Heat Pump List

Tools

SUZ-AA30NL

SUZ-AA30NL is in the certified data.

Its certified full-speed heating output at 5°F is 16,700–17,000 Btu/h, 56–57% of its 47°F rating (tests at different compressor speeds), depending on the pairing.

Mitsubishi Electric · mini-split heat pump

SUZ-AA30NL is in the certified data as of Sep 19, 2026.

2 certified pairings with 2 different figures. See all

Certified heating and cooling

Heating at 47°F

30,000

18,600 at 17°F

16,700 at 5°F

Btu/h, certified

2.50 COP at 5°F

Cooling at 95°F

27,000

Btu/h, certified

EER2 11.2 at 95°F

SEER2 17.8

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for SUZ-AA30NL, by outdoor temperature Heating: 16,700 Btu/h at 5°F, 18,600 Btu/h at 17°F, 30,000 Btu/h at 47°F. Cooling: 27,000 Btu/h at 95°F. The bars start at zero. Median of 2-ton mini-split models: 19,000 Btu/h at 5°F, 20,000 Btu/h at 17°F, 25,000 Btu/h at 47°F, 24,000 Btu/h at 95°F. 0 10,000 20,000 30,000 Btu/h 16,700 5°F 18,600 17°F 30,000 47°F 27,000 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 2-ton mini-split models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 30,000 Btu/h of heat at 47°F, 18,600 Btu/h at 17°F, and 16,700 Btu/h at 5°F, 56% of its 47°F rating. It delivers 27,000 Btu/h of cooling at 95°F. At 5°F that is 2,300 Btu/h short of the example heating load of 19,000 Btu/h; at 95°F it is 17,500 Btu/h above the example cooling load of 9,500 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 800 sq ft where winters reach 5°F: heating runs from 19,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 9,500 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 215748461 · listed by Mitsubishi Electric · certified Jul 29, 2025 · 1 pairing carries these values

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 2-ton mini-split models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 16,7004.89 kW −12% 2.50
17°Ffull speed 18,6005.45 kW −7% NR
47°Fnormal speed 30,0008.79 kW +20% NR
95°Fcooling, full load 27,0007.91 kW — NR

EER2 11.2 in that test. SEER2 17.8 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
1.96kW
Electrical input in the 95°F cooling test
2.41kW
Seasonal average heating COP
2.64

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 24,000 Btu heat pumps

2-ton mini-split models

This pairing at 5°F
16,700 Btu/h
This unit at 5°F median across its pairings
16,700 Btu/h
Median of 2-ton mini-split models at 5°F
19,000 Btu/h
Models in this group
917

This unit is above 11% of them, at number 815 of 917 by heat at 5°F. The middle half of the group runs 18,000 to 23,000 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Closest models by heat at 5°F

Every 24,000 Btu (2-ton) unit, ranked by cooling efficiency, then heating efficiency

Certified values for SUZ-AA30NL

2 pairings · 2 AHRI certificates

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for SUZ-AA30NL
This pairingAll pairings
Heating
Heat output at 47°F normal speed 30,000 Btu/h 30,000 Btu/h
Heat output at 17°F full speed 18,600 Btu/h 18,600–18,700 Btu/h
Heat output at 5°F full speed 16,700 Btu/h 16,700–17,000 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 56%
COP at 5°F full speed 2.50 2.50–3.00
HSPF2 Region IV 9.0 9.0–9.5
Cooling
Cooling capacity at 95°F full-load test 27,000 Btu/h 27,000 Btu/h
EER2 at 95°F 11.2 11.2–11.7
SEER2 cooling season 17.8 17.8–20.3
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Variable speed
Indoor unit SVZ-AP30NL*** 2 indoor units
FurnaceNo furnace None
Cold-climate designation EPA's designation, as published NC NC
ENERGY STAR Most Efficient EPA's designation, as published Yes On every pairing
Where it is sold United States United States
Model string as certified SUZ-AA30NL***

Pairings, by indoor-unit class

2 indoor units · 2 certified pairings

One row per indoor unit certified with this outdoor unit.

Ductless indoor · 2 indoor units

  1. PEAD-AA30NL*** Mitsubishi Electric 17,000 Btu/hat 5°F, full speed

    1 pairing · 47°F 30,000 Btu/h · 95°F cooling 27,000 Btu/h · Cold output 57% · COP 3.00

  2. SVZ-AP30NL*** (the pairing on screen) Mitsubishi Electric 16,700 Btu/hat 5°F, full speed

    1 pairing · 47°F 30,000 Btu/h · 95°F cooling 27,000 Btu/h · Cold output 56% · COP 2.50

Indoor units in the ductless indoor class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
PEAD-AA30NL*** Mitsubishi Electric 17,000 30,000 27,000 57% 3.00 NC 1
SVZ-AP30NL*** (the pairing on screen) Mitsubishi Electric 16,700 30,000 27,000 56% 2.50 NC 1

The share is heat output at 5°F divided by the 47°F rating.

Showing 2 of 2 indoor units

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

Product history

  • SUZ-AA30NL first appeared in the certified data between March 2025 and May 2025.

History and definitions

History

First certified record
Most recent certified record
Measurements reported
Jul 29, 2025
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “SUZ-AA30NL — certified heat output”. Certified figures dated , checked daily.