TMSCI7H4R18
TMSCI7H4R18 is in the certified data.
Its certified full-speed heating output at 5°F is 13,600–13,800 Btu/h3.99–4.04 kW, 76–77% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
Tosot · mini-split heat pump
TMSCI7H4R18 is in the certified data as of Oct 2, 2026. TMSCI7H4R18 changed its certified SEER2 on AHRI certificate 216723141 from 18.0 to 16.0 in the certified data between Oct 1, 2026 and Oct 2, 2026.
- 18,000 Btu (1.5-ton)
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
18,0005.28NR
No 47°F rating for this pairing.
14,5004.25NR at 17°F
13,7004.02NR at 5°F
Btu/hkW, certified
1.80NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 18,000 Btu/h5.28 kW of heat at 47°F, 14,500 Btu/h4.25 kW at 17°F, and 13,700 Btu/h4.02 kW at 5°F, 76% of its 47°F rating. It delivers 18,000 Btu/h5.28 kW of cooling at 95°F. At 5°F that is 300 Btu/h0.09 kW short of the example heating load of 14,000 Btu/h4.10 kW; at 95°F it is 11,000 Btu/h3.22 kW above the example cooling load of 7,000 Btu/h2.05 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 1.5-ton mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 600 sq ft where winters reach 5°F: heating runs from 14,000 Btu/h4.10 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 7,000 Btu/h2.05 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 216723142 · listed by TOSOT · certified Feb 24, 2025 · 1 pairing carries these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 13,7004.02 kW | −4% | 1.80 | |
| 17°Ffull speed | 14,5004.25 kW | −2% | NR | |
| 47°Fnormal speed | 18,0005.28 kW | 0% | NR | |
| 95°Fcooling, full load | 18,0005.28 kW | — | NR |
EER2 11.8 in that test. SEER2 19.0 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 2.23kW
- Electrical input in the 95°F cooling test
- 1.53kW
- Seasonal average heating COP
- 2.64
These exclude backup resistance heat.
How it compares with other 18,000 Btu heat pumps
1.5-ton mini-split models
- This pairing at 5°F
- 13,700 Btu/h4.02 kWNR
- This unit at 5°F median across its pairings
- 13,700 Btu/h4.02 kW
- Median of 1.5-ton mini-split models at 5°F
- 14,200 Btu/h4.16 kW
- Models in this group
- 1,110
This unit is above 39% of them, at number 678 of 1,110 by heat at 5°F. The middle half of the group runs 13,000 to 18,000 Btu/h.
Closest models by heat at 5°F
- GWHD(18)ND3NOGree · 13,700 Btu/h
- MUL18HP230V1R32AOGree · 13,700 Btu/h
- MUL19HP230V1R32AOGree · 13,700 Btu/h
- 048-C-TP-18K2V-23S-OUTDella · 13,600 Btu/h
- GMS18 PROGarvee · 13,600 Btu/h
- M4THM1918A12NAmeristar and RunTru · 13,600 Btu/h
Every 18,000 Btu (1.5-ton) unit, ranked by cooling efficiency, then heating efficiency
Certified values for TMSCI7H4R18
3 pairings · 3 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 18,000 Btu/h5.28 kWNR | 18,000 Btu/h5.28 kW |
| Heat output at 17°F full speed | 14,500 Btu/h4.25 kWNR | 14,000–15,000 Btu/h4.10–4.40 kW |
| Heat output at 5°F full speed | 13,700 Btu/h4.02 kWNR | 13,600–13,800 Btu/h3.99–4.04 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 76%NR | |
| COP at 5°F full speed | 1.80NR | 1.80–2.00 |
| HSPF2 Region IV | 9.0NR | 8.1–10.0 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 18,000 Btu/h5.28 kWNR | 16,000–18,000 Btu/h4.69–5.28 kW |
| EER2 at 95°F | 11.8NR | 11.0–12.0 |
| SEER2 cooling season | 19.0NR | 16.0–21.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-32 | |
| Compressor | Variable speed | |
| Indoor unit | None listed | None |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On some pairings |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | TMSCI7H4R18 | |
Pairings, by indoor-unit class
3 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor
-
None listed (the pairing on screen) TOSOT 13,700 Btu/h4.02 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| None listed (the pairing on screen) | TOSOT | 13,7004.02 | 18,0005.28 | 18,0005.28 | 76% | 1.86 | Yes | 3 |
Sold as, and units with identical certified values
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
Product history
- TMSCI7H4R18 changed its certified SEER2 on AHRI certificate 216723141 from 18.0 to 16.0 in the certified data between Oct 1, 2026 and Oct 2, 2026.
- TMSCI7H4R18 changed its certified EER2 on AHRI certificate 216723141 from 11.7 to 11.0 in the certified data between Oct 1, 2026 and Oct 2, 2026.
- TMSCI7H4R18 changed its certified cooling capacity at 95°F on AHRI certificate 216723141 from 18,000 Btu/h to 16,000 Btu/h in the certified data between Oct 1, 2026 and Oct 2, 2026.
- TMSCI7H4R18 first appeared in the certified data between November 2024 and February 2025.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Feb 24, 2025
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read