 3
TCFY4824STANM — 25,800 43,000 43,000 60% 2.00 Yes 3

Air handler · 3 indoor units

  1. RHMVY4821SEACA brand not stated 24,400 Btu/hat 5°F, full speed

    2 pairings · 47°F 40,500 Btu/h · 95°F cooling 40,500 Btu/h · Cold output 60% · COP 2.00

  2. SHMVY4821SEACA brand not stated 24,400 Btu/hat 5°F, full speed

    2 pairings · 47°F 40,500 Btu/h · 95°F cooling 40,500 Btu/h · Cold output 60% · COP 2.00

  3. FRHMVY4821SEACA brand not stated 24,400 Btu/hat 5°F, full speed

    1 pairing · 47°F 40,500 Btu/h · 95°F cooling 40,500 Btu/h · Cold output 60% · COP 2.00

Indoor units in the air handler class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
RHMVY4821SEACA — 24,400 40,500 40,500 60% 2.00 NC 2
SHMVY4821SEACA — 24,400 40,500 40,500 60% 2.00 NC 2
FRHMVY4821SEACA — 24,400 40,500 40,500 60% 2.00 NC 1

The share is heat output at 5°F divided by the 47°F rating.

Showing 9 of 9 indoor units

Sold as, and units with identical certified values

History and definitions

History

First certified record
Most recent certified record
Measurements reported
Sep 15, 2026
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “RD16AY48AJVC — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/rd16ay48ajvc