SUZ-AK48NLHZ is in the certified data.

Its certified full-speed heating output at 5°F is 52,000 Btu/h, 87% of its 47°F rating (tests at different compressor speeds) in its certified pairing.

Mitsubishi Electric · mini-split heat pump

SUZ-AK48NLHZ is in the certified data as of Sep 19, 2026.

Certified heating and cooling

Heating at 47°F

60,000

52,000 at 17°F

52,000 at 5°F

Btu/h, certified

1.90 COP at 5°F

Cooling at 95°F

48,000

Btu/h, certified

EER2 9.4 at 95°F

SEER2 18.1

Heating and cooling by outdoor temperature

Certified heating at 5, 17, and 47°F and cooling at 95°F for SUZ-AK48NLHZ, by outdoor temperature Heating: 52,000 Btu/h at 5°F, 52,000 Btu/h at 17°F, 60,000 Btu/h at 47°F. Cooling: 48,000 Btu/h at 95°F. The bars start at zero. Median of 4-ton mini-split models: 42,000 Btu/h at 5°F, 38,000 Btu/h at 17°F, 49,000 Btu/h at 47°F, 48,000 Btu/h at 95°F. 0 20,000 40,000 60,000 Btu/h 52,000 5°F 52,000 17°F 60,000 47°F 48,000 95°F Outdoor temperature (°F)
  • Heating output
  • Cooling output
  • Median of 4-ton mini-split models
  • Example heating load
  • Example cooling load
  • Frosting range, 17 to 45°F

This pairing delivers 60,000 Btu/h of heat at 47°F, 52,000 Btu/h at 17°F, and 52,000 Btu/h at 5°F, 87% of its 47°F rating. It delivers 48,000 Btu/h of cooling at 95°F. At 5°F that is 10,000 Btu/h above the example heating load of 42,000 Btu/h; at 95°F it is 27,000 Btu/h above the example cooling load of 21,000 Btu/h.

Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 4-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.

The dashed lines are example loads for a typical area of about 1,750 sq ft where winters reach 5°F: heating runs from 42,000 Btu/h at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 21,000 Btu/h at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.

Calculate heating and cooling for your house

AHRI certificate 217121936 · listed by Mitsubishi Electric · certified May 2, 2025 · 1 pairing carries these values

All rebate programs and their published thresholds

Certified output and power use

Certified output for the selected pairingThe four bars share one scale. The comparison is with the median of 4-ton mini-split models. Heating tests run at 70°F indoors. The cooling test runs at 80°F indoors.
Outdoor temperature Certified outputBtu/h One scale vs class median COPat 5°F
5°Ffull speed 52,00015.24 kW +24% 1.90
17°Ffull speed 52,00015.24 kW +37% NR
47°Fnormal speed 60,00017.58 kW +22% NR
95°Fcooling, full load 48,00014.07 kW — NR

EER2 9.4 in that test. SEER2 18.1 over the modeled cooling season.

Power use at each temperature

Electrical input in the 5°F full-speed test
8.02kW
Electrical input in the 95°F cooling test
5.11kW
Seasonal average heating COP
2.49

These exclude backup resistance heat.

Updated Sep 19, 2026 · Methodology

How it compares with other 48,000 Btu heat pumps

4-ton mini-split models

This pairing at 5°F
52,000 Btu/h
This unit at 5°F median across its pairings
52,000 Btu/h
Median of 4-ton mini-split models at 5°F
42,000 Btu/h
Models in this group
321

This unit is above 98% of them, at number 7 of 321 by heat at 5°F. The middle half of the group runs 37,000 to 47,500 Btu/h.

This size class is defined by cooling capacity, so cooling is not compared here.

Closest models by heat at 5°F

Every 48,000 Btu (4-ton) unit, ranked by cooling efficiency, then heating efficiency

Certified values for SUZ-AK48NLHZ

1 pairing · 1 AHRI certificate

This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.

Certified values for SUZ-AK48NLHZ
This pairingAll pairings
Heating
Heat output at 47°F normal speed 60,000 Btu/h 60,000 Btu/h
Heat output at 17°F full speed 52,000 Btu/h 52,000 Btu/h
Heat output at 5°F full speed 52,000 Btu/h 52,000 Btu/h
Heat output below 5°F NR NR
Cold output 5°F output as a % of the 47°F rating 87%
COP at 5°F full speed 1.90 1.90
HSPF2 Region IV 8.5 8.5
Cooling
Cooling capacity at 95°F full-load test 48,000 Btu/h 48,000 Btu/h
EER2 at 95°F 9.4 9.4
SEER2 cooling season 18.1 18.1
Cooling at other temperatures NR NR
Equipment and listing
Refrigerant R-454B
Compressor Variable speed
Indoor unit SVZ-AP48NL*** 1 indoor unit
FurnaceNo furnace None
Cold-climate designation EPA's designation, as published Yes On every pairing
ENERGY STAR Most Efficient EPA's designation, as published No On no pairings
Where it is sold US and Canada US and Canada
Model string as certified SUZ-AK48NLHZ***

Pairings, by indoor-unit class

1 indoor unit · 1 certified pairing

One row per indoor unit certified with this outdoor unit.

Ductless indoor · 1 indoor unit

  1. SVZ-AP48NL*** (the pairing on screen) Mitsubishi Electric 52,000 Btu/hat 5°F, full speed

    1 pairing · 47°F 60,000 Btu/h · 95°F cooling 48,000 Btu/h · Cold output 87% · COP 1.90

Indoor units in the ductless indoor class
Indoor unit Brand At 5°FBtu/h · full speed At 47°FBtu/h · normal speed At 95°FBtu/h · cooling Cold output% of 47°F rating COP 5°Ffull speed Cold climate Pairings
SVZ-AP48NL*** (the pairing on screen) Mitsubishi Electric 52,000 60,000 48,000 87% 1.90 Yes 1

The share is heat output at 5°F divided by the 47°F rating.

Showing 1 of 1 indoor unit

Sold as, and units with identical certified values

Brands listing this model number

Model number as listed

Variants of the same model number

2 units in this group. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.

1 of 2 shown.

Other model numbers with identical certified values

2 units share this record. Basis: identical certified values in the certified data. This grouping is our inference, not a field in the certified data.

1 of 2 shown.

Product history

  • SUZ-AK48NLHZ first appeared in the certified data between March 2025 and May 2025.

History and definitions

History

First certified record
Most recent certified record
Measurements reported
May 2, 2025
Status
In the certified data

Field definitions

COP
Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
HSPF2
Heating efficiency over a typical season. Higher uses less electricity.
SEER2
Cooling efficiency over a typical season. Higher uses less electricity.
EER2
Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
Cold output
Heat output at 5°F as a percentage of the 47°F rating.
% of rating at 17°F
Heat output at 17°F as a percentage of the 47°F rating.

NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read

Cite or print this page

Heat Pump List, “SUZ-AK48NLHZ — certified heat output”. Certified figures dated , checked daily.
https://heatpumplist.com/model/suz-ak48nlhz