TWH09AD32AO
TWH09AD32AO is in the certified data.
Its certified full-speed heating output at 5°F is 9,000–11,500 Btu/h2.64–3.37 kW, 86–108% of its 47°F rating (tests at different compressor speeds), depending on the pairing.
Tosot · mini-split heat pump
TWH09AD32AO is in the certified data as of Sep 19, 2026.
- 9,000 Btu
- Mini-split
- Variable speed
- US and Canada
Certified heating and cooling
Heating at 47°F
10,5003.08NR
No 47°F rating for this pairing.
8,9002.61NR at 17°F
10,0002.93NR at 5°F
Btu/hkW, certified
1.75NR COP at 5°F
Heating and cooling by outdoor temperature
This pairing delivers 10,500 Btu/h3.08 kW of heat at 47°F, 8,900 Btu/h2.61 kW at 17°F, and 10,000 Btu/h2.93 kW at 5°F, 95% of its 47°F rating. It delivers 9,100 Btu/h2.67 kW of cooling at 95°F. At 5°F that is 2,500 Btu/h0.73 kW above the example heating load of 7,500 Btu/h2.20 kW; at 95°F it is 5,600 Btu/h1.64 kW above the example cooling load of 3,500 Btu/h1.03 kW.
Each bar is a separate certified test, drawn at its outdoor temperature, starting at zero. The 47°F figure is at normal speed; the 17 and 5°F figures are at full speed. The short dark line on each bar is the median of 9,000 Btu mini-split models, one value per model. The shaded 17 to 45°F band is the frosting range: the outdoor coil can frost, and the unit pauses to defrost.
The dashed lines are example loads for a typical area of about 300 sq ft where winters reach 5°F: heating runs from 7,500 Btu/h2.20 kW at 5°F to 0 at 65°F, and cooling runs from 0 at 65°F to 3,500 Btu/h1.03 kW at 95°F, at 1,000 sq ft per ton. A house in a hot climate or with large west-facing windows can need twice as much cooling. They are examples, not your building.
AHRI certificate 218001444 · listed by TOSOT · certified Jun 13, 2026 · 1 pairing carries these values
Rebates where you live
A utility program is for that utility's customers.
Choose location
Threshold comparisons use the unit’s certified figures across its pairings. Programs also set service-area, installation, and product-list requirements.
Certified output and power use
| Outdoor temperature | Certified outputBtu/h | One scale | vs class median | COPat 5°F |
|---|---|---|---|---|
| 5°Ffull speed | 10,0002.93 kW | +30% | 1.75 | |
| 17°Ffull speed | 8,9002.61 kW | +11% | NR | |
| 47°Fnormal speed | 10,5003.08 kW | +5% | NR | |
| 95°Fcooling, full load | 9,1002.67 kW | — | NR |
EER2 15.3 in that test. SEER2 23.3 over the modeled cooling season.
Power use at each temperature
- Electrical input in the 5°F full-speed test
- 1.67kW
- Electrical input in the 95°F cooling test
- 0.59kW
- Seasonal average heating COP
- 2.78
These exclude backup resistance heat.
How it compares with other 9,000 Btu heat pumps
9,000 Btu mini-split models
- This pairing at 5°F
- 10,000 Btu/h2.93 kWNR
- This unit at 5°F median across its pairings
- 10,000 Btu/h2.93 kW
- Median of 9,000 Btu mini-split models at 5°F
- 7,700 Btu/h2.26 kW
- Models in this group
- 894
This unit is above 80% of them, at number 179 of 894 by heat at 5°F. The middle half of the group runs 7,000 to 9,500 Btu/h.
Closest models by heat at 5°F
- GS09HP230V1RYOGree · 10,000 Btu/h
- MHSZ109DAConforto and EMI · 10,000 Btu/h
- MSH093E23MCAAFranklin and Goodman · 10,000 Btu/h
- GWH09AGCXD-A3DNA1A/OGree · 9,900 Btu/h
- 1U09EH2HEHaier · 9,800 Btu/h
- CU-XE9WKUAPanasonic · 9,700 Btu/h
Every 9,000 Btu unit, ranked by cooling efficiency, then heating efficiency
Certified values for TWH09AD32AO
5 pairings · 5 AHRI certificates
This pairing is the one shown above. Under all pairings, a single figure means every pairing agrees and a range means the pairing decides.
| This pairing | All pairings | |
|---|---|---|
| Heating | ||
| Heat output at 47°F normal speed | 10,500 Btu/h3.08 kWNR | 10,500–10,600 Btu/h3.08–3.11 kW |
| Heat output at 17°F full speed | 8,900 Btu/h2.61 kWNR | 8,900–12,000 Btu/h2.61–3.52 kW |
| Heat output at 5°F full speed | 10,000 Btu/h2.93 kWNR | 9,000–11,500 Btu/h2.64–3.37 kW |
| Heat output below 5°F | NR | NR |
| Cold output 5°F output as a % of the 47°F rating | 95%NR | |
| COP at 5°F full speed | 1.75NR | 1.75–2.11 |
| HSPF2 Region IV | 9.5NR | 9.5–11.2 |
| Cooling | ||
| Cooling capacity at 95°F full-load test | 9,100 Btu/h2.67 kWNR | 9,100 Btu/h2.67 kW |
| EER2 at 95°F | 15.3NR | 13.65–16.8 |
| SEER2 cooling season | 23.3NR | 22.3–30.0 |
| Cooling at other temperatures | NR | NR |
| Equipment and listing | ||
| Refrigerant | R-32 | |
| Compressor | Variable speed | |
| Indoor unit | TEH09D32AI | 5 indoor units |
| Furnace | No furnace | None |
| Cold-climate designation EPA's designation, as published | Yes | On every pairing |
| ENERGY STAR Most Efficient EPA's designation, as published | Yes | On every pairing |
| Where it is sold | US and Canada | US and Canada |
| Model string as certified | TWH09AD32AO | |
Pairings, by indoor-unit class
5 indoor units · 5 certified pairings
One row per indoor unit certified with this outdoor unit.
Ductless indoor · 5 indoor units
-
TEH09D32AI (the pairing on screen) TOSOT 10,000 Btu/h2.93 kWat 5°F, full speed
-
TFH09D32AI (the pairing on screen) TOSOT 9,200 Btu/h2.70 kWat 5°F, full speed
-
TLH09D32AI (the pairing on screen) TOSOT 9,000 Btu/h2.64 kWat 5°F, full speed
-
TTH09D32AI (the pairing on screen) TOSOT 10,500 Btu/h3.08 kWat 5°F, full speed
-
TWH09AD32AI (the pairing on screen) TOSOT 11,500 Btu/h3.37 kWat 5°F, full speed
| Indoor unit | Brand | At 5°FBtu/hkW · full speed | At 47°FBtu/hkW · normal speed | At 95°FBtu/hkW · cooling | Cold output% of 47°F rating | COP 5°Ffull speed | Cold climate | Pairings |
|---|---|---|---|---|---|---|---|---|
| TEH09D32AI (the pairing on screen) | TOSOT | 10,0002.93 | 10,5003.08 | 9,1002.67 | 95% | 1.75 | Yes | 1 |
| TFH09D32AI (the pairing on screen) | TOSOT | 9,2002.70 | 10,5003.08 | 9,1002.67 | 88% | 1.80 | Yes | 1 |
| TLH09D32AI (the pairing on screen) | TOSOT | 9,0002.64 | 10,5003.08 | 9,1002.67 | 86% | 1.75 | Yes | 1 |
| TTH09D32AI (the pairing on screen) | TOSOT | 10,5003.08 | 10,5003.08 | 9,1002.67 | 100% | 1.90 | Yes | 1 |
| TWH09AD32AI (the pairing on screen) | TOSOT | 11,5003.37 | 10,6003.11 | 9,1002.67 | 108% | 2.11 | Yes | 1 |
Sold as, and units with identical certified values
What affects the price
We don't have prices. These things drive the cost.
- The size of the unit, and the indoor equipment on the same certificate.
- Whether existing ductwork is reused, altered, or replaced.
- The electrical work: a circuit, a disconnect, and sometimes a panel change.
- Refrigerant line length and how the outdoor unit is mounted.
- Permits and inspection, which vary by municipality.
- Removing and disposing of the old equipment.
- Local labor rates and how busy the season is.
- Rebates and tax credits, which change and have deadlines.
History and definitions
History
- First certified record
- Most recent certified record
- Measurements reported
- Jun 13, 2026
- Status
- In the certified data
Field definitions
- COP
- Heat delivered for each unit of electricity used. A COP of 2.5 gives 2.5 times the heat of an electric baseboard heater.
- HSPF2
- Heating efficiency over a typical season. Higher uses less electricity.
- SEER2
- Cooling efficiency over a typical season. Higher uses less electricity.
- EER2
- Cooling output divided by electrical input in the 95°F full-load test, in Btu/h per watt.
- Cold output
- Heat output at 5°F as a percentage of the 47°F rating.
- % of rating at 17°F
- Heat output at 17°F as a percentage of the 47°F rating.
NR not in the certified dataNC not cold-climate certifiedSP single pairing onlyVP varies by pairing; see the pairings tableWD withdrawn since the certified data was last read