RXTH24AVJU
Daikin · mini-split heat pump
All 89 certified Daikin models
RXTH24AVJU is in the certified data as of Sep 19, 2026.
- 24,000 Btu (2-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
24,0007.03NR
No 47°F rating for this pairing.
16,8004.92NR at 17°F
24,0007.03NR at 5°F
Btu/hkW, certified
1.80NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 24,000 Btu/h7.03 kW of heat at 47°F, 16,800 Btu/h4.92 kW at 17°F, and 24,000 Btu/h7.03 kW at 5°F, 100% of its 47°F rating. It delivers 22,400 Btu/h6.56 kW of cooling at 95°F. At 5°F that is 5,000 Btu/h1.47 kW above the example heating load of 19,000 Btu/h5.57 kW; at 95°F it is 12,900 Btu/h3.78 kW above the example cooling load of 9,500 Btu/h2.78 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 800 sq ft where winters reach 5°F: heating runs from 19,000 Btu/h5.57 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 9,500 Btu/h2.78 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 218713987 · listed by Daikin · certified Aug 20, 2026 · 1 pairing carries these values
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 24,0007.03 kW | +26% | 1.80 | |
| 17°Ffull speed | 16,8004.92 kW | −16% | NR | |
| 47°Fnormal speed | 24,0007.03 kW | −4% | NR | |
| 95°Fcooling, full load | 22,4006.56 kW | — | NR |
EER2 12.0 in that test. SEER2 21.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 3.91kW
- Electrical input in the 95°F cooling test
- 1.87kW
- Seasonal average heating COP
- 2.78
These exclude backup resistance heat.
How it compares with other 24,000 Btu heat pumps
2-ton mini-split models
- This pairing at 5°F
- 24,000 Btu/h7.03 kWNR
- This unit at 5°F median across its pairings
- 24,000 Btu/h7.03 kW
- Median of 2-ton mini-split models at 5°F
- 19,000 Btu/h5.57 kW
- Models in this group
- 917
This unit is above 76% of them, at number 216 of 917 by heat at 5°F. The middle half of the group runs 18,000 to 23,000 Btu/h.
Among 24,000 Btu mini-split models, each by its median certified pairing, highest first: 5°F output as a share of its 47°F rating, 31st of 917 (tied); HSPF2, 465th of 927 (tied). Models without that figure are left out.
Similar ratings at 47°F
These mini-split models share the nominal cooling size. Comparisons use each model’s median certified figures across pairings.
- H24SVH20XQC: The same 24,000 Btu/h rating at 47°F; 13,100 Btu/h at 5°F (this model: 24,000).
- PIAW2421080AB: The same 24,000 Btu/h rating at 47°F; 15,300 Btu/h at 5°F (this model: 24,000).
- SU-COSMO24-230/O: The same 24,000 Btu/h rating at 47°F; 15,700 Btu/h at 5°F (this model: 24,000).
Closest models by heat at 5°F
- O-HH-24-HP-C-230C-OMRCOOL · 24,000 Btu/h
- QOS24H2BH0AInnovair · 24,000 Btu/h
- RXP24AVJUDaikin · 24,000 Btu/h
- SAP24HP230V1R32AOGree · 24,000 Btu/h
- SHC24AH2AGSlimAir · 24,000 Btu/h
- TWH24AR32AOTosot · 24,000 Btu/h
Every 24,000 Btu (2-ton) unit, ranked by cooling efficiency, then heating efficiency
Floor area at the cold test point
The median certified output of 24,000 Btu/h at 5°F matches the size calculator’s heating estimate for these floor areas, rounded to about 10 sq ft. Each range divides that output by the climate band’s heating rates.
| Climate band | House condition | Btu/h per sq ft | Approximate sq ft |
|---|---|---|---|
| Mild | Drafty, little insulation | 24–42 | 570–1,000 |
| Mild | Typical | 16–26 | 920–1,500 |
| Mild | Tight, well insulated | 10–18 | 1,330–2,400 |
| Cold | Drafty, little insulation | 28–52 | 460–860 |
| Cold | Typical | 18–30 | 800–1,330 |
| Cold | Tight, well insulated | 12–22 | 1,090–2,000 |
| Very cold | Drafty, little insulation | 32–58 | 410–750 |
| Very cold | Typical | 22–38 | 630–1,090 |
| Very cold | Tight, well insulated | 16–28 | 860–1,500 |
This is an estimate, not a house-specific load calculation. Output stays at the 5°F test point for every band; it does not predict output at the band’s winter design temperature.
Certified values for RXTH24AVJU
1 pairing · 1 AHRI certificate
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 24,000 Btu/h7.03 kWNR | 24,000 Btu/h7.03 kW |
| Heat output at 17°F full speed | 16,800 Btu/h4.92 kWNR | 16,800 Btu/h4.92 kW |
| Heat output at 5°F full speed | 24,000 Btu/h7.03 kWNR | 24,000 Btu/h7.03 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 100%NR | |
| COP at 5°F full speed | 1.80NR | 1.80 |
| HSPF2 Region IV | 9.5NR | 9.5 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 22,400 Btu/h6.56 kWNR | 22,400 Btu/h6.56 kW |
| EER2 at 95°F | 12.0NR | 12.0 |
| SEER2 cooling season | 21.0NR | 21.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-32 | |
| Compressor | Variable speed | |
| Indoor unit | FTXV24AVJU* | 1 indoor unit |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | RXTH24AVJU* | |
Pairings, by indoor-unit class
1 indoor unit · 1 certified pairing
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 1 indoor unit
-
FTXV24AVJU* (the pairing on screen) DAIKIN 24,000 Btu/h7.03 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| FTXV24AVJU* (the pairing on screen) | DAIKIN | 24,0007.03 | 24,0007.03 | 22,4006.56 | 100% | 1.80 | Yes | 1 |
Sold as, and units with identical certified values
Variants of the same model number
2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
Other model numbers with identical certified values
2 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
Other AURORA models by nominal cooling size: RXT09AVJU (9,000 Btu), RXT12AVJU (12,000 Btu), RXTH12AVJU (12,000 Btu), RXP15AVJU (15,000 Btu), RXT15AVJU (15,000 Btu), RXTH15AVJU (15,000 Btu), RXP18AVJU (18,000 Btu), RXT18AVJU (18,000 Btu); more models from this brand.
History
- First certified record
- Most recent certified record
- Measurements reported
- Aug 20, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read