SUZ-AK36NLHZ
Mitsubishi Electric · mini-split heat pump
SUZ-AK36NLHZ is in the certified data as of Sep 19, 2026.
- 30,000 Btu (2.5-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
42,00012.31NR
No 47°F rating for this pairing.
31,2009.14NR at 17°F
38,00011.14NR at 5°F
Btu/hkW, certified
1.90NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 42,000 Btu/h12.31 kW of heat at 47°F, 31,200 Btu/h9.14 kW at 17°F, and 38,000 Btu/h11.14 kW at 5°F, 90% of its 47°F rating. It delivers 32,000 Btu/h9.38 kW of cooling at 95°F. At 5°F that is 13,000 Btu/h3.81 kW above the example heating load of 25,000 Btu/h7.33 kW; at 95°F it is 19,500 Btu/h5.71 kW above the example cooling load of 12,500 Btu/h3.66 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 2.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 1,050 sq ft where winters reach 5°F: heating runs from 25,000 Btu/h7.33 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 12,500 Btu/h3.66 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 218451125 · listed by Mitsubishi Electric · certified May 28, 2026 · 2 pairings share these values
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 38,00011.14 kW | +52% | 1.90 | |
| 17°Ffull speed | 31,2009.14 kW | +22% | NR | |
| 47°Fnormal speed | 42,00012.31 kW | +40% | NR | |
| 95°Fcooling, full load | 32,0009.38 kW | — | NR |
EER2 11.7 in that test. SEER2 17.2 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 5.86kW
- Electrical input in the 95°F cooling test
- 2.74kW
- Seasonal average heating COP
- 2.61
These exclude backup resistance heat.
How it compares with other 30,000 Btu heat pumps
2.5-ton mini-split models
- This pairing at 5°F
- 38,000 Btu/h11.14 kWNR
- This unit at 5°F median across its pairings
- 38,000 Btu/h11.14 kW
- Median of 2.5-ton mini-split models at 5°F
- 25,000 Btu/h7.33 kW
- Models in this group
- 405
This unit is above 99% of them, at number 5 of 405 by heat at 5°F. The middle half of the group runs 20,000 to 27,000 Btu/h.
Closest models by heat at 5°F
- SUZ-KA36NAHZMitsubishi Electric · 38,000 Btu/h
- 37MGHAQ30EA3Bryant, Carrier + 3 more · 36,000 Btu/h
- AMW4-36U3STAHisense · 36,000 Btu/h
- AR36DXFUMGMXSamsung · 36,000 Btu/h
- AZ-36M422SCOAzur · 36,000 Btu/h
- CA4-36UMTOComfiAire · 36,000 Btu/h
Every 30,000 Btu (2.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for SUZ-AK36NLHZ
4 pairings · 4 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 42,000 Btu/h12.31 kWNR | 40,000–42,000 Btu/h11.72–12.31 kW |
| Heat output at 17°F full speed | 31,200 Btu/h9.14 kWNR | 24,400–31,200 Btu/h7.15–9.14 kW |
| Heat output at 5°F full speed | 38,000 Btu/h11.14 kWNR | 37,000–38,000 Btu/h10.84–11.14 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 90%NR | |
| COP at 5°F full speed | 1.90NR | 1.80–1.90 |
| HSPF2 Region IV | 8.9NR | 8.5–9.1 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 32,000 Btu/h9.38 kWNR | 32,000–36,000 Btu/h9.38–10.55 kW |
| EER2 at 95°F | 11.7NR | 10.5–12.3 |
| SEER2 cooling season | 17.2NR | 15.2–19.5 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-454B | |
| Compressor | Variable speed | |
| Indoor unit | PAA-BA36NL*** | 4 indoor units |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On some pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | SUZ-AK36NLHZ*** | |
Pairings, by indoor-unit class
4 indoor units · 4 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 4 indoor units
-
PAA-BA36NL*** (the pairing on screen) Mitsubishi Electric 38,000 Btu/h11.14 kWat 5°F, full speed
-
PAA-CA36NL*** (the pairing on screen) Mitsubishi Electric 38,000 Btu/h11.14 kWat 5°F, full speed
-
PEAD-AA36NL*** (the pairing on screen) Mitsubishi Electric 38,000 Btu/h11.14 kWat 5°F, full speed
-
SVZ-AP36NL*** (the pairing on screen) Mitsubishi Electric 37,000 Btu/h10.84 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| PAA-BA36NL*** (the pairing on screen) | Mitsubishi Electric | 38,00011.14 | 42,00012.31 | 32,0009.38 | 90% | 1.90 | Yes | 1 |
| PAA-CA36NL*** (the pairing on screen) | Mitsubishi Electric | 38,00011.14 | 42,00012.31 | 32,0009.38 | 90% | 1.90 | Yes | 1 |
| PEAD-AA36NL*** (the pairing on screen) | Mitsubishi Electric | 38,00011.14 | 40,00011.72 | 36,00010.55 | 95% | 1.80 | Yes | 1 |
| SVZ-AP36NL*** (the pairing on screen) | Mitsubishi Electric | 37,00010.84 | 40,00011.72 | 36,00010.55 | 93% | 1.80 | Yes | 1 |
Sold as, and units with identical certified values
Brands listing this model number
Model number as listed
- SUZ-AK36NLHZ*** 4 pairings
Variants of the same model number
2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.
1 of 2 shown.
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- SUZ-AK36NLHZ first appeared in the certified data between September 2024 and November 2024.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- May 28, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read